OS
← Pumps

General Service Pump

medium
Multi-purpose pump for tank cleaning, deck wash, etc.
8000h
Service Interval
20 yr
Typical Lifetime

Typical Manufacturers

IMO Shinko Azcue

Known Models (3)

Azcue AN 50-250
Azcue AN 50-250
50 m3/h · 11.0 kW · Seawater/Freshwater
Common Failures:
  • • Corrosion
  • • Seal failure
  • • Cavitation
Service: Can handle various media; flush after seawater use if switching to FW.
Spares: Azcue: Ersatzteile per Hersteller-Ersatzteilliste. Mechanische Dichtungen und Laufräder an Bord vorhalten. Lead time: 2-6 Wochen je nach Hersteller.
IMO ACE 032K3 NVBP
IMO ACE 032K3 NVBP
60 m3/h · 15.0 kW · Seawater/Freshwater
Common Failures:
  • • Seal wear
  • • Impeller erosion
  • • Coupling misalignment
Service: Versatile centrifugal; can serve as backup bilge/ballast.
Spares: IMO: Ersatzteile per Hersteller-Ersatzteilliste. Mechanische Dichtungen und Laufräder an Bord vorhalten. Lead time: 2-6 Wochen je nach Hersteller.
Shinko GVD 250M
Shinko GVD 250M
80 m3/h · 18.5 kW · Seawater/Freshwater · Centrifugal Pump
Common Failures:
  • • Mechanical seal leak
  • • Impeller pitting
  • • Bearing noise
Service: Dual-purpose pump; ensure correct valve lineup before starting.
Spares: Shinko: Ersatzteile per Hersteller-Ersatzteilliste. Mechanische Dichtungen und Laufräder an Bord vorhalten. Lead time: 2-6 Wochen je nach Hersteller.
✔ Pros
  • • Versatile for multiple applications on a vessel
  • • Reliable performance in general service duties
  • • Compact design for efficient space utilization
⚠ Cons
  • • Prone to mechanical seal leaks if not properly maintained
  • • Impeller pitting can occur under abrasive conditions
  • • Bearing noise may indicate wear, requiring timely intervention
Typical Vessels: TankerContainerBulk CarrierGeneral Cargo
Decision Guide: Choose if you need a versatile pump for general service duties and are prepared for regular maintenance. Avoid if you prioritize a pump with a proven track record of minimal mechanical seal issues.
Use Cases: Typically deployed in engine rooms, cargo pumps, and other areas requiring reliable fluid transfer. Often used in applications where space is limited and the pump must serve multiple purposes.