OS
← Inert Gas System

Flue Gas IG System

medium
Inert gas generators using boiler flue gas for cargo tank inerting

Known Models (2)

Alfa Laval (Smit) Smit Gas Inert Gas System
Alfa Laval (Smit) Smit Gas Inert Gas System
3000-15000 m³/h IG · Flue Gas → Inert Gas · Flue Gas IG System
medium: Flue Gas → Inert Gas
type: Flue Gas IG System
Common Failures:
  • • Scrubber nozzle erosion
  • • Deck seal water level loss
  • • Blower bearing failure
  • • O2 analyzer calibration drift
Service: SOLAS/MARPOL mandatory on tankers. O2 content <5% (target <3%). Test non-return valves monthly. Annual scrubber inspection.
Spares: Alfa Laval (Smit): Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.
Wärtsilä (Hamworthy) Marine IG System
Wärtsilä (Hamworthy) Marine IG System
5000-25000 m³/h IG · Flue Gas → Inert Gas · Flue Gas IG System
medium: Flue Gas → Inert Gas
type: Flue Gas IG System
Common Failures:
  • • Scrubber packing degradation
  • • IG blower motor failure
  • • Deck water seal level alarm
  • • Gas regulating valve malfunction
Service: Hamworthy IG systems widely installed. Monthly non-return valve test. Annual scrubber internal inspection.