Wird verarbeitet…
OSM

Water Mist System

medium 9 / 9 Modelle (Inspector)
High-pressure water mist fire suppression (HI-FOG and similar)
Inspector Mode Show All 9 / 9 with inspector value

3 Hersteller · 9 Modelle

🏭

Marioff

4 ✓ 4 verifiziert
⚙️
Marioff HI-FOG CPU2020 Fixed System ✓ verifiziert
equipment_type: water_mist_fixed
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.8
series: HI-FOG
model_code: CPU2020
HI-FOG fixed fire suppression — medium capacity
⚙️
Marioff HI-FOG CPU2030 Fixed System ✓ verifiziert
equipment_type: water_mist_fixed
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.8
series: HI-FOG
model_code: CPU2030
HI-FOG fixed fire suppression — high capacity
⚙️
Marioff HI-FOG Micro Fixed System ✓ verifiziert
equipment_type: water_mist_fixed
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.8
series: HI-FOG
model_code: Micro
HI-FOG fixed fire suppression — compact
⚙️
Marioff HI-FOG Minifog XP Fixed System ✓ verifiziert
equipment_type: water_mist_fixed
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.8
series: HI-FOG
model_code: Minifog XP
HI-FOG fixed fire suppression — local application
🏭

Marioff (Carrier)

4 ✓ 4 verifiziert
⚙️
HI-FOG Cargo ✓ verifiziert Inspector
cargo hold protection · Fire Suppression / Detection
agent: water_mist
pressure_bar: 140
solas: True
spaces: ['cargo']
Common Failures:
  • • High-pressure pump failure
  • • Nozzle blockage from water quality
  • • Accumulator pre-charge loss
  • • Control valve stiction
Service: Water quality critical — use demineralized water. Annual pump test. Nozzle inspection every 5 years.
Spares: Marioff (Carrier): Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.
⚙️
HI-FOG Engine Room ✓ verifiziert Inspector
engine room · Fire Suppression / Detection
agent: water_mist
pressure_bar: 140
solas: True
spaces: ['engine_room']
Common Failures:
  • • HP pump seal failure
  • • Nozzle blockage
  • • Section valve malfunction
  • • Water tank contamination
Service: Replaces CO2 in many modern vessels. Annual pump and nozzle test.
Spares: Marioff (Carrier): Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.
⚙️
HI-FOG Accommodation ✓ verifiziert Inspector
accommodation · Fire Suppression / Detection
agent: water_mist
pressure_bar: 140
solas: True
spaces: ['accommodation']
Common Failures:
  • • Nozzle blockage from hard water
  • • Pump motor failure
  • • Section valve leak
Service: Common on cruise ships. Water quality monitoring essential.
Spares: Marioff (Carrier): Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.
⚙️
HI-FOG Turbo ✓ verifiziert Inspector
turbocharger enclosure · Fire Suppression / Detection
agent: water_mist
pressure_bar: 140
solas: True
spaces: ['turbocharger']
Common Failures:
  • • HP nozzle clogging
  • • Accumulator bladder failure
  • • Detection sensor contamination
Service: Local application for TC casing protection. Annual test.
Spares: Marioff (Carrier): Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.
🏭

Danfoss (Semco)

1 ✓ 1 verifiziert
⚙️
Semco S-type Water Mist ✓ verifiziert Inspector
variable · Fire Suppression / Detection
agent: water_mist
solas: True
Common Failures:
  • • Pump pressure fluctuation
  • • Nozzle orifice blockage
  • • Section valve failure
Service: Danish manufacturer. Competitor to HI-FOG.
Spares: Danfoss (Semco): Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.