Wird verarbeitet…
OSM

Generator Set

critical 46 / 46 Modelle (Inspector)
Inspector Mode Show All 46 / 46 with inspector value

8 Hersteller · 46 Modelle

🏭

ABB

11 ✓ 11 verifiziert
⚙️
ABB AMG 0450 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: AMG
power_kva: 450
⚙️
ABB AMG 0550 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: AMG
power_kva: 550
⚙️
ABB AMG 0630 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: AMG
power_kva: 630
⚙️
ABB AMG 0710 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: AMG
power_kva: 710
⚙️
ABB AMG 0800 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: AMG
power_kva: 800
⚙️
ABB AMG 0900 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: AMG
power_kva: 900
⚙️
ABB AMG 1000 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: AMG
power_kva: 1000
⚙️
ABB AMG 1120 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: AMG
power_kva: 1120
⚙️
ABB AMG 1250 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: AMG
power_kva: 1250
⚙️
ABB AMG 1400 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: AMG
power_kva: 1400
⚙️
ABB AMG 1600 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: AMG
power_kva: 1600
🏭

Siemens

11 ✓ 11 verifiziert
⚙️
Siemens SIGENTICS 1FC2 281 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: 1FC2
power_kva: 280
⚙️
Siemens SIGENTICS 1FC2 311 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: 1FC2
power_kva: 310
⚙️
Siemens SIGENTICS 1FC2 351 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: 1FC2
power_kva: 350
⚙️
Siemens SIGENTICS 1FC2 401 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: 1FC2
power_kva: 400
⚙️
Siemens SIGENTICS 1FC2 451 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: 1FC2
power_kva: 500
⚙️
Siemens SIGENTICS 1FJ4 282 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: 1FJ4
power_kva: 280
⚙️
Siemens SIGENTICS 1FJ4 352 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: 1FJ4
power_kva: 350
⚙️
Siemens SIGENTICS 1FJ4 402 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: 1FJ4
power_kva: 450
⚙️
Siemens SIGENTICS 1FJ4 452 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: 1FJ4
power_kva: 500
⚙️
Siemens SIGENTICS 1FJ4 502 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: 1FJ4
power_kva: 600
⚙️
Siemens SIGENTICS 1FJ4 562 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: 1FJ4
power_kva: 700
🏭

Nishishiba

8 ✓ 8 verifiziert
⚙️
Nishishiba NTA-400 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.8
series: NTA
power_kva: 400
⚙️
Nishishiba NTA-550 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.8
series: NTA
power_kva: 550
⚙️
Nishishiba NTA-750 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.8
series: NTA
power_kva: 750
⚙️
Nishishiba NTAK-400 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.8
series: NTAK
power_kva: 400
⚙️
Nishishiba NTAK-550 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.8
series: NTAK
power_kva: 550
⚙️
Nishishiba NTAK-750 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.8
series: NTAK
power_kva: 750
⚙️
Nishishiba NTAK-1000 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.8
series: NTAK
power_kva: 1000
⚙️
Nishishiba NTAK-1400 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.8
series: NTAK
power_kva: 1400
🏭

Stamford

7 ✓ 7 verifiziert
⚙️
Stamford HC4 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: HC
power_kva: 200
⚙️
Stamford HC5 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: HC
power_kva: 350
⚙️
Stamford HCI4 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: HCI
power_kva: 250
⚙️
Stamford HCI5 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: HCI
power_kva: 400
⚙️
Stamford HCI6 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: HCI
power_kva: 600
⚙️
Stamford PI6 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: PII
power_kva: 800
⚙️
Stamford PI7 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: PII
power_kva: 1200
🏭

Leroy-Somer

6 ✓ 6 verifiziert
⚙️
LSA 46.3 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: LSA
power_kva: 180
⚙️
LSA 47.2 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: LSA
power_kva: 350
⚙️
LSA 49.3 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: LSA
power_kva: 660
⚙️
LSA 50.2 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: LSA
power_kva: 950
⚙️
LSA 52.3 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: LSA
power_kva: 1400
⚙️
LSA 53.1 ✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.85
series: LSA
power_kva: 2000
🏭

Caterpillar / MaK

1 ✓ 1 verifiziert
⚙️
Marine Generator Set ✓ verifiziert PREMIUM
200-10,000 kW · Electrical Power Generation
Voltage: 400V-11kV
type: Diesel Generator Set (Marine)
size_range: ['C18', 'C32', '3512', '3516', 'MaK M20', 'MaK M25', 'MaK M32']
power_range_kw: [200, 10000]
variant_count_approx: 7
period_start_year: 1970
period_end_year: None
drive_type: Diesel Engine + Generator
construction: Medium-speed diesel engine, brushless alternator, base frame, vibration mounts
Common Failures:
  • • Fuel injector nozzle wear after 8,000-12,000 hrs
  • • Turbocharger bearing failure
  • • Generator bearing insulation breakdown
  • • AVR (Automatic Voltage Regulator) failure
  • • Governor hunting/instability
Service: Engine maintenance per Cat/MaK manual (oil change 500-1,000 hrs, injectors 8,000-12,000 hrs, top overhaul 24,000 hrs, major overhaul 48,000 hrs). Generator insulation test annually. AVR calibration annually.
Spares: Caterpillar global network. Lead time: 1-4 weeks for standard parts. Engine overhaul kits: 4-8 weeks.
🏭

MAN Energy Solutions

1 ✓ 1 verifiziert
⚙️
MAN Genset (L16/L21/L27/L32/L35) ✓ verifiziert Inspector
500-10,000 kW · Electrical Power Generation
Voltage: 400V-11kV
type: Diesel Generator Set
size_range: ['L16/24', 'L21/31', 'L27/38', 'L32/44CR', 'L35/44DF']
power_range_kw: [500, 10000]
variant_count_approx: 5
period_start_year: 1980
period_end_year: None
drive_type: Diesel / Dual-Fuel Engine + Generator
construction: Medium-speed 4-stroke engine, brushless alternator
Common Failures:
  • • Common Rail system issues (CR models)
  • • Turbocharger failure
  • • Cylinder head cracking on older models
  • • Generator AVR failure
  • • Dual-fuel gas valve issues (DF models)
Service: Per MAN ES maintenance schedule. Similar intervals to Wärtsilä.
Spares: MAN PrimeServ global. Lead time: 1-4 weeks.
🏭

Wärtsilä

1 ✓ 1 verifiziert
Wärtsilä Wärtsilä Genset (W20/W26/W32/W46)
Wärtsilä Genset (W20/W26/W32/W46) ✓ verifiziert Inspector
500-20,000 kW · Electrical Power Generation
Voltage: 400V-11kV
type: Diesel / Dual-Fuel Generator Set
size_range: ['W20', 'W26', 'W32', 'W34DF', 'W46F', 'W50DF']
power_range_kw: [500, 20000]
variant_count_approx: 6
period_start_year: 1980
period_end_year: None
drive_type: Diesel / Dual-Fuel Engine + Generator
construction: Medium-speed 4-stroke engine, brushless alternator
Common Failures:
  • • Fuel injection system issues
  • • Turbocharger bearing wear
  • • Cylinder liner wear
  • • Generator winding insulation
  • • Dual-fuel gas admission valve failure (DF models)
Service: Per Wärtsilä maintenance schedule. Oil change 500-1,000 hrs. Injectors 6,000-12,000 hrs. Top overhaul 18,000-24,000 hrs. Major overhaul 36,000-48,000 hrs.
Spares: Wärtsilä global (130+ countries). Lead time: 1-4 weeks.