OS
← Oil Mist Detection

Oil Mist Detector

medium
Crankcase oil mist detectors for main and auxiliary engine protection

Known Models (4)

Consilium Marine & Safety AB Short Circuit Isolator Detector Base UB-6 SCI, Short Circuit Isolator Base Adapter SPB-ADAPT SCI, Short Circuit Isolator NMI-SCI, Short Circuit Isolator Base Adapter CD-B SCI, Short Circuit Isolator Base Adapter IP-ADAPT SCI
Consilium Marine & Safety AB Short Circuit Isolator Detector Base UB-6 SCI, Short Circuit Isolator Base Adapter SPB-ADAPT SCI, Short Circuit Isolator NMI-SCI, Short Circuit Isolator Base Adapter CD-B SCI, Short Circuit Isolator Base Adapter IP-ADAPT SCI
Per engine crankcase monitoring · Oil Mist Detection
source: dnv-approval-finder
Common Failures:
  • • Sensor-Fenster Verschmutzung durch Ölnebel
  • • Referenz-Zelle Degradation
  • • Probenahmeleitung Verstopfung
  • • Alarm-Schwellwert Kalibrierungsdrift
Service: Sensor-Reinigung wöchentlich. Kalibrierung quartalsweise. Alarm-Test monatlich.
Spares: Ersatzteile über Consilium Marine & Safety AB oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
Daihatsu (Kidde) MD-SX OMD
Daihatsu (Kidde) MD-SX OMD
Per engine · Oil Mist Detection · Optical Oil Mist Detector
type: Optical Oil Mist Detector
Common Failures:
  • • Sensor contamination
  • • Sample extraction fan failure
  • • Alarm threshold drift
Service: Integrated with Daihatsu engine safety system. Weekly function test. Quarterly sensor cleaning.
Spares: Ersatzteile über Daihatsu (Kidde) oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
GEA Westfalia OMD System
GEA Westfalia OMD System
Per engine, multi-crankcase · Oil Mist Detection · Comparative Oil Mist Detector
type: Comparative Oil Mist Detector
Common Failures:
  • • Sample pipe leakage causing false readings
  • • Optics fouling
  • • Multiplexer valve failure
Service: Comparative type — detects relative increase in any one crankcase. Keep sample pipes clean and leak-free.
Spares: Ersatzteile über GEA Westfalia oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
Schaller Automation Visatron VN215+
Schaller Automation Visatron VN215+
Per engine, up to 20 crankcases · Oil Mist Detection · Optical Oil Mist Detector
type: Optical Oil Mist Detector
Common Failures:
  • • Sensor optics fouling
  • • Sample pipe blockage
  • • Reference cell degradation
  • • Relay output failure
Service: SOLAS mandatory for engines >2250 kW. Test weekly. Clean optics every 4000 hrs. Replace reference cell every 2 years.
Spares: Ersatzteile über Schaller Automation oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.