OS
← Inert Gas System

Nitrogen Generator

medium
Nitrogen generators for high-purity cargo tank inerting and purging

Known Models (2)

Alfa Laval Membrane N2 Generator
Alfa Laval Membrane N2 Generator
20-200 Nm³/h N2 @ 95-99% · Air → Nitrogen · Membrane N2 Generator
medium: Air → Nitrogen
type: Membrane N2 Generator
Common Failures:
  • • Membrane fiber degradation from oil/water
  • • Pre-filter failure
  • • Flow control valve malfunction
Service: Membrane N2 — lower purity than PSA but simpler. Oil-free air supply essential. Replace pre-filters regularly.
Spares: Alfa Laval: Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.
Parker (Domnick Hunter) MAXIGAS Marine N2
Parker (Domnick Hunter) MAXIGAS Marine N2
50-500 Nm³/h N2 · Air → Nitrogen · PSA Nitrogen Generator
medium: Air → Nitrogen
type: PSA Nitrogen Generator
Common Failures:
  • • Carbon molecular sieve degradation
  • • Switching valve failure
  • • O2 analyzer drift
  • • Air compressor fault
Service: PSA (Pressure Swing Adsorption). CMS replacement every 10-15 years. Monitor O2 purity continuously. Pre-filter maintenance critical.
Spares: Parker (Domnick Hunter): Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.