SCBA (Self-Contained Breathing Apparatus)
critical
IMO Required
9 Modelle gesamt
SCBA for fire-fighting and rescue per SOLAS II-2/10.10.
8760h
Service Interval
Typical Manufacturers
Dräger
MSA
Interspiro
3 Hersteller · 9 Modelle
🏭
Dräger
5 ✓ 5 verifiziert⚙️
Dräger PSS 5000 SCBA
✓ verifiziert
Inspector
6.8 L / 300 bar cylinder, 30 min rated
· Fire Suppression / Detection
Common Failures:
- • Face mask seal deterioration
- • Demand valve diaphragm failure
- • Cylinder valve O-ring leak
Service: Annual service per EN 137. Cylinder hydrostatic test every 5 years. Face mask fit test for each user.
Spares: Dräger: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.
⚙️
Dräger PSS 3000
✓ verifiziert
equipment_type: scba
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.85
solas_type: SOLAS/EN 137
series: PSS
model_code: PSS 3000
SCBA — entry level SCBA
⚙️
Dräger PSS 5000
✓ verifiziert
equipment_type: scba
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.85
solas_type: SOLAS/EN 137
series: PSS
model_code: PSS 5000
SCBA — professional SCBA
⚙️
Dräger PSS 7000
✓ verifiziert
equipment_type: scba
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.85
solas_type: SOLAS/EN 137
series: PSS
model_code: PSS 7000
SCBA — premium SCBA
⚙️
Dräger PSS AirBoss
✓ verifiziert
equipment_type: scba
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.85
solas_type: SOLAS/EN 137
series: PSS
model_code: PSS AirBoss
SCBA — high-performance SCBA
🏭
MSA
3 ✓ 3 verifiziert⚙️
MSA AirMaXX SCBA
✓ verifiziert
Inspector
6.8 L / 300 bar, 30 min rated
· Fire Suppression / Detection
Common Failures:
- • Lung demand valve free-flow
- • Harness buckle breakage
- • Low-pressure alarm whistle blockage
Service: Function test before each use. Annual overhaul per MSA service schedule. Cylinder test per national regulations.
Spares: MSA: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.
⚙️
MSA AirGo
✓ verifiziert
equipment_type: scba
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.8
solas_type: EN 137
model_code: AirGo
SCBA — basic SCBA
⚙️
MSA AirMaXX
✓ verifiziert
equipment_type: scba
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.8
solas_type: EN 137
model_code: AirMaXX
SCBA — premium SCBA
🏭
Interspiro
1 ✓ 1 verifiziert⚙️
Interspiro Spiromatic S8 SCBA
✓ verifiziert
Inspector
6.9 L / 300 bar, 30 min rated
· Fire Suppression / Detection
Common Failures:
- • Positive pressure regulator drift
- • Quick-connect coupling leak
- • HUD (heads-up display) battery failure
Service: HUD battery replacement annually. Full service per Interspiro maintenance manual.
Spares: Interspiro: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.