Inert Gas Generator (Tanker)
critical
IMO Required
55 Modelle gesamt
Generates inert gas for tanker cargo tank atmosphere control
4000h
Service Interval
5 yr
Class Survey
20 yr
Typical Lifetime
Typical Manufacturers
Smit
Aalborg
12 Hersteller · 55 Modelle
🏭
Saacke
18 ✓ 18 verifiziert⚙️
GCU evo (Gas Combustion Unit Evolution)
✓ verifiziert
verified_specs: {'Capacity Range': '0.4 - 4.5 t/h methane', 'Burner Capacity': '5.5 - 63 MW', 'Combustion Method': '100% free-flow solution without compressor', 'Operating Pressure': '0.15 bar', 'Combustion Temperature': '~600°C', 'Material Temperature Limit': '1,100°C', 'NOx Emissions': '60-80 mg/m³', 'CO Emissions': '150 mg/m³', 'Turndown Ratio': '1:10', 'Installation': 'Deck-mounted, no special foundation required'}
application: LNG Tanker - Boil-off Gas Combustion
model_source: https://www.saacke.com/en/marine/products/gas-combustion-units/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
GCU compact (Gas Combustion Unit Standard)
✓ verifiziert
verified_specs: {'Capacity Range': '0.15 - 6.5 t/h methane', 'Air Excess': '250%', 'Flame Temperature': 'Low (reduced heat radiation)', 'Installation Options': 'Vertical and horizontal', 'Pilot Burner': 'Oil-fired for continuous operation', 'Combustion Type': 'Air-cooled steel combustion chamber', 'Maintenance Access': 'Via chimney shaft', 'Design Feature': 'Rainproof design for corrosion protection'}
application: LNG Tanker - Boil-off Gas Combustion
model_source: https://www.saacke.com/en/marine/products/gas-combustion-units/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
FMB-VS (Fired Marine Boiler - Vertical Side-fired)
✓ verifiziert
verified_specs: {'Capacity': 'Up to 5 t/h', 'Design Pressure': '1.2 MPa', 'Configuration': 'Vertical, side-fired', 'Heat Transfer Method': 'Plate furnace with rifled plain smoke tubes', 'Furnace Type': 'Spherical fire plate for vibration resistance', 'Application': 'All ship types including tankers'}
application: Tanker - Steam Generation & Cargo Heating
model_source: https://www.saacke.com/en/marine/products/marine-boilers/fired-ship-boiler-fmb/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
FMB-VM (Fired Marine Boiler - Vertical Medium)
✓ verifiziert
verified_specs: {'Capacity': '6 - 25 t/h', 'Design Pressure': '1.0 MPa', 'Configuration': 'Vertical water tube', 'Furnace Type': 'Cylindrical membrane wall', 'Heat Transfer': 'Radiation via membrane wall, convection via pin elements or rifled smoke tubes'}
application: Tanker - Steam Generation & Cargo Heating
model_source: https://www.saacke.com/en/marine/products/marine-boilers/fired-ship-boiler-fmb/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
FMB-VL (Fired Marine Boiler - Vertical Large)
✓ verifiziert
verified_specs: {'Capacity': '14 - 45 t/h', 'Design Pressure': '1.8 MPa', 'Configuration': 'Vertical water tube', 'Furnace Type': 'Cylindrical membrane wall', 'Water Circulation': 'Natural via external downpipes', 'Heat Transfer': 'Radiant in furnace, convection via pin elements or smoke tubes'}
application: Tanker - Steam Generation & Cargo Heating
model_source: https://www.saacke.com/en/marine/products/marine-boilers/fired-ship-boiler-fmb/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
FMB-VD (Fired Marine Boiler - D-Type)
✓ verifiziert
verified_specs: {'Capacity': '30 - 110 t/h', 'Design Pressure': '2.5 MPa', 'Configuration': 'Top-fired D-type water tube', 'Furnace Design': 'Classic membrane wall furnace', 'Heat Transfer': 'Radiant in furnace, convection via special pin tubes', 'Steam Output': 'Saturated or with optional superheater', 'Maintenance': 'Steam-operated soot blowers'}
application: Tanker - Steam Generation & Large Capacity Applications
model_source: https://www.saacke.com/en/marine/products/marine-boilers/fired-ship-boiler-fmb/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
FMB-HF (Fired Marine Boiler - Horizontal Three-Pass)
✓ verifiziert
verified_specs: {'Capacity': 'Up to 10 t/h', 'Design Pressure': '1.2 MPa', 'Configuration': 'Horizontal three-pass', 'Design Benefit': 'Maximum energy efficiency with compact design', 'Maintenance': 'Accessible rear hatches for flue gas pipe cleaning'}
application: Tanker - High-Efficiency Steam Generation
model_source: https://www.saacke.com/en/marine/products/marine-boilers/fired-ship-boiler-fmb/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
CMB-VF-LONOX (Combination Marine Boiler - Vertical with LONOX)
✓ verifiziert
verified_specs: {'Oil-fired Capacity': 'Up to 18 t/h (13 t/h LONOX version)', 'Design Pressure': '1.0 MPa', 'Configuration': 'Vertical', 'Firing Type': 'Dual - exhaust gas and oil', 'Special Feature': 'Optional flue gas recirculation for ultra-low NOx', 'Design Benefit': '2-in-1 solution for varying steam requirements'}
application: Tanker - Combined Oil & Exhaust Gas Firing with Low NOx
model_source: https://www.saacke.com/en/marine/products/marine-boilers/combination-ship-boiler-with-additional-fire/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
CMB-VS (Combination Marine Boiler - Vertical Side-fired)
✓ verifiziert
verified_specs: {'Oil-fired Capacity': 'Up to 5 t/h', 'Flue Gas': 'As required', 'Design Pressure': '1.2 MPa', 'Configuration': 'Vertical', 'Design Feature': 'Curved cover plate for stability'}
application: Tanker - Combined Oil & Exhaust Gas Firing
model_source: https://www.saacke.com/en/marine/products/marine-boilers/combination-ship-boiler-with-additional-fire/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
CMB-HF (Combination Marine Boiler - Horizontal Three-Pass)
✓ verifiziert
verified_specs: {'Oil-fired Capacity': 'Up to 10 t/h', 'Flue Gas': 'As required', 'Design Pressure': '1.2 MPa', 'Configuration': 'Horizontal', 'Maintenance': 'Easy access via rear hatches'}
application: Tanker - Combined Oil & Exhaust Gas Firing
model_source: https://www.saacke.com/en/marine/products/marine-boilers/combination-ship-boiler-with-additional-fire/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
EMB-HST / EME-HST (Exhaust Gas Marine Boiler/Economizer - Horizontal Smoke Tube)
✓ verifiziert
verified_specs: {'Type': 'Horizontal smoke tube', 'Design Pressure': 'Up to 2.2 MPa', 'Boiler Version (EMB-HST)': 'Independent steam space', 'Economizer Version (EME-HST)': 'Requires connection to fired boiler', 'Silencer Function': 'Yes, integrated', 'Dry Running': 'Emergency-suitable', 'Cleaning': 'Plain smoke tubes, easy to clean'}
application: Tanker - Exhaust Gas Heat Recovery
model_source: https://www.saacke.com/en/marine/products/marine-boilers/ship-exhaust-gas-economizer/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
EMB-VST / EME-VST (Exhaust Gas Marine Boiler/Economizer - Vertical Smoke Tube)
✓ verifiziert
verified_specs: {'Type': 'Vertical smoke tube', 'Design Pressure': 'Up to 2.2 MPa', 'Configuration': 'Autonomous operation with separate steam range', 'Noise Reduction': 'Sound-absorbing function', 'Emergency Function': 'Dry-run capable', 'Silencer': 'Integrated'}
application: Tanker - Exhaust Gas Heat Recovery
model_source: https://www.saacke.com/en/marine/products/marine-boilers/ship-exhaust-gas-economizer/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
EMB-VFT / EME-VFT (Exhaust Gas Marine Boiler/Economizer - Vertical Forced Circulation)
✓ verifiziert
verified_specs: {'Type': 'Vertical with forced circulation', 'Design Pressure': 'Up to 2.2 MPa', 'Design': 'Modular design for maintenance', 'Maintenance': 'Each module independently removable', 'Configuration': 'Isolatable modules via horizontal collectors', 'Dry Running': 'Emergency-suitable', 'Silencer': 'Integrated sound-absorbing'}
application: Tanker - Exhaust Gas Heat Recovery with Forced Circulation
model_source: https://www.saacke.com/en/marine/products/marine-boilers/ship-exhaust-gas-economizer/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
WHRU (Waste Heat Recovery Unit)
✓ verifiziert
verified_specs: {'Design': 'Compact and robust', 'Installation': 'Flexible, usually in chimney without major modifications', 'Heat Exchanger Type': 'Two-pass design', 'Fuel Savings': 'Over 80% fuel consumption reduction', 'Power Consumption': '6x lower than competitive products', 'Space Requirement': 'Minimal', 'Dry Operation': 'Unlimited capability', 'Commissioning': 'Within one working day'}
application: Tanker - Main & Auxiliary Engine Exhaust Heat Recovery
model_source: https://www.saacke.com/en/marine/products/waste-heat-recovery-unit/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
SKVG (Rotary Cup Atomizer Burner - Duoblock)
✓ verifiziert
verified_specs: {'Capacity Range': '1.7 - 17 MW', 'Configuration': 'Duoblock rotary cup atomizer', 'Fuel Flexibility': 'Heavy Fuel Oil (up to 700 cSt/50°C), Marine Diesel Oil, Natural Gas', 'Control Range': '1:8 for both liquid and gaseous fuels', 'Application': 'All types of marine boilers, all ship types including tankers'}
application: Tanker Marine Boilers - Oil & Gas Firing
model_source: https://www2.saacke.com/products/burners/skvg/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
SKV-A (Rotary Cup Atomizer Burner - Duoblock)
✓ verifiziert
verified_specs: {'Configuration': 'Duoblock rotary cup atomizer', 'Fuel Capacity': 'Heavy Fuel Oil up to 700 cSt/50°C', 'Fuel Types': 'Marine Diesel Oil, Marine Gas Oil, Natural Gas', 'Application': 'All kinds of marine boilers, all ship types including tankers', 'Design': 'Proven duoblock design for reliability'}
application: Tanker Marine Boilers - Multi-Fuel Firing
model_source: https://www.saacke.com/en/marine/products/marine-burners/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
SKVJ-M (Rotary Cup Atomizer Burner - Monoblock)
✓ verifiziert
verified_specs: {'Configuration': 'Monoblock rotary cup atomizer', 'Capacity': '0.95 - 6.8 MW', 'Control Range': '1:7', 'Fuel Types': 'Heavy Fuel Oil (up to 700 cSt/50°C), Marine Diesel Oil, Marine Gas Oil', 'Design Focus': 'Easy installation, operation, and maintenance', 'Application': 'Smaller sized marine boilers'}
application: Smaller Tanker Marine Boilers - Multi-Fuel Firing
model_source: https://www.saacke.com/en/marine/products/marine-burners/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
EGCS-HM (Exhaust Gas Cleaning System - Hybrid Multistream Scrubber)
✓ verifiziert
verified_specs: {'System Type': 'Hybrid multistream scrubber', 'Configuration Options': '1-tower and 2-tower versions', 'SOx Removal Rate': 'Up to 99%', 'Pollutant Target': 'SOx and solid particles', 'Connection': 'Main engines, auxiliary engines, and boilers', 'Flexibility': 'Different performance capacities, flexibly adjustable', 'Monitoring': 'EGCS-Monitor for transmission of plant data'}
application: Tanker - Emissions Reduction (SOx, Particulates)
model_source: https://www.saacke.com/en/marine/products/marine-boilers/ship-exhaust-gas-economizer/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
🏭
Maritime Protection (Survitec)
17 ✓ 17 verifiziert⚙️
MPG-400
✓ verifiziert
verified_specs: {'Type': 'Standard Inert Gas Generator', 'Capacity': '500 m³/h', 'Oxygen Content': '3% typical (@ 25°C)', 'Power Consumption': '7.5 kW', 'Dimensions': '1830 x 800 x 2225 mm', 'Weight': '1150 kg', 'Fuel Type': 'HFO/MGO/MDO/Natural Gas'}
application: Oil/Product Tanker Inerting
model_source: https://www.maritimeinformed.com/survitec-mpg-400-inert-gas-systems-technical-details.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
MPG-700
✓ verifiziert
verified_specs: {'Type': 'Standard Inert Gas Generator', 'Capacity Range': '500-2200 m³/h', 'Oxygen Content': '3% typical (@ 25°C)', 'Power Consumption': '7.5-33 kW', 'Dimensions': '3000 x 1000 x 2800 mm', 'Weight': '1500 kg', 'Fuel Type': 'HFO/MGO/MDO/Natural Gas'}
application: Oil/Product Tanker Inerting
model_source: https://www.maritimeinformed.com/survitec-mpg-700-inert-gas-systems-technical-details.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
MPG-800
✓ verifiziert
verified_specs: {'Type': 'Standard Inert Gas Generator', 'Capacity Range': '2200-3200 m³/h', 'Oxygen Content': '3% typical (@ 25°C)', 'Power Consumption': '33-48 kW', 'Dimensions': '3300 x 1100 x 2800 mm', 'Weight': '1900 kg', 'Fuel Type': 'HFO/MGO/MDO/Natural Gas'}
application: Oil/Product Tanker Inerting
model_source: https://www.maritimeinformed.com/survitec-mpg-800-inert-gas-systems-technical-details.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
MPG-900
✓ verifiziert
verified_specs: {'Type': 'Standard Inert Gas Generator', 'Capacity Range': '3200-4500 m³/h', 'Oxygen Content': '3% typical (@ 25°C)', 'Power Consumption': '48-67.5 kW', 'Dimensions': '3600 x 1200 x 4000 mm', 'Weight': '2200 kg', 'Fuel Type': 'HFO/MGO/MDO/Natural Gas'}
application: Oil/Product Tanker Inerting
model_source: https://www.maritimeinformed.com/survitec-mpg-900-inert-gas-systems-technical-details.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
MPG-900-124
✓ verifiziert
verified_specs: {'Type': 'Dry Inert Gas Generator', 'Capacity Range': '3200-4500 m³/h', 'Oxygen Content': '1%', 'Dew Point': '-45°C initial, -60 to -65°C operational', 'Power Consumption': '246-330 kW', 'Weight': '9600 kg', 'Features': '100% automatic control, continuous dryer regeneration'}
application: Oil/Product Tanker Inerting (Dry IGG)
model_source: https://www.maritimeinformed.com/survitec-mpg-900-124-inert-gas-systems-technical-details.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
MPG-1000
✓ verifiziert
verified_specs: {'Type': 'Standard Inert Gas Generator', 'Capacity Range': '4500-5700 m³/h', 'Oxygen Content': '3% typical (@ 25°C)', 'Power Consumption': '67.5-85 kW', 'Dimensions': '4000 x 1400 x 4500 mm', 'Weight': '2500 kg', 'Fuel Type': 'HFO/MGO/MDO/Natural Gas'}
application: Oil/Product Tanker Inerting
model_source: https://www.maritimeinformed.com/survitec-mpg-1000-inert-gas-systems-technical-details.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
MPG-1000-154
✓ verifiziert
verified_specs: {'Type': 'Dry Inert Gas Generator', 'Capacity Range': '4500-5700 m³/h', 'Oxygen Content': '1%', 'Dew Point': '-45°C initial, -60 to -65°C operational', 'Power Consumption': '335-387 kW', 'Weight': '11200 kg', 'Features': '50% weight/footprint reduction vs conventional systems'}
application: Oil/Product Tanker Inerting (Dry IGG)
model_source: https://www.maritimeinformed.com/survitec-mpg-1000-154-inert-gas-systems-technical-details.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
MPG-1100-154
✓ verifiziert
verified_specs: {'Type': 'Dry Inert Gas Generator', 'Capacity Range': '5700-6800 m³/h', 'Oxygen Content': '1%', 'Dew Point': '-45°C initial, -60 to -65°C operational', 'Power Consumption': '387-456 kW', 'Weight': '12600 kg', 'Features': '100% automatic control, compact design'}
application: Oil/Product Tanker Inerting (Dry IGG)
model_source: https://www.maritimeinformed.com/survitec-mpg-1100-154-inert-gas-systems-technical-details.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
MPG-1300
✓ verifiziert
verified_specs: {'Type': 'Standard Inert Gas Generator', 'Capacity Range': '6800-10500 m³/h', 'Oxygen Content': '3% typical (@ 25°C)', 'Power Consumption': '102-157 kW', 'Dimensions': '5400 x 1800 x 4800 mm', 'Weight': '5000 kg', 'Fuel Type': 'HFO/MGO/MDO/Natural Gas'}
application: Oil/Product Tanker Inerting
model_source: https://www.maritimeinformed.com/survitec-mpg-1300-inert-gas-systems-technical-details.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
MPG-1300-174
✓ verifiziert
verified_specs: {'Type': 'Dry Inert Gas Generator', 'Capacity Range': '6800-9500 m³/h', 'Oxygen Content': '1%', 'Dew Point': '-45°C initial, -60 to -65°C operational', 'Power Consumption': '456-656 kW', 'Weight': '14800 kg', 'Features': '100% automatic, 50% weight/footprint reduction'}
application: Oil/Product Tanker Inerting (Dry IGG)
model_source: https://www.maritimeinformed.com/survitec-mpg-1300-174-inert-gas-systems-technical-details.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
MPG-1300-194
✓ verifiziert
verified_specs: {'Type': 'Dry Inert Gas Generator', 'Capacity Range': '9500-10500 m³/h', 'Oxygen Content': '1%', 'Dew Point': '-45°C initial, -60 to -65°C operational', 'Power Consumption': '656-692 kW', 'Weight': '16500 kg', 'Features': '100% automatic control, continuous dryer regeneration'}
application: Oil/Product Tanker Inerting (Dry IGG)
model_source: https://www.maritimeinformed.com/survitec-mpg-1300-194-inert-gas-systems-technical-details.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
MPG-1600
✓ verifiziert
verified_specs: {'Type': 'Standard Inert Gas Generator', 'Capacity Range': '10500-16000 m³/h', 'Oxygen Content': '3% typical (@ 25°C)', 'Power Consumption': '157-240 kW', 'Dimensions': '6000 x 2100 x 5025 mm', 'Weight': '7000 kg', 'Fuel Type': 'HFO/MGO/MDO/Natural Gas'}
application: Oil/Product Tanker Inerting
model_source: https://www.maritimeinformed.com/survitec-mpg-1600-inert-gas-systems-technical-details.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
MPG-1600-194
✓ verifiziert
verified_specs: {'Type': 'Dry Inert Gas Generator', 'Capacity Range': '10500-12000 m³/h', 'Oxygen Content': '1%', 'Dew Point': '-45°C initial, -60 to -65°C operational', 'Power Consumption': '692-746 kW', 'Weight': '21000 kg', 'Features': '50% weight/footprint reduction, MODBUS compatible'}
application: Oil/Product Tanker Inerting (Dry IGG)
model_source: https://www.maritimeinformed.com/survitec-mpg-1600-194-inert-gas-systems-technical-details.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
MPG-1800
✓ verifiziert
verified_specs: {'Type': 'Standard Inert Gas Generator', 'Capacity Range': '16000-18500 m³/h', 'Oxygen Content': '3% typical (@ 25°C)', 'Power Consumption': '240-280 kW', 'Dimensions': '7000 x 2100 x 5025 mm', 'Weight': '9000 kg', 'Fuel Type': 'HFO/MGO/MDO/Natural Gas'}
application: Oil/Product Tanker Inerting
model_source: https://survitecgroup.com/systems/mp-inert-gas-generator-solutions
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
MPG-1800-244
✓ verifiziert
verified_specs: {'Type': 'Dry Inert Gas Generator', 'Capacity Range': '16000-18500 m³/h', 'Oxygen Content': '1%', 'Dew Point': '-45°C initial, -60 to -65°C operational', 'Power Consumption': '932-1131 kW', 'Weight': '26600 kg', 'Features': '50% weight/footprint reduction, stainless steel SST 904 combustion chamber'}
application: Oil/Product Tanker Inerting (Dry IGG)
model_source: https://www.maritimeinformed.com/survitec-mpg-1800-244-inert-gas-systems-technical-details.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
MPG-1800-264
✓ verifiziert
verified_specs: {'Type': 'Dry Inert Gas Generator', 'Capacity Range': '18500-21000 m³/h', 'Oxygen Content': '1%', 'Dew Point': '-45°C initial, -60 to -65°C operational', 'Power Consumption': '1131-1365 kW', 'Weight': '28200 kg', 'Features': '100% automatic control, continuous dryer regeneration, SST 904 combustion chamber'}
application: Oil/Product Tanker Inerting (Dry IGG)
model_source: https://www.maritimeinformed.com/survitec-mpg-1800-264-inert-gas-systems-technical-details.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
MPG-700-084
✓ verifiziert
verified_specs: {'Type': 'Dry Inert Gas Generator', 'Capacity Range': '900-2000 m³/h', 'Oxygen Content': '1%', 'Dew Point': '-45°C initial, -60 to -65°C operational', 'Power Consumption': '38-181 kW', 'Weight': '7100 kg', 'Features': 'Automatic control, compact dry generator design'}
application: Oil/Product Tanker Inerting (Dry IGG)
model_source: https://www.maritimeinformed.com/survitec-mpg-700-084-inert-gas-systems-technical-details.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
🏭
Alfa Laval Smit
6 ✓ 6 verifiziert⚙️
Smit Gas FU (Smit Combustion)
✓ verifiziert
verified_specs: {'Capacity': '1,000-20,000 m³/h', 'Pressure': '0.15 or 0.25 bar(g)', 'Oxygen Content': '2-4%', 'Type': 'Low-pressure combustion-based', 'Burner Technology': 'Ultramizing® steam-atomizing, soot-free', 'Cooling': 'Seawater indirect cooling or Air-cooled (FU-type)'}
application: Oil Tanker, Chemical Tanker, Product Tanker
model_source: https://www.alfalaval.com/products/process-solutions/safety-solutions/inert-gas-system/smit-gas-combustion/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Smit Gas FIN (Smit Flue Gas)
✓ verifiziert
verified_specs: {'Capacity': '3,000-30,000 m³/h', 'Pressure': '0.1 bar(g)', 'Type': 'Saturated flue gas inert gas system', 'Fuel Source': 'Heavy Fuel Oil (HFO) boiler flue gas', 'Dew Point': 'Dry saturated', 'Introduced': 'Enhanced version 2004 with improved particle removal and compact design'}
application: Crude Oil Tanker, Product Tanker, FPS
model_source: https://www.alfalaval.com/products/process-solutions/safety-solutions/flue-gas-type-inert-gas-system/smit-flue-gas/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Smit LNG/LPG
✓ verifiziert
verified_specs: {'Capacity': '3,000-22,500 m³/h (up to 25,000 m³/h)', 'Pressure': '0.3-0.4 bar(g), Range 0.1-0.4 bar(g)', 'Oxygen Content': '0.5-1.0%', 'Dew Point': '-45°C to -65°C', 'Type': 'Low-pressure, low dew-point combustion-type with drying', 'Components': 'Generator, Cooler, Chiller, Dryer unit (modular)', 'Burner Technology': 'Ultramizing® with steam-atomizing and vaporizing burners', 'Fuel Types': 'DMX, DMA, DMB'}
application: LNG Carrier, LPG Carrier
model_source: https://www.alfalaval.com/products/process-solutions/safety-solutions/combustion-type-inert-gas-system/smit-lng/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Smit Combinert (FGIN)
✓ verifiziert
verified_specs: {'Capacity': '1,000-20,000 m³/h', 'Pressure': '0.13 bar(g)', 'Type': 'Dual-mode: Combustion + Flue Gas', 'Operating Modes': 'Combustion mode (FU) or Flue Gas mode (FIN) or simultaneous', 'Fuel Source for Flue Gas': 'Heavy Fuel Oil boiler exhaust', 'Oxygen Content': '2-4% (combustion mode)', 'Advantage': 'Saves fuel oil without compromising safety or reliability', 'Fuel Types': 'DMA, DMB, DMZ, HFO-fired boiler exhaust'}
application: Crude Oil Tanker, Product Tanker, FPSO
model_source: https://www.alfalaval.com/products/process-solutions/safety-solutions/inert-gas-system/smit-combinert/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Smit Portinert
✓ verifiziert
verified_specs: {'Type': 'Containerized combustion-type inert gas system', 'Base Technology': 'Smit Combustion (FU) modular design', 'Capacity': '1,000-20,000 m³/h (inherited from Smit Combustion)', 'Pressure': '0.15 or 0.25 bar(g)', 'Design Feature': 'Easy transport, placement and connection', 'Applications': 'Chemical tankers and product tankers', 'Burner Technology': 'Ultramizing® system - soot-free, complete combustion at partial loads (down to 25%)'}
application: Mobile/Containerized Inert Gas Generation (Tanker Support)
model_source: https://www.nauticexpo.com/prod/alfa-laval-mid-europe/product-30729-416309.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
AFEM (Automatic Fuel Efficiency Module)
✓ verifiziert
verified_specs: {'Type': 'Automatic fuel efficiency control module', 'Base System': 'Upgrades existing or new Smit Combustion systems', 'Fuel Savings': 'Up to 40% reduction in fuel consumption', 'Pilot Project Results': 'Average 30% fuel savings over 2-year trial (Navigazione Montanari)', 'Function': 'Automatic oxygen regulation to operate near IMO maximum limits', 'Operation Mode': 'Automatically adjusts burner capacity for cargo stripping and temporary discharge stops', 'Installation': 'Available as retrofit or as option for new installations'}
application: Retrofit upgrade for Smit Combustion inert gas systems
model_source: https://www.alfalaval.com/industries/marine-transportation/marine/marine-news/near-newsletter/alfa-laval-afem-for-smit-inert-gas-systems-produces-significant-fuel-savings/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
🏭
Hamworthy Moss (historic predecessor)
3 ✓ 3 verifiziert⚙️
MOSS 3000 / HM 3500
✓ verifiziert
verified_specs: {'Model Reference': 'HM 3500 IG (oxygen analyzer component)', 'Estimated Capacity Range': '3,000-3,500 Nm³/h', 'System Type': 'Burner/Scrubber with blower'}
application: Inert gas generation for tanker cargo tanks
model_source: https://www.shipparts.com/account/demand/detail/148331
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
4500 m³/h System
✓ verifiziert
verified_specs: {'Capacity': '4,500 Nm³/h', 'Documentation': 'Referenced in ShipParts inventory'}
application: Tanker inert gas generation
model_source: https://www.shipparts.com/account/demand/detail/153578
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
VLCC-series IGG (18,750 m³/h)
✓ verifiziert
verified_specs: {'Capacity': '18,750 Nm³/h (100% inert gas blower configuration)', 'Features': 'Deck water seals, P/V breakers', 'Application': 'VLCC tankers (316,000 DWT class)'}
application: Very Large Crude Carrier (VLCC) inert gas systems
model_source: https://www.rivieramm.com/news-content-hub/news-content-hub/moss-ig-systems-specified-for-vlcc-series-45398
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
🏭
Kvaerner / Hamworthy Moss (now Wärtsilä Moss)
2 ✓ 2 verifiziert⚙️
HM 3500 IG
✓ verifiziert
verified_specs: {'Nominal Capacity': '3500 m³/h', 'Oxygen Content': '1.0-5% by volume', 'Delivery Pressure': '~10.12 bar(g) at 100% capacity', 'Output Temperature': 'Up to 5°C above seawater temperature'}
application: Oil tanker inert gas generation system
model_source: https://www.shipparts.com/account/demand/detail/148331
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
MOSS Inert Gas System 4500
✓ verifiziert
verified_specs: {'Nominal Capacity': '4500 m³/h', 'System Type': 'Burner and scrubber combined unit, seawater-cooled', 'Oxygen Output': 'Less than 3% by volume', 'Fuel Type': 'Marine distillate (MGO/MDO) or HFO'}
application: Oil and product tanker cargo tank inerting
model_source: https://www.shipparts.com/account/demand/detail/153578
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
🏭
Smit
2 ✓ 2 verifiziert
Gas Master IG
✓ verifiziert
Inspector
7500 m3/h
· Inert Gas (flue gas)
· Inert Gas Generation
Common Failures:
- • Scrubber tower fouling
- • Deck seal water level low
- • O2 analyser drift
- • SO2 breakthrough
Service: Flue gas type; maintain scrubber water flow and deck seal water level.
Spares: Smit: Brennerdüsen-Satz, Photoauge und Dichtungen an Bord vorhalten. Lead time: 3-8 Wochen für Rohre.
Pros
- High-quality inert gas production
- Reliable and safe operation
- Compliance with IMO regulations
- Low maintenance requirements
- Compact design for efficient installation
Cons
- Scrubber tower fouling can occur if not properly maintained
- Requires regular monitoring of deck seal water level
- O2 analyser drift can affect system accuracy
- SO2 breakthrough can be a concern if not properly addressed
- Higher initial investment compared to some other models
Typical Vessels:
TankerLNG CarrierLPG Carrier
Certifications:
IMO D-2USCG Type Approval
Decision Guide: Choose if you require a reliable and safe inert gas generation system for tanker operations, with a focus on compliance with IMO regulations. Avoid if you are looking for a low-initial-investment solution or have limited space for installation.
Use Cases: Typically deployed on tankers, LNG carriers, and LPG carriers, where inert gas generation is crucial for safe cargo handling and transport.
⚙️
Inert Gas Master S
✓ verifiziert
Inspector
10000 m3/h
· Inert Gas (flue gas)
Common Failures:
- • Combustion chamber refractory damage
- • Scrubber nozzle blockage
- • Deck seal overflow
Service: Large VLCC size; refractory inspection every drydock.
Spares: Smit: Brennerdüsen-Satz, Photoauge und Dichtungen an Bord vorhalten. Lead time: 3-8 Wochen für Rohre.
🏭
Wärtsilä Moss
2 ✓ 2 verifiziert⚙️
IGG System (configurable, no discrete models)
✓ verifiziert
verified_specs: {'Maximum Capacity': '20,000 Nm³/h', 'Normal Discharge Pressure': '0.12 bar gauge', 'Fuel Consumption': '0.075 kg/Nm³ gas (nominal)', 'Seawater Consumption': '0.06 m³/Nm³ gas', 'Oxygen Content (adjustable)': 'Down to ~1%, typical 3%'}
application: Oil/Product tanker inert gas generation
model_source: https://www.wartsila.com/marine/products/gas-solutions/inert-gas/wartsila-moss-inert-gas-generators-for-tankers
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Mult-Inert™ System
✓ verifiziert
verified_specs: {'Capacity': 'Up to 20,000 Nm³/h', 'Operating Modes': 'IGG or Flue Gas system (switchable)', 'Discharge Pressure': '0.12 bar gauge', 'Design Feature': 'Compact modular configuration'}
application: Crude oil/refined product tanker (dual-mode operation)
model_source: https://www.wartsila.com/marine/products/gas-solutions/inert-gas/wartsila-moss-mult-inert-systems
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
🏭
Aalborg
1 ✓ 1 verifiziert⚙️
IGG 3000
✓ verifiziert
Inspector
5000 m3/h
· Inert Gas (flue gas)
Common Failures:
- • Scrubber packing deterioration
- • Non-return valve (deck) failure
- • Blower bearing wear
Service: Ensure O2 content <5% before admitting to cargo tanks; test P/V breakers.
Spares: Aalborg: Brennerdüsen-Satz, Photoauge und Dichtungen an Bord vorhalten. Lead time: 3-8 Wochen für Rohre.
🏭
Hamworthy Moss (Kvaerner-era product, now Wärtsilä)
1 ✓ 1 verifiziert⚙️
Moss Topping-Up Generator
✓ verifiziert
verified_specs: {'Capacity': '500 Nm³/h', 'Oxygen Content': 'Less than 3% by volume', 'Output Temperature': 'Up to 5°C above seawater temperature with 100% relative humidity', 'Fuel': 'Marine distillate, uses seawater for cooling'}
application: Tanker supplementary nitrogen generation
model_source: https://www.scribd.com/document/338485413/hamworthy-topping-up-generator-pdf
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
🏭
Kvaerner (E3 Tanker System Integration)
1 ✓ 1 verifiziert⚙️
E3 Tanker IGG System - Main + Topping-Up Generator
✓ verifiziert
verified_specs: {'Main Generator Capacity': '22,500 cu.m./h flue gas plant', 'Topping-Up Generator': '500 cu.m./h nitrogen generator', 'System Integration': 'Part of integrated liquid cargo handling system', 'Vessel Application': 'Large crude oil tanker with advanced automation'}
application: 280,000 DWT crude oil tanker integrated cargo system
model_source: https://www.marinelink.com/article/maritime-contracts/companies-spanning-contract-equipments-331
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
🏭
Kvaerner Ships Equipment (Moss product line)
1 ✓ 1 verifiziert⚙️
Moss Inert Gas Plant 7500
✓ verifiziert
verified_specs: {'Nominal Capacity': '7500 m³/h', 'System Configuration': 'Main generator unit with topping-up capacity', 'Oxygen Content': 'Less than 3% by volume (adjustable 1-5%)', 'Installation Type': 'Engine room mounted, compact modular design'}
application: Large tanker and FPSO inert gas generation
model_source: https://shipping-data.com/business/norway/lier/kvaerner-ships-equipment
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
🏭
Wärtsilä Moss (successor to Kvaerner/Hamworthy)
1 ✓ 1 verifiziert⚙️
Wärtsilä Moss Inert Gas Generator - Tanker Series
✓ verifiziert
verified_specs: {'Maximum Capacity': '20,000 Nm³/h', 'Normal Discharge Pressure': '0.12 bar(g)', 'Oxygen Content': 'Approximately 3% by volume', 'Fuel Consumption': '0.075 kg/Nm³ gas', 'Sea Water Consumption': '0.06 m³/Nm³ gas at 32°C', 'Design Features': 'Compact modular, containerized retrofit solutions, automated pressure regulation'}
application: Modern product and crude oil tanker inerting (retrofit & newbuild)
model_source: https://www.maritimeinformed.com/w-rtsil-moss-inert-gas-generators-for-tankers-inert-gas-systems-technical-details.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis