Wird verarbeitet…
OSM

Flue Gas IG System

medium 2 / 2 Modelle (Inspector)
Inert gas generators using boiler flue gas for cargo tank inerting
Inspector Mode Show All 2 / 2 with inspector value

2 Hersteller · 2 Modelle

🏭

Alfa Laval

1 ✓ 1 verifiziert
Alfa Laval (Smit) Smit Gas Inert Gas System
Smit Gas Inert Gas System ✓ verifiziert PREMIUM
3000-15000 m³/h IG · Flue Gas → Inert Gas · Flue Gas IG System
medium: Flue Gas → Inert Gas
type: Flue Gas IG System
Common Failures:
  • • Scrubber nozzle erosion
  • • Deck seal water level loss
  • • Blower bearing failure
  • • O2 analyzer calibration drift
Service: SOLAS/MARPOL mandatory on tankers. O2 content <5% (target <3%). Test non-return valves monthly. Annual scrubber inspection.
Spares: Alfa Laval (Smit): Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.
🏭

Wärtsilä

1 ✓ 1 verifiziert
⚙️
Marine IG System ✓ verifiziert PREMIUM
5000-25000 m³/h IG · Flue Gas → Inert Gas · Flue Gas IG System
medium: Flue Gas → Inert Gas
type: Flue Gas IG System
Common Failures:
  • • Scrubber packing degradation
  • • IG blower motor failure
  • • Deck water seal level alarm
  • • Gas regulating valve malfunction
Service: Hamworthy IG systems widely installed. Monthly non-return valve test. Annual scrubber internal inspection.
Spares: Wärtsilä (Hamworthy): Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.