OS
← Component Tree

SCR (Selective Catalytic Reduction)

high
Parent: Exhaust System

Components for this Group (1)

WIN-GD SCR Reactor (for diesel mode Tier III)
WIN-GD X-DF · Supplier: HUG Engineering / Yara Marine
20w
Common Failures:
  • • Catalyst deactivation from sulfur poisoning (HFO)
  • • Urea crystallization in piping
  • • Reactor thermal shock
  • • Ammonia slip
Service: Only needed for Tier III in diesel mode (gas mode is inherently Tier III). SCR bypass in gas mode.
Weight: 12000.0 kg