Electrolysis BWTS
medium
Ballast water treatment using electrochlorination/electrolysis
Known Models (6)
Ecochlor Ecochlor BWTS
variable
· Ballast Water Treatment
· chlorine_dioxide
type: chlorine_dioxide
imo_approved: True
Common Failures:
- • ClO2 generator failure
- • Chemical supply depletion
- • Neutralization imbalance
- • Dosing pump failure
Service: Chlorine dioxide chemical treatment. Chemical resupply required.
Spares: Ecochlor: UV-Lampen an Bord vorhalten (2 Sätze). Filterelemente: 1 Satz. Lead time: 2-4 Wochen.
JFE Engineering BallastAce BWTS
variable
· Ballast Water Treatment
· electrolysis
type: electrolysis
imo_approved: True
origin: Japan
Common Failures:
- • Electrode degradation
- • Electrolysis cell scaling
- • Control system failure
Service: Japanese manufacturer. Electrode life monitoring.
Spares: JFE Engineering: UV-Lampen an Bord vorhalten (2 Sätze). Filterelemente: 1 Satz. Lead time: 2-4 Wochen.
NK Company NK Balclor BWTS
variable
· Ballast Water Treatment
· electrolysis
type: electrolysis
imo_approved: True
origin: Korea
Common Failures:
- • Electrode erosion
- • TRO sensor drift
- • Power supply failure
- • Hydrogen gas ventilation issue
Service: Korean manufacturer. Monitor hydrogen generation during electrolysis.
Spares: NK Company: UV-Lampen an Bord vorhalten (2 Sätze). Filterelemente: 1 Satz. Lead time: 2-4 Wochen.
Panasonic (GS-YUASA) Panasonic Marine BWTS
variable
· Ballast Water Treatment
· electrolysis
type: electrolysis
origin: Japan
Common Failures:
- • Electrode failure
- • Control board malfunction
- • TRO measurement error
Service: Japanese electronics manufacturer entering marine. Electrode service.
Spares: Panasonic (GS-YUASA): UV-Lampen an Bord vorhalten (2 Sätze). Filterelemente: 1 Satz. Lead time: 2-4 Wochen.
Samsung Heavy Industries PureSeas BWTS
variable
· Ballast Water Treatment
· electrolysis
type: electrolysis
imo_approved: True
origin: Korea
Common Failures:
- • Electrode wear
- • TRO sensor failure
- • Power module malfunction
Service: Korean shipyard product. Electrode replacement schedule.
Spares: Samsung Heavy Industries: UV-Lampen an Bord vorhalten (2 Sätze). Filterelemente: 1 Satz. Lead time: 2-4 Wochen.
Techcross Techcross ECS BWTS
variable
· Ballast Water Treatment
· electrolysis
type: electrolysis
imo_approved: True
uscg_approved: True
origin: Korea
Common Failures:
- • Electrode erosion
- • TRO sensor calibration drift
- • Power supply failure
- • Neutralization system malfunction
Service: Korean manufacturer, largest BWTS market share. Electrode replacement per wear. TRO monitoring.
Spares: Techcross: UV-Lampen an Bord vorhalten (2 Sätze). Filterelemente: 1 Satz. Lead time: 2-4 Wochen.