Deluge/Sprinkler System
medium
64 Modelle gesamt
Known Models (64)
⚙️
Minimax Minifog EconAqua
verified_specs: {'Water Consumption': 'Up to 85% less than conventional sprinkler systems', 'Pump Room Size': 'Up to 80% smaller than classic sprinkler pump room', 'Nominal Pipe Diameter Range': 'DN20 to DN40', 'Maximum Ceiling Height': '3.6 meters (approved for multi-story and underground parking)', 'Certification': 'VdS-approved'}
application: Low-pressure water mist fire suppression for office buildings, hotels, underground parking facilities, multi-story buildings
model_source: https://www.minimax.com/int/en/technologies/minifog-water-mist-systems/minifog-econaqua/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Minimax Minifog ProCon
verified_specs: {'Water Consumption': 'Up to 70% less than conventional deluge systems', 'Operating Pressure': 'Approximately 9 bar (maintained by jockey pump)', 'Nozzle Type': 'ProCon fine spray nozzles', 'Configuration': 'Single-zone or multi-zone systems', 'Certification': 'VdS Schadenverhütung certified'}
application: Low-pressure water mist suppression for industrial facilities, enclosed and open areas, emergency power generators, machine tools
model_source: https://www.minimax.com/int/en/technologies/minifog-water-mist-systems/minifog-procon/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Minimax Minifog ProCon XP
verified_specs: {'Water Consumption': 'Approximately 95% less than conventional spray systems', 'Operating Pressure': '40 to 90 bar', 'Protected Volume': 'Up to 2,430 m³', 'Maximum Height': 'Up to 13.5 m', 'Coverage per Nozzle': 'Up to 21 m²', 'Technology': 'ConstantFlow technology', 'Certification': 'VdS Schadenverhütung and FM Global certified'}
application: High-pressure water mist suppression for emergency power generators, gas turbines, hydraulics rooms, machine tools, transformers
model_source: https://www.minimax.com/int/en/technologies/minifog-water-mist-systems/minifog-procon-xp/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Minimax Minifog Marine XP
verified_specs: {'Water Consumption': '90% less than conventional sprinkler systems', 'Coverage per Sprinkler': 'Up to 32 square meters in cabin applications', 'Engine Room Capacity': 'Suitable for up to 8,235 m³', 'Nozzle Material': 'Stainless steel (corrosion resistant)', 'Water Supply Options': 'Freshwater, filtered seawater, or shore connections (SOLAS compliant)', 'Certification': "IMO MSC.1/Circ. 1165 and Lloyd's Register certified"}
application: Maritime fire suppression for ship engine rooms and vessel compartments, methanol fire protection
model_source: https://www.minimax.com/int/en/technologies/minifog-water-mist-systems/minifog-marine-xp/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Minimax Deluge Systems (General)
verified_specs: {'Activation Methods': 'Hydraulic, pneumatic, or electric', 'Nozzle Models': 'Viking Model A and Model C-1 (UL-approved)', 'Valve Type': 'FSX Deluge Valve Set', 'Operating Pressure': '16 bar maximum permissible operating pressure', 'Water Consumption': 'Significantly below conventional deluge systems', 'Coverage Pattern': 'Entire protection zone with open nozzles'}
application: Emergency power generators, gas turbines, hydraulics rooms, machine tools, test stands, transformers, high-risk fire areas with flammable substances
model_source: https://www.minimax.com/int/en/technologies/water-suppression-systems/deluge-systems/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Minimax TraFoProtect (Transformer Protection System)
verified_specs: {'Nozzle Types': 'Type A (full-cone 90° or 120°) and Type C (fan-shaped 180°) optional for floor puddle fires', 'Fire Detection': 'UniVario flame/heat detectors with Buchholz relay integration', 'Control Panel': 'FMZ 5000 fire detection and extinguishing control', 'Water Supply Options': 'Direct service water network, existing sprinkler/hydrant systems, storage tank, or fire brigade backup', 'Water Consumption': 'Significantly below conventional deluge systems', 'Certification': 'UL Listed and DMT GmbH & Co. KG performance tested'}
application: Power transformer fire protection and cooling (oil-cooled transformers)
model_source: https://www.minimax.com/int/en/solutions/solutions-risks/trafoprotect/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Minimax PVProtect (Solar Panel Protection System)
verified_specs: {'Detection System': 'Linear heat differential detectors below photovoltaic modules', 'Localization': 'Heat differential detectors for precise fire source identification', 'Suppression': 'Specially designed nozzles at low operating pressures', 'Roof Inclination Limit': 'Up to 10 degrees', 'Water Supply': 'Integration with existing sprinkler system water supply (minimal pressure)', 'Notification': 'Automatic emergency services alert and building occupant warning', 'Certification': 'VdS Schadenverhütung approved'}
application: Fire protection for flat rooftops with photovoltaic (PV) solar panel installations
model_source: https://www.minimax.com/pvprotect
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Minimax MXOne (Firefighting Turbine)
verified_specs: {'Maximum Range (Water Mist)': '37 meters certified', 'Maximum Range (Full Jet)': '100 meters certified', 'Operating Temperature': '-15°C to +50°C', 'Rotation Capability': '360° coverage', 'Spray Modes': 'Full jet, water mist, or combination mode', 'Functionality': '4-in-1: extinguishing, cooling, smoke extraction, pollution binding', 'Control Options': 'Fully automatic or manual remote control', 'Installation Configurations': 'Stationary, tower-mounted, trailer-based, or flat-rack deployable', 'Certification': 'FM Global, MPA Dresden, DMT, FlameCert, bSafe tested'}
application: Airports, hangars, recycling facilities, industrial/logistics centers, energy infrastructure, chemical/petroleum industries, vehicle decks on ferries
model_source: https://www.minimax.com/int/en/technologies/water-suppression-systems/mxone/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Minimax Sprinkler Systems (Undercover)
verified_specs: {'Design Feature': 'Virtually flush with ceiling for aesthetic integration', 'Activation Type': 'Automatic temperature-actuated (selective activation)', 'System Types': 'Wet pipe, dry pipe, pilot-operated dry systems', 'Control Panel': 'ESS 5000 electronic control panel for electrically driven pumps', 'Coverage': 'Only sprinklers in immediate fire proximity activate (selective)'}
application: Office buildings, luxury hotel rooms, museums, showrooms, high-aesthetic indoor applications
model_source: https://www.minimax.com/int/en/technologies/water-suppression-systems/sprinkler-systems/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco DV-5A Automatic Water Control Valve
verified_specs: {'Sizes': '1-1/2 to 8 inch (DN40 to DN200)', 'Pressure Rating': '20-300 psi (1.4-20.7 bar)', 'Valve Type': 'Diaphragm style with external reset', 'Actuation Options': 'Wet, dry, or electric actuation'}
application: Deluge and Preaction Fire Protection Systems
model_source: https://www.tyco-fire.com/products-and-solutions/valves-devices-and-components/deluge-and-preaction-valves-and-components/dv-5a-d_fis/dv-5a-pretrim-deluge-valve
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco DV-5A Pre-trim Preaction Valve
verified_specs: {'Sizes': '1-1/2 to 8 inch (DN40 to DN200)', 'Pressure Rating': '20-300 psi (1.4-20.7 bar)', 'Configurations': 'Single Interlock (SI) and Double Interlock (DI) with electric/pneumatic combinations', 'Body Styles': 'Grooved x Grooved, Flange x Flange, Flange x Grooved, NPT'}
application: Single and Double Interlock Preaction Fire Protection Systems
model_source: https://www.tyco-fire.com/products-and-solutions/valves-devices-and-components/deluge-and-preaction-valves-and-components/dv-5a-p_fis/dv-5a-pretrim-preaction-valve
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco DV-5 Deluge Valve
verified_specs: {'Sizes': '1-1/2 to 8 inch (DN40 to DN200)', 'Pressure Rating': '250 psi (17.2 bar) standard', 'Design': 'External resetting diaphragm operation', 'Special Feature': 'Suitable for seawater and brackish water supplies'}
application: Standard Deluge and Preaction Fire Protection Systems (Legacy Model)
model_source: https://docs.johnsoncontrols.com/tycofire/v/u/Tyco/en-US/DV-5-Deluge-Valve-Diaphragm-Style-Datasheet
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco DPV-1 Preaction Type B Valve
verified_specs: {'Sizes': 'DN65, DN80, DN100, DN150 (available upon request)', 'Pressure Rating': '16 bar (VdS approval)', 'Design': 'Offset single clapper design with external reset', 'Installation': 'Vertical installation only (flow going up)', 'Material': 'Ductile iron body'}
application: Type B Single Interlock Preaction Fire Protection Systems
model_source: https://www.tyco-fire.com/products-and-solutions/valves-devices-and-components/deluge-and-preaction-valves-and-components/dpv1-p_fis/dpv-1-preaction-type-b-valve
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco Series MJC Multiple Jet Controls
verified_specs: {'Sizes': 'DN20, DN25, DN40, DN50', 'Pressure Rating': '1.4 to 12.0 bar', 'Actuation': 'Heat-actuated with frangible glass bulb; DN25/DN40/DN50 with optional thermoelectric', 'Installation Options': 'Upright or pendent', 'Approvals': 'LPCB Approved (Europe only)'}
application: Auxiliary Deluge Control Valves for Zone Protection
model_source: https://www.tyco-fire.com/products-and-solutions/valves-devices-and-components/deluge-and-preaction-valves-and-components/mjc_fis/mjc-multiple-jet-controls
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco DV-5A Deluge Red-E Cabinet
verified_specs: {'Components': 'Integrated DV-5A valve, manual shut-off, flow/supervisory switches, air compressor', 'Cabinet Material': '14-gauge steel construction', 'Features': 'Forklift compatible, removable hinged doors, minimal floor space', 'Certifications': 'UL, C-UL, CSFM Listed'}
application: Pre-assembled Integrated Deluge Fire Protection Package
model_source: https://www.tyco-fire.com/products-and-solutions/valves-devices-and-components/deluge-and-preaction-valves-and-components/red-e-d_fis/dv-5a-deluge-red-e-cabinet
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco DV-5A Preaction Red-E Cabinet
verified_specs: {'Components': 'Integrated DV-5A preaction valve with release trim', 'Cabinet Material': '14-gauge steel', 'Integrated Systems': 'Manual controls, compressor, pressure gauges', 'Certifications': 'UL, C-UL, FM, LPCB'}
application: Pre-assembled Integrated Preaction Fire Protection Package
model_source: https://www.tyco-fire.com/products-and-solutions/valves-devices-and-components/deluge-and-preaction-valves-and-components/red-e-p_fis/dv-5a-preaction-red-e-cabinet
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco Duct Deluge System (DDS)
verified_specs: {'Main Component': 'Type DN-5 Corrosion Resistant Duct Nozzle', 'Corrosion Protection': 'HALAR (ECTFE) coating for extreme acid resistance', 'Ductwork Compatibility': 'FRP, PVC, or PP ductwork (circular, rectangular, or irregular)', 'System Components': 'DN-5 nozzle, Red-E Cabinet, Protectowire linear heat detection, FlexHead mounting', 'Temperature Range': 'Up to 150°C (302°F)', 'Coverage': 'Ducts 1 to 16 ft width'}
application: Protection of Ventilation Ductwork Handling Extremely Corrosive Gases
model_source: https://www.tyco-fire.com/products-and-solutions/sprinklers-nozzles-and-accessories/nozzles/dds_fis/duct-deluge-system
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco Type DN-5 Corrosion Resistant Duct Nozzle
verified_specs: {'Type': 'Open non-automatic directional spray nozzle', 'Material': 'Stainless steel with HALAR coating', 'Corrosive Resistance': 'HCl, HF, H2SO4, HNO3, SO2 resistant', 'Discharge Pattern': 'Medium velocity uniform water spray cone', 'Design Specification': 'FM Data Sheet 7-78 compliant'}
application: Deluge Nozzle for Corrosive Gas Ventilation Ductwork Protection
model_source: https://docs.johnsoncontrols.com/tycofire/v/u/Tyco/en-US/Type-DN-5-Corrosion-Resistant-Duct-Nozzle-Open-Medium-Velocity/08-2025
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco Type D3 Protectospray Directional Spray Nozzles
verified_specs: {'Type': 'Open non-automatic directional spray nozzles', 'Pressure Rating': '175 psi (12.1 bar) maximum', 'Thread Size': '1/2 inch NPT (DN15)', 'K-Factors Available': '1.2 to 7.2 GPM/psi^0.5', 'Orifice Range': '0.203 to 0.500 inches', 'Discharge Pattern': 'Uniformly filled cone of medium-velocity droplets'}
application: Water-Spray-Fixed Deluge Systems for Equipment and Structural Protection
model_source: https://www.tyco-fire.com/products-and-solutions/sprinklers-nozzles-and-accessories/nozzles/d3n_fis/type-d3-protectospray-nozzles
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco TN-17 Horizontal Spray Nozzle
verified_specs: {'K-Factor': '16.8 (K240)', 'Orientation': 'Horizontal', 'Thread Size': '3/4 inch NPT', 'Coverage': 'Up to 16 ft 4 in. x 32 ft 8 in. (5.0 m x 10.0 m)', 'Pressure Range': '10-30 psi (0.7-2.1 bar)', 'Special Feature': 'Single pipe covers ~65 ft tunnel width'}
application: Tunnel Fire Protection Deluge Systems
model_source: https://www.tyco-fire.com/products-and-solutions/sprinklers-nozzles-and-accessories/nozzles/tn-17_fis/tn-17-horizontal-spray-nozzle
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco TN-25 Horizontal Spray Nozzle
verified_specs: {'K-Factor': '25.2 (K360)', 'Orientation': 'Horizontal', 'Thread Size': '1 inch', 'Coverage': 'Up to 16 ft 4 in. x 24 ft 7 in.', 'Discharge': 'Greater stream diameter and lower pressure for larger droplets', 'Certifications': 'UL and C-UL Listed'}
application: Tunnel Fire Protection Deluge Systems
model_source: https://www.tyco-fire.com/products-and-solutions/sprinklers-nozzles-and-accessories/nozzles/tn-25_fis/tn-25-horizontal-spray-nozzle
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco Model B-1 Foam-Water Sprinklers
verified_specs: {'K-Factor': '3.0 GPM/psi (43.2 LPM/bar)', 'Design': 'Air-aspirating venturi-style body', 'Thread Size': '1/2 inch NPT', 'Orientation': 'Upright or pendent', 'Pressure Rating': '175 psi (12.1 bar) maximum', 'Standards': 'NFPA 16 compliant'}
application: Foam-Water Deluge Systems for Flammable Liquid Protection
model_source: https://www.tyco-fire.com/products-and-solutions/sprinklers-nozzles-and-accessories/nozzles/b-1_fis/model-b-1-foam-water-sprinklers
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco Solenoid Valve
verified_specs: {'Pressure Ratings': '175 psi (12.1 bar) and 300 psi (20.7 bar) models', 'Function': 'Energized by releasing panel to trigger automatic water control valve', 'System Type': 'Works with deluge and preaction systems', 'Approvals': 'FM Approved models available', 'Specifications': 'Multiple voltage options, hazardous location certified variants'}
application: Electric Actuation of Deluge and Preaction Fire Protection Valves
model_source: https://www.tyco-fire.com/products-and-solutions/valves-devices-and-components/deluge-and-preaction-valves-and-components/solenoid_fis/solenoid-valve
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco DP-1 Dry Pilot Actuator
verified_specs: {'Water Pressure': '250 psi (17.2 bar) maximum', 'Air/Nitrogen Pressure': '50 psi (3.4 bar) maximum', 'Material': 'Bronze body and cover', 'Function': 'Releases air pressure to actuate water control valves', 'Certifications': 'UL, C-UL, FM, LPCB approved'}
application: Pneumatic Actuation for Deluge and Preaction Systems
model_source: https://www.tyco-fire.com/products-and-solutions/valves-devices-and-components/deluge-and-preaction-valves-and-components/dp-1_fis/dp-1-dry-pilot-actuator
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco DP-2 Dry Pilot Actuator
verified_specs: {'Function': 'Pneumatic release device for deluge/preaction valves', 'Pressure Range': 'Suitable for moderate to high pressure systems', 'Design': 'Enhanced version of DP-1 for specific applications'}
application: Advanced Pneumatic Actuation for Deluge and Preaction Systems
model_source: https://www.tyco-fire.com/products-and-solutions/valves-devices-and-components/deluge-and-preaction-valves-and-components/dp-2_fis/dp-2-dry-pilot-actuator
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco MRA-1 Manual Reset Actuator
verified_specs: {'Pressure Rating': '300 psi (20.7 bar)', 'Material': 'Bronze body construction', 'Mechanism': 'Hydraulic latch maintains tripped position', 'Feature': 'External reset restores valve after system shutdown', 'Actuation': 'Triggered via solenoid valve, DP-1, or MC-1 control station'}
application: Manual Reset Mechanism for DV-5A Deluge/Preaction Valves
model_source: https://www.tyco-fire.com/products-and-solutions/valves-devices-and-components/deluge-and-preaction-valves-and-components/mra-1_fis/mra-1-manual-reset-actuator
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco FTR-1 Fixed Temperature Release
verified_specs: {'Type': 'Fixed temperature heat detector with glass bulb', 'Temperature Options': 'Ordinary and intermediate temperature ratings available', 'Pressure Rating': '250 psi (17.2 bar)', 'Thread Size': '1/2 inch NPT', 'Service': 'Wet or dry pilot release', 'Maximum Spacing': '40x40 feet or 30x30 feet (depending on model)'}
application: Heat Detection for Deluge and Preaction System Actuation
model_source: https://www.tyco-fire.com/products-and-solutions/valves-devices-and-components/deluge-and-preaction-valves-and-components/ftr-1_fis/ftr-1-fixed-temperature-release
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Tyco MC-1 Manual Control Station
verified_specs: {'Pressure Range': '20-300 psi (1.4-20.7 bar)', 'Design': 'Tamper-resistant with break rod mechanism', 'Connection': 'Direct wet pilot or indirect pneumatic (via DP-1)', 'Temperature Requirements': 'Dry pilot: -50°F (-46°C) min; Wet pilot: 40°F (4°C) min', 'Material': 'Thermoplastic box with Teflon elastomer seal', 'Certifications': 'UL, C-UL Listed, FM Approved'}
application: Manual Emergency Release for Deluge and Preaction Systems
model_source: https://www.tyco-fire.com/products-and-solutions/valves-devices-and-components/deluge-and-preaction-valves-and-components/mc-1_fis/mc-1-manual-control-station
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Minimax Marine MX Deluge
marine_approved: True
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:58:47
⚙️
Minimax Marine MX Sprinkler
marine_approved: True
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:58:47
⚙️
Minimax Marine Minimax Marine Sprinkler Accommodation-B
application: Accommodation
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
Minimax Marine Minimax Marine Sprinkler Machinery-B
application: Machinery
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
Minimax Marine Minimax Marine Sprinkler Car Deck-B
application: Car Deck
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
Minimax Marine Minimax Marine Sprinkler Helideck-B
application: Helideck
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
Minimax Marine Minimax Marine Sprinkler RoRo Space-B
application: RoRo Space
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
Minimax Marine Minimax Marine Sprinkler Storage-B
application: Storage
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
NAFFCO Marine NAFFCO Deluge Marine
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:58:47
⚙️
NAFFCO Marine NAFFCO Sprinkler Marine
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:58:47
⚙️
NAFFCO Marine NAFFCO Pre-Action Marine
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:58:47
⚙️
NAFFCO Marine NAFFCO Marine Sprinkler Accommodation-B
application: Accommodation
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
NAFFCO Marine NAFFCO Marine Sprinkler Machinery-B
application: Machinery
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
NAFFCO Marine NAFFCO Marine Sprinkler Car Deck-B
application: Car Deck
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
NAFFCO Marine NAFFCO Marine Sprinkler Helideck-B
application: Helideck
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
NAFFCO Marine NAFFCO Marine Sprinkler RoRo Space-B
application: RoRo Space
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
NAFFCO Marine NAFFCO Marine Sprinkler Storage-B
application: Storage
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
Tyco / Johnson Controls Deluge DV-5
imo_compliant: True
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:58:47
⚙️
Tyco / Johnson Controls Deluge DV-5S
imo_compliant: True
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:58:47
⚙️
Tyco / Johnson Controls Sprinkler SW-12
imo_compliant: True
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:58:47
⚙️
Tyco / Johnson Controls Sprinkler SW-20
imo_compliant: True
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:58:47
⚙️
Tyco / Johnson Controls Tyco Sprinkler Accommodation-B
application: Accommodation
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
Tyco / Johnson Controls Tyco Sprinkler Machinery-B
application: Machinery
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
Tyco / Johnson Controls Tyco Sprinkler Car Deck-B
application: Car Deck
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
Tyco / Johnson Controls Tyco Sprinkler Helideck-B
application: Helideck
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
Tyco / Johnson Controls Tyco Sprinkler RoRo Space-B
application: RoRo Space
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
Tyco / Johnson Controls Tyco Sprinkler Storage-B
application: Storage
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
Viking Group (Fire) VK Marine Sprinkler
marine_approved: True
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:58:47
⚙️
Viking Group (Fire) VK Marine Deluge
marine_approved: True
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:58:47
⚙️
Viking Group (Fire) VK Marine Pre-Action
marine_approved: True
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:58:47
⚙️
Viking Group (Fire) Viking Group (Fire) Sprinkler Accommodation-B
application: Accommodation
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
Viking Group (Fire) Viking Group (Fire) Sprinkler Machinery-B
application: Machinery
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
Viking Group (Fire) Viking Group (Fire) Sprinkler Car Deck-B
application: Car Deck
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
Viking Group (Fire) Viking Group (Fire) Sprinkler Helideck-B
application: Helideck
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
Viking Group (Fire) Viking Group (Fire) Sprinkler RoRo Space-B
application: RoRo Space
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37
⚙️
Viking Group (Fire) Viking Group (Fire) Sprinkler Storage-B
application: Storage
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-23T00:04:37