OS
← Safety Systems

Enclosed Space Entry Equipment

critical IMO Required
Equipment kit for safe enclosed space entry per SOLAS XI-1/7 and MSC.1/Circ.1401.
4000h
Service Interval

Typical Manufacturers

Dräger MSA

Known Models (2)

Dräger Dräger Confined Space Entry Kit
Dräger Dräger Confined Space Entry Kit
Complete entry set with gas monitor, harness, rescue tripod · Marine Equipment
Common Failures:
  • • Gas monitor sensor expiry
  • • Tripod locking pin wear
  • • Rescue winch cable kinking
Service: Gas monitor calibration every 6 months. Tripod and winch load test annually. Harness inspection per EN 365.
Spares: Dräger: Sicherheitsausrüstung per SOLAS-Mindestbestand. Lead time: 2-4 Wochen.
MSA MSA Confined Space Entry Kit
MSA MSA Confined Space Entry Kit
Entry set with Altair 5X, harness, tripod · Marine Equipment
Common Failures:
  • • Multi-gas sensor cross-sensitivity
  • • Fall arrest indicator deployment
  • • Winch handle mechanism jam
Service: Sensor replacement per MSA schedule. Annual load test of tripod and winch.
Spares: MSA: Sicherheitsausrüstung per SOLAS-Mindestbestand. Lead time: 2-4 Wochen.