Marine fire and smoke dampers for ventilation system fire safety
4 Hersteller · 7 Modelle
🏭
Kongsberg
4 ✓ 4 verifiziert⚙️
Kongsberg Bronswerk FD-200
✓ verifiziert
application: marine ventilation / fire safety
damper_type: fire damper
size_mm: 200
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T14:21:18.789816+00:00
confidence: high
⚙️
Kongsberg Bronswerk FD-400
✓ verifiziert
application: marine ventilation / fire safety
damper_type: fire damper
size_mm: 400
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T14:21:18.789816+00:00
confidence: high
⚙️
Kongsberg Bronswerk FD-600
✓ verifiziert
application: marine ventilation / fire safety
damper_type: fire damper
size_mm: 600
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T14:21:18.789816+00:00
confidence: high
⚙️
Kongsberg Bronswerk FD-800
✓ verifiziert
application: marine ventilation / fire safety
damper_type: fire damper
size_mm: 800
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T14:21:18.789816+00:00
confidence: high
🏭
Barclay
1 ✓ 1 verifiziert⚙️
Marine Fire Damper A-60
✓ verifiziert
PREMIUM
Various duct sizes
· Conditioned Air / Exhaust Air
· Fire Damper A-60
type: Fire Damper A-60
Common Failures:
- • Fusible link corrosion
- • Blade binding from paint/corrosion
- • Actuator failure
- • Indication switch fault
Service: SOLAS A-60 fire integrity. Test closure monthly. Replace fusible links every 5 years. PSC inspection focus item.
Spares: Barclay: Lüftermotor-Lager und Keilriemen an Bord vorhalten. Lead time: 2-4 Wochen.
🏭
Ginge-Kerr
1 ✓ 1 verifiziert⚙️
Marine Fire/Smoke Damper
✓ verifiziert
PREMIUM
Various duct sizes
· Conditioned Air / Exhaust Air
· Fire/Smoke Damper A-60
type: Fire/Smoke Damper A-60
Common Failures:
- • Blade corrosion
- • Fusible link aging
- • Motor actuator failure
- • Microswich failure
Service: Ginge-Kerr established marine brand. Monthly operation test. Annual full inspection per class requirements.
Spares: Ginge-Kerr: Lüftermotor-Lager und Keilriemen an Bord vorhalten. Lead time: 2-4 Wochen.
🏭
Novenco Marine & Offshore
1 ✓ 1 verifiziert
Marine Fire/Smoke Damper
✓ verifiziert
PREMIUM
Various duct sizes
· Conditioned Air / Exhaust Air
· Fire/Smoke Damper A-60
type: Fire/Smoke Damper A-60
Common Failures:
- • Actuator spring failure
- • Blade seal degradation
- • Position indicator fault
- • Control circuit wire damage
Service: Dual-purpose fire/smoke damper. Monthly test per SOLAS. Annual full-stroke test with fire alarm integration.
Spares: Novenco Marine & Offshore: Lüftermotor-Lager und Keilriemen an Bord vorhalten. Lead time: 2-4 Wochen.