Gas Detection (Cargo Area)
medium
6 Modelle gesamt
Fixed gas detection for gas carrier cargo areas
4 Hersteller · 6 Modelle
🏭
Dräger
3 ✓ 3 verifiziert
Polytron IR Gas Carrier
✓ verifiziert
Inspector
point detection
· LNG / LPG / Gas Cargo
· fixed
type: fixed
sensor: IR
application: gas_carrier
Common Failures:
- • IR window contamination
- • Electronics failure
- • Heated sensor malfunction
Service: IR sensor — no sensor poisoning. Window cleaning annually.
Spares: Dräger: Ersatzteile per Hersteller. Lead time: 3-8 Wochen. Dichtungen und Ventileinsätze an Bord vorhalten.
⚙️
Dräger PIR 7000 IR Gas Detector
✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.7
instrument_type: gas_detection_cargo
Point infrared gas detector for cargo areas
⚙️
Dräger Polytron 8700 Toxic Gas Detector
✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.7
instrument_type: gas_detection_cargo
Fixed toxic gas detector (H2S, NH3)
🏭
MSA
1 ✓ 1 verifiziert⚙️
Ultima Marine Gas Carrier
✓ verifiziert
Inspector
point detection
· LNG / LPG / Gas Cargo
· fixed
type: fixed
application: gas_carrier
Common Failures:
- • Sensor poisoning
- • Calibration drift
- • 4-20mA signal fault
- • Housing corrosion
Service: IR or catalytic sensor. Calibrate every 3 months for cargo spaces.
Spares: MSA: Ersatzteile per Hersteller. Lead time: 3-8 Wochen. Dichtungen und Ventileinsätze an Bord vorhalten.
🏭
Oldham
1 ✓ 1 verifiziert⚙️
Oldham OLCT 200 Fixed Gas Detector
✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.7
instrument_type: gas_detection_cargo
Fixed gas detection for cargo pump rooms
🏭
Simtronics
1 ✓ 1 verifiziert⚙️
MultiSafe Gas Carrier
✓ verifiziert
Inspector
multi-point
· LNG / LPG / Gas Cargo
· multi_point
type: multi_point
application: gas_carrier
Common Failures:
- • Sample line blockage
- • Pump failure
- • Sensor degradation
- • Condensation in sample lines
Service: Multi-point sampling system. Sample line purge regularly.
Spares: Simtronics: Ersatzteile per Hersteller. Lead time: 3-8 Wochen. Dichtungen und Ventileinsätze an Bord vorhalten.