OS
← Compressors

Start Air Compressor

medium
High-pressure reciprocating compressors for main engine starting air (25-30 bar)

Known Models (9)

Atlas Copco LT Series
Atlas Copco LT Series
40-200 m³/h FAD @ 30-40 bar · 30.0 kW · Air
medium: Air
power_kw: 30
pressure_bar: 30
stages: 2
Common Failures:
  • • PTFE piston ring wear (oil-free)
  • • Intercooler moisture carryover
  • • Valve seat erosion
Service: Oil-free design — no oil contamination in air system. Higher ring wear rate vs. lubricated. Ring change every 4000 hrs.
Spares: Atlas Copco: Ventilsätze und Kolbenringe an Bord vorhalten. Lead time: 2-6 Wochen. Ölfilter und Dichtungssätze als Standard-Bordvorrat.
Hamworthy (Wärtsilä) 2TM4
Hamworthy (Wärtsilä) 2TM4
60 m³/h FAD @ 30 bar · 18.5 kW · Air
medium: Air
power_kw: 18.5
pressure_bar: 30
stages: 2
Common Failures:
  • • Valve plate fatigue
  • • Intercooler tube pitting
  • • Crosshead guide wear
  • • Oil scraper ring failure
Service: Robust design with long service life. Valve overhaul every 4000-6000 hrs. Spares now via Wärtsilä.
Spares: Hamworthy (Wärtsilä): Ventilsätze und Kolbenringe an Bord vorhalten. Lead time: 2-6 Wochen. Ölfilter und Dichtungssätze als Standard-Bordvorrat.
Hamworthy (Wärtsilä) 4TF6
Hamworthy (Wärtsilä) 4TF6
100 m³/h FAD @ 30 bar · 30.0 kW · Air
medium: Air
power_kw: 30
pressure_bar: 30
stages: 2
Common Failures:
  • • Valve failure
  • • Cooler tube corrosion
  • • Crankshaft bearing wear
  • • Safety valve lifting prematurely
Service: 4-cylinder design for high capacity. Monitor crankcase pressure. Spares via Wärtsilä aftermarket.
Spares: Hamworthy (Wärtsilä): Ventilsätze und Kolbenringe an Bord vorhalten. Lead time: 2-6 Wochen. Ölfilter und Dichtungssätze als Standard-Bordvorrat.
Sauer Compressors WP33L
Sauer Compressors WP33L
33 m³/h FAD @ 30 bar · 11.0 kW · Air
medium: Air
power_kw: 11
pressure_bar: 30
stages: 2
Common Failures:
  • • Valve disc fatigue
  • • Cylinder bore wear
  • • Aftercooler fin fouling
  • • Oil carry-over
Service: Air-cooled — ensure adequate ventilation. Valve overhaul every 4000 hrs. Oil change every 1000 hrs.
Spares: Sauer Compressors: Ventilsätze und Kolbenringe an Bord vorhalten. Lead time: 2-6 Wochen. Ölfilter und Dichtungssätze als Standard-Bordvorrat.
Sauer Compressors WP61L
Sauer Compressors WP61L
61 m³/h FAD @ 30 bar · 18.5 kW · Air
medium: Air
power_kw: 18.5
pressure_bar: 30
stages: 2
Common Failures:
  • • Suction valve failure
  • • Piston ring wear
  • • Oil separator element saturation
Service: Replace oil separator element every 2000 hrs. Valve service every 4000 hrs. Drain condensate.
Spares: Sauer Compressors: Ventilsätze und Kolbenringe an Bord vorhalten. Lead time: 2-6 Wochen. Ölfilter und Dichtungssätze als Standard-Bordvorrat.
Sauer Compressors WP85L
Sauer Compressors WP85L
85 m³/h FAD @ 30 bar · 27.0 kW · Air
medium: Air
power_kw: 27
pressure_bar: 30
stages: 2
Common Failures:
  • • Intercooler leakage
  • • High-stage piston ring failure
  • • Unloader solenoid stuck
Service: Water-cooled version for tropical operations. Valve OH every 4000 hrs. Monitor stage pressures.
Spares: Sauer Compressors: Ventilsätze und Kolbenringe an Bord vorhalten. Lead time: 2-6 Wochen. Ölfilter und Dichtungssätze als Standard-Bordvorrat.
Tanabe H-63
Tanabe H-63
63 m³/h FAD @ 30 bar · 18.5 kW · Air
medium: Air
power_kw: 18.5
pressure_bar: 30
stages: 2
Common Failures:
  • • Suction/delivery valve failure
  • • Piston ring wear
  • • Cooler tube leakage
  • • Unloader malfunction
Service: Very common on Japanese tonnage. Valve OH every 4000 hrs. Genuine Tanabe spares recommended.
Spares: Tanabe: Ventilsätze und Kolbenringe an Bord vorhalten. Lead time: 2-6 Wochen. Ölfilter und Dichtungssätze als Standard-Bordvorrat.
Tanabe H-64
Tanabe H-64
64 m³/h FAD @ 30 bar · 18.5 kW · Air
medium: Air
power_kw: 18.5
pressure_bar: 30
stages: 2
Common Failures:
  • • Valve plate cracking
  • • Intercooler fouling
  • • Piston ring blow-by
Service: Improved valve design over H-63. Same maintenance intervals: 4000 hrs valves, 8000 hrs rings.
Spares: Tanabe: Ventilsätze und Kolbenringe an Bord vorhalten. Lead time: 2-6 Wochen. Ölfilter und Dichtungssätze als Standard-Bordvorrat.
Tanabe VLH-22
Tanabe VLH-22
22 m³/h FAD @ 30 bar · 7.5 kW · Air
medium: Air
power_kw: 7.5
pressure_bar: 30
stages: 2
Common Failures:
  • • Valve failure
  • • V-belt slip
  • • Oil carry-over
Service: V-type compact design. Belt tension check every 1000 hrs. Valve service every 3000-4000 hrs.
Spares: Tanabe: Ventilsätze und Kolbenringe an Bord vorhalten. Lead time: 2-6 Wochen. Ölfilter und Dichtungssätze als Standard-Bordvorrat.