OS
← Emergency Equipment ER

Fire Detection ER

medium
Fire detection systems for engine room spaces

Known Models (2)

Autronica (Xtralis) AutroSafe Marine
Autronica (Xtralis) AutroSafe Marine
Ship-wide system · Emergency Equipment · Addressable Fire Detection
type: Addressable Fire Detection
Common Failures:
  • • Detector contamination from ER environment
  • • Loop communication error
  • • Sounder/beacon failure
  • • Panel software fault
Service: SOLAS fire detection. Clean detectors every 6 months (ER is dirty environment). Test detectors annually. Panel backup battery check.
Spares: Autronica (Xtralis): Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
Consilium Salwico Marine Fire Detection
Consilium Salwico Marine Fire Detection
Ship-wide system · Emergency Equipment · Conventional/Addressable Fire Detection
type: Conventional/Addressable Fire Detection
Common Failures:
  • • Detector head contamination
  • • Zone module failure
  • • Alarm bell corrosion
  • • Battery charger fault
Service: Widely installed on Scandinavian and Korean-built vessels. Annual detector function test. Battery replacement every 4 years.
Spares: Consilium: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.