Wird verarbeitet…
OSM

EEBD (Emergency Escape Breathing Device)

critical IMO Required 2 / 2 Modelle (Inspector)
Emergency escape breathing device providing minimum 15 min air supply per SOLAS II-2/13.3.4.
8760h
Service Interval

Typical Manufacturers

Dräger MSA
Inspector Mode Show All 2 / 2 with inspector value

2 Hersteller · 2 Modelle

🏭

Dräger

1 ✓ 1 verifiziert
⚙️
Dräger Saver CF15 EEBD ✓ verifiziert Inspector
15 min rated duration, compressed air · Marine Equipment
Common Failures:
  • • Cylinder pressure drop over time
  • • Hood anti-fog coating deterioration
  • • Activation handle corrosion
Service: Monthly pressure gauge check. Service every 5 years or per manufacturer schedule. Replace after single use.
Spares: Dräger: Sicherheitsausrüstung per SOLAS-Mindestbestand. Lead time: 2-4 Wochen.
🏭

MSA

1 ✓ 1 verifiziert
⚙️
MSA S-CAP EEBD ✓ verifiziert
15 min rated, chemical oxygen · Marine Equipment
Common Failures:
  • • KO₂ canister moisture ingress
  • • Hood neck seal ageing
  • • Carrying case latch failure
Service: Annual inspection per MSA maintenance manual. Replace canister at expiry. Store in dry location.
Spares: MSA: Sicherheitsausrüstung per SOLAS-Mindestbestand. Lead time: 2-4 Wochen.