Thermal Oil Heater
medium
88 Modelle gesamt
Known Models (88)
⚙️
Alfa Laval Aalborg Aalborg TFO
verified_specs: {'Type': 'Double coil bare tube, three-pass flue gas configuration', 'Capacity Range': '100-20,000 kW', 'Execution': 'Vertical or horizontal', 'Fuel Options': 'Oil, gas, or dual-fuel', 'Burner Types': 'Monoblock pressure jet burner or rotary cup burner', 'Design Features': 'Removable top plate for inspection/cleaning; high efficiency; heavy insulation'}
application: Oil- or gas-fired thermal fluid heater for marine and industrial thermal oil heating systems (mineral oil, hot water, water/glycol)
model_source: https://www.alfalaval.us/products/heat-transfer/heaters/oil-gas-fired-thermal-heaters/aalborg-tfo/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Aalborg EX
verified_specs: {'Type': 'Exhaust gas economizer for thermal fluid heating', 'Capacity Range': '100-5,000 kW', 'Design Temperature': '280 degrees Celsius', 'Heat Transfer Medium': 'Mineral oils or water', 'Configuration': 'Forced circulation vertical with up to nine coils of bare tubes', 'Features': 'Customizable bypass damper; soot-cleaning water spray nozzles; firefighting water-spray system'}
application: Waste heat recovery heater - Forced-circulation vertical heater for recovering heat from exhaust gases into closed-loop thermal oil systems
model_source: https://www.alfalaval.com/products/heat-transfer/heaters/waste-heat-recovery-heater/aalborg-ex/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Aalborg EH
verified_specs: {'Type': 'Electric thermal fluid/oil heater', 'Capacity Range': '5-233 kW', 'Design Pressure': 'Up to 16 bar(g)', 'Design Temperature': '160°C', 'Application': 'Versatile booster, auxiliary oil and water heating'}
application: Flow-through electric heater for oil heating, booster and auxiliary heating applications in marine and industrial systems
model_source: https://www.alfalaval.us/products/heat-transfer/tubular-heat-exchangers/shell-and-tube-heat-exchangers/aalborg-eh/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Garioni Naval Model TH
verified_specs: {'Capacity Range': '150,000 - 7,000,000 kcal/h', 'Power Range': '83 - 10,000 kW', 'Operating Temperature': 'Up to 320°C (special versions up to 400°C)', 'Configuration': 'Horizontal and vertical versions, 3-pass coil design, multilobular spirally rolled furnace', 'Burner Compatibility': 'Compatible with any type of commercial burner, flexible fuel options', 'Key Features': 'Compact dimensions, quick startup, maximum operational safety, engineered for maximum efficiency without air preheater, low maintenance requirements'}
application: Industrial thermal oil heating for horizontal and vertical installations, suitable for petrochemical, food, chemical, pharmaceutical, paper, textile, steel, glass, and plastic industries
model_source: https://www.garioninaval.com/en/industrial-boilers/thermal-oil-heaters/model-th/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Garioni Naval Model TH/AR
verified_specs: {'Capacity Range': '150,000 - 7,000,000 kcal/h', 'Power Range': '1,744 - 10,000 kW', 'Operating Temperature': 'Up to 320°C (with special versions up to 340°C)', 'Thermal Efficiency': 'Greater than 93%, up to 94% with heat recovery', 'Heat Recovery System': 'Smoke/air exchanger with combustion air preheating using flue gas residual heat', 'Configuration': 'Horizontal and vertical versions with automatic flue damper for constant flue temperature control', 'Advanced Features': 'Automatic flue damper maintains flue temperature constant regardless of heater load, protection against low-temperature corrosion'}
application: High-efficiency industrial thermal oil heating with combustion air preheating system, for heat recovery applications in industrial processes
model_source: https://www.garioninaval.com/en/industrial-boilers/thermal-oil-heaters/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Garioni Naval Model TH/V
verified_specs: {'Capacity Range': '100,000 - 8,000,000 Kcal/h', 'Power Range': '83 - 10,000 kW', 'Operating Temperature': 'Up to 340°C', 'Configuration': 'Vertical version only, coil-fired diathermic oil boiler design', 'Burner Type': 'Compatible with every type of commercial burner', 'Design Advantage': 'Engineered for maximum efficiency without feed air preheater, saves space in vertical installations'}
application: Vertical installation thermal oil heater for space-constrained industrial applications
model_source: https://www.energy-xprt.com/products/garioni-naval-model-th-th-v-thermal-oil-heather-296527
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Garioni Naval Model GEO
verified_specs: {'Power Range': '10 - 500 kW with variable capacity', 'Operating Temperature': 'Up to 320°C (maximum design temperature)', 'Maximum Pressure': '10 barg (bar gauge)', 'Heating Element Configuration': 'One or more electrical resistors with automatic regulation and staged control', 'Standard Features': 'Complete with accessories, control panel, base, external insulation, and automatic temperature regulation', 'Advantages': 'No combustion required, clean operation, precise temperature control, suitable for heat transfer fluid applications'}
application: Electric thermal oil heating for industrial processes requiring automated, clean heating without combustion burners
model_source: https://www.garioninaval.com/en/industrial-boilers/thermal-oil-heaters/model-geo/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc GFT-010
verified_specs: {'Power Range': '116-175 kW (100,000-150,000 kcal/h)', 'Design Pressure': '8 bar', 'Max Service Pressure': '7 bar', 'Design Temperature': '400°C', 'Service Temperature': '350°C', 'Coils': '2', 'Smoke Passes': '3', 'Thermal Efficiency': '87-91%'}
application: Industrial thermal oil heating, thermal fluid processes
model_source: https://www.pirobloc.com/en/products/thermal-oil-heaters/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc GFT-020
verified_specs: {'Power Range': '233-350 kW (200,000-300,000 kcal/h)', 'Design Pressure': '8 bar', 'Max Service Pressure': '7 bar', 'Design Temperature': '400°C', 'Service Temperature': '350°C', 'Coils': '2', 'Smoke Passes': '3', 'Thermal Efficiency': '87-91%'}
application: Industrial thermal oil heating, thermal fluid processes
model_source: https://www.pirobloc.com/en/products/thermal-oil-heaters/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc GFT-030
verified_specs: {'Power Range': '350-465 kW (300,000-400,000 kcal/h)', 'Design Pressure': '8 bar', 'Max Service Pressure': '7 bar', 'Design Temperature': '400°C', 'Service Temperature': '350°C', 'Coils': '2', 'Smoke Passes': '3', 'Thermal Efficiency': '87-91%'}
application: Industrial thermal oil heating, thermal fluid processes
model_source: https://www.pirobloc.com/en/products/thermal-oil-heaters/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc GFT-040
verified_specs: {'Power Range': '465-640 kW (400,000-550,000 kcal/h)', 'Design Pressure': '8 bar', 'Max Service Pressure': '7 bar', 'Design Temperature': '400°C', 'Service Temperature': '350°C', 'Coils': '2', 'Smoke Passes': '3', 'Thermal Efficiency': '87-91%'}
application: Industrial thermal oil heating, thermal fluid processes
model_source: https://www.pirobloc.com/en/products/thermal-oil-heaters/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc GFT-060
verified_specs: {'Power Range': '756-990 kW (650,000-850,000 kcal/h)', 'Design Pressure': '8 bar', 'Max Service Pressure': '7 bar', 'Design Temperature': '400°C', 'Service Temperature': '350°C', 'Coils': '2', 'Smoke Passes': '3', 'Thermal Efficiency': '87-91%'}
application: Industrial thermal oil heating, thermal fluid processes
model_source: https://www.pirobloc.com/en/products/thermal-oil-heaters/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc GFT-090
verified_specs: {'Power Range': '1,050-1,500 kW (900,000-1,300,000 kcal/h)', 'Design Pressure': '8 bar', 'Max Service Pressure': '7 bar', 'Design Temperature': '400°C', 'Service Temperature': '350°C', 'Coils': '2', 'Smoke Passes': '3', 'Thermal Efficiency': '87-91%'}
application: Industrial thermal oil heating, thermal fluid processes
model_source: https://www.pirobloc.com/en/products/thermal-oil-heaters/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc GFT-130
verified_specs: {'Power Range': '1,600-2,040 kW (1,400,000-1,800,000 kcal/h)', 'Design Pressure': '8 bar', 'Max Service Pressure': '7 bar', 'Design Temperature': '400°C', 'Service Temperature': '350°C', 'Coils': '2', 'Smoke Passes': '3', 'Thermal Efficiency': '87-91%'}
application: Industrial thermal oil heating, thermal fluid processes
model_source: https://www.pirobloc.com/en/products/thermal-oil-heaters/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc GFT-170
verified_specs: {'Power Range': '2,300-2,700 kW (2,000,000-2,300,000 kcal/h)', 'Design Pressure': '8 bar', 'Max Service Pressure': '7 bar', 'Design Temperature': '400°C', 'Service Temperature': '350°C', 'Coils': '2', 'Smoke Passes': '3', 'Thermal Efficiency': '87-91%'}
application: Industrial thermal oil heating, thermal fluid processes
model_source: https://www.pirobloc.com/en/products/thermal-oil-heaters/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc GFT-200
verified_specs: {'Power Range': '2,900-3,300 kW (2,500,000-2,800,000 kcal/h)', 'Design Pressure': '8 bar', 'Max Service Pressure': '7 bar', 'Design Temperature': '400°C', 'Service Temperature': '350°C', 'Coils': '2', 'Smoke Passes': '3', 'Thermal Efficiency': '87-91%'}
application: Industrial thermal oil heating, thermal fluid processes
model_source: https://www.pirobloc.com/en/products/thermal-oil-heaters/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc GFT-300
verified_specs: {'Power Range': '3,500-4,070 kW (3,000,000-3,500,000 kcal/h)', 'Design Pressure': '8 bar', 'Max Service Pressure': '7 bar', 'Design Temperature': '400°C', 'Service Temperature': '350°C', 'Coils': '2', 'Smoke Passes': '3', 'Thermal Efficiency': '87-91%'}
application: Industrial thermal oil heating, thermal fluid processes
model_source: https://www.pirobloc.com/en/products/thermal-oil-heaters/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc GFT-400
verified_specs: {'Power Range': '4,651-5,232 kW (4,000,000-5,000,000 kcal/h)', 'Design Pressure': '8 bar', 'Max Service Pressure': '7 bar', 'Design Temperature': '400°C', 'Service Temperature': '350°C', 'Coils': '2', 'Smoke Passes': '3', 'Thermal Efficiency': '87-91%'}
application: Industrial thermal oil heating, thermal fluid processes
model_source: https://www.pirobloc.com/en/products/thermal-oil-heaters/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc GFT-500
verified_specs: {'Power Range': '5,814-6,395 kW (5,000,000-6,000,000 kcal/h)', 'Design Pressure': '8 bar', 'Max Service Pressure': '7 bar', 'Design Temperature': '400°C', 'Service Temperature': '350°C', 'Coils': '2', 'Smoke Passes': '3', 'Thermal Efficiency': '87-91%'}
application: Industrial thermal oil heating, thermal fluid processes
model_source: https://www.pirobloc.com/en/products/thermal-oil-heaters/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc GFT-600
verified_specs: {'Power Range': '6,977-7,558 kW (6,000,000-7,000,000 kcal/h)', 'Design Pressure': '8 bar', 'Max Service Pressure': '7 bar', 'Design Temperature': '400°C', 'Service Temperature': '350°C', 'Coils': '2', 'Smoke Passes': '3', 'Thermal Efficiency': '87-91%'}
application: Industrial thermal oil heating, thermal fluid processes
model_source: https://www.pirobloc.com/en/products/thermal-oil-heaters/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc GFT-800
verified_specs: {'Power Range': '9,300-11,700 kW (8,000,000-10,000,000 kcal/h)', 'Design Pressure': '8 bar', 'Max Service Pressure': '7 bar', 'Design Temperature': '400°C', 'Service Temperature': '350°C', 'Coils': '2', 'Smoke Passes': '3', 'Thermal Efficiency': '87-91%'}
application: Industrial thermal oil heating, thermal fluid processes
model_source: https://www.pirobloc.com/en/products/thermal-oil-heaters/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc CE Series (Electric)
verified_specs: {'Power Range': '25-6,000 kW', 'Standard Range': '24-1,000 kW', 'Operating Pressure (Standard)': '7 bar', 'Test Pressure (Standard)': '16 bar', 'Operating Temperature (Standard)': '300°C', 'Optional Operating Pressure': '20 bar', 'Optional Operating Temperature': '400°C', 'Thermal Efficiency': '100%'}
application: Low power thermal oil heating, electric heating applications
model_source: https://www.pirobloc.com/en/products/thermal-fluid-electric-heater/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc CE-108
verified_specs: {'Maximum Heating Power': '108 kW', 'Operating Pressure': '7 bar', 'Design Pressure': '8 bar', 'Test Pressure': '16 bar', 'Power Stages': '5 warm-up stages', 'Heater Type': 'Low density (3.5 W/cm²)', 'Supply Voltage': '3Ph 400V 50 Hz', 'Thermal Efficiency': '100%'}
application: Electric thermal oil heating, low to medium power applications
model_source: https://www.directindustry.com/prod/pirobloc/product-55730-381045.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc CEV Series (Electric Steam)
verified_specs: {'Power Range': '25-2,500 kW', 'Design Pressure': '9 bar', 'Service Pressure': '8 bar', 'Test Pressure': '16 bar', 'Maximum Service Temperature': '8 bar', 'Configuration': 'Horizontal', 'Thermal Efficiency': '100%', 'Special Features': 'ATEX compliance, stainless steel option, double feed pump'}
application: Electric steam boiler applications, chemical, pharmaceutical, food industries
model_source: https://www.directindustry.com/prod/pirobloc/product-55730-2581892.html
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Pirobloc TPC-B Series
verified_specs: {'Power Range': '116-6,978 kW (100,000-6,000,000 kCal/h)', 'Configuration': 'Vertical, downward-fired', 'Coil Design': 'Stress-free expansion', 'Air Cooling': 'Integral air-cooled outer case', 'Burner': 'Integral Babcock Wanson burner', 'Fuel Options': 'Liquid or gaseous fuels', 'Control System': 'Factory-tested, fully integrated'}
application: Vertical thermal oil heating, downward-fired configuration
model_source: https://www.babcock-wanson.com/products/thermal-fluid-heaters/tpc-b-series/
source: verified_depth_2026-06
source_tag: verified_depth_2026-06
needs_verification: False
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Alfa Laval Aalborg Aalborg TO Series
source: verified_aalborg_type_2026-06
needs_verification: False
catalog_added_at: 2026-05-22T23:39:05
family_name: Aalborg TO
is_family_overview: True
boiler_type: Alfa Laval Aalborg Ölgefeuerte Schiffsdampfkessel (Water Tube / D-Type)
confidence: 0.9
type_specs: {'Dampfkapazität OL': '12.500–55.000 kg/h (mit BOG-Management)', 'Dampfkapazität D': '25–120 t/h (Tanker-Hauptkessel)', 'Designdrücke': '9 oder 18 bar(g)', 'Konstruktion': 'Zweritrommel (Dampftrommel/Wassertrommel), Membranwände, Generatorröhrenbank', 'Rohrsystem': 'Gerade Pin-Tubes mit Schwenk-Pins, externe Fallrohre (Aalborg D)', 'Brenner-Typ': 'Oelgefeuert (Standard), Dual-Fuel optional, KBSD/Aalborg-Brenner', 'Refraktär': 'Minimal im Feuerraum, Isolations- + Formrefraktär an Rohrplatte'}
product_lines: ['Aalborg OL (12.5-55 t/h, 9/18 bar)', 'Aalborg D (25-120 t/h, 18 bar, Tanker-Design)', 'Aalborg OM (8-45 t/h, Mittelkapazität)', 'Mission OS (bis 6 t/h, Vertical Auxiliary)']
datasheet_url: https://datasheets.globalspec.com/ds/alfa-laval/aalborg-ol/0fecddbe-44a9-4c53-98ca-0f7a98222279
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Alfa Laval Aalborg Aalborg TO 1t/7bar
source: verified_aalborg_type_2026-06
needs_verification: False
catalog_added_at: 2026-05-22T23:39:05
family_name: Aalborg TO
is_family_overview: False
boiler_type: Alfa Laval Aalborg Ölgefeuerte Schiffsdampfkessel (Water Tube / D-Type)
steam_capacity_th: 1
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
type_specs: {'Dampfkapazität OL': '12.500–55.000 kg/h (mit BOG-Management)', 'Dampfkapazität D': '25–120 t/h (Tanker-Hauptkessel)', 'Designdrücke': '9 oder 18 bar(g)', 'Konstruktion': 'Zweritrommel (Dampftrommel/Wassertrommel), Membranwände, Generatorröhrenbank', 'Rohrsystem': 'Gerade Pin-Tubes mit Schwenk-Pins, externe Fallrohre (Aalborg D)', 'Brenner-Typ': 'Oelgefeuert (Standard), Dual-Fuel optional, KBSD/Aalborg-Brenner', 'Refraktär': 'Minimal im Feuerraum, Isolations- + Formrefraktär an Rohrplatte'}
product_lines: ['Aalborg OL (12.5-55 t/h, 9/18 bar)', 'Aalborg D (25-120 t/h, 18 bar, Tanker-Design)', 'Aalborg OM (8-45 t/h, Mittelkapazität)', 'Mission OS (bis 6 t/h, Vertical Auxiliary)']
datasheet_url: https://datasheets.globalspec.com/ds/alfa-laval/aalborg-ol/0fecddbe-44a9-4c53-98ca-0f7a98222279
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Alfa Laval Aalborg Aalborg TO 1t/10bar
source: verified_aalborg_type_2026-06
needs_verification: False
catalog_added_at: 2026-05-22T23:39:05
family_name: Aalborg TO
is_family_overview: False
boiler_type: Alfa Laval Aalborg Ölgefeuerte Schiffsdampfkessel (Water Tube / D-Type)
steam_capacity_th: 1
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
type_specs: {'Dampfkapazität OL': '12.500–55.000 kg/h (mit BOG-Management)', 'Dampfkapazität D': '25–120 t/h (Tanker-Hauptkessel)', 'Designdrücke': '9 oder 18 bar(g)', 'Konstruktion': 'Zweritrommel (Dampftrommel/Wassertrommel), Membranwände, Generatorröhrenbank', 'Rohrsystem': 'Gerade Pin-Tubes mit Schwenk-Pins, externe Fallrohre (Aalborg D)', 'Brenner-Typ': 'Oelgefeuert (Standard), Dual-Fuel optional, KBSD/Aalborg-Brenner', 'Refraktär': 'Minimal im Feuerraum, Isolations- + Formrefraktär an Rohrplatte'}
product_lines: ['Aalborg OL (12.5-55 t/h, 9/18 bar)', 'Aalborg D (25-120 t/h, 18 bar, Tanker-Design)', 'Aalborg OM (8-45 t/h, Mittelkapazität)', 'Mission OS (bis 6 t/h, Vertical Auxiliary)']
datasheet_url: https://datasheets.globalspec.com/ds/alfa-laval/aalborg-ol/0fecddbe-44a9-4c53-98ca-0f7a98222279
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Alfa Laval Aalborg Aalborg TO 2t/7bar
source: verified_aalborg_type_2026-06
needs_verification: False
catalog_added_at: 2026-05-22T23:39:05
family_name: Aalborg TO
is_family_overview: False
boiler_type: Alfa Laval Aalborg Ölgefeuerte Schiffsdampfkessel (Water Tube / D-Type)
steam_capacity_th: 2
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
type_specs: {'Dampfkapazität OL': '12.500–55.000 kg/h (mit BOG-Management)', 'Dampfkapazität D': '25–120 t/h (Tanker-Hauptkessel)', 'Designdrücke': '9 oder 18 bar(g)', 'Konstruktion': 'Zweritrommel (Dampftrommel/Wassertrommel), Membranwände, Generatorröhrenbank', 'Rohrsystem': 'Gerade Pin-Tubes mit Schwenk-Pins, externe Fallrohre (Aalborg D)', 'Brenner-Typ': 'Oelgefeuert (Standard), Dual-Fuel optional, KBSD/Aalborg-Brenner', 'Refraktär': 'Minimal im Feuerraum, Isolations- + Formrefraktär an Rohrplatte'}
product_lines: ['Aalborg OL (12.5-55 t/h, 9/18 bar)', 'Aalborg D (25-120 t/h, 18 bar, Tanker-Design)', 'Aalborg OM (8-45 t/h, Mittelkapazität)', 'Mission OS (bis 6 t/h, Vertical Auxiliary)']
datasheet_url: https://datasheets.globalspec.com/ds/alfa-laval/aalborg-ol/0fecddbe-44a9-4c53-98ca-0f7a98222279
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Alfa Laval Aalborg Aalborg TO 2t/10bar
source: verified_aalborg_type_2026-06
needs_verification: False
catalog_added_at: 2026-05-22T23:39:05
family_name: Aalborg TO
is_family_overview: False
boiler_type: Alfa Laval Aalborg Ölgefeuerte Schiffsdampfkessel (Water Tube / D-Type)
steam_capacity_th: 2
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
type_specs: {'Dampfkapazität OL': '12.500–55.000 kg/h (mit BOG-Management)', 'Dampfkapazität D': '25–120 t/h (Tanker-Hauptkessel)', 'Designdrücke': '9 oder 18 bar(g)', 'Konstruktion': 'Zweritrommel (Dampftrommel/Wassertrommel), Membranwände, Generatorröhrenbank', 'Rohrsystem': 'Gerade Pin-Tubes mit Schwenk-Pins, externe Fallrohre (Aalborg D)', 'Brenner-Typ': 'Oelgefeuert (Standard), Dual-Fuel optional, KBSD/Aalborg-Brenner', 'Refraktär': 'Minimal im Feuerraum, Isolations- + Formrefraktär an Rohrplatte'}
product_lines: ['Aalborg OL (12.5-55 t/h, 9/18 bar)', 'Aalborg D (25-120 t/h, 18 bar, Tanker-Design)', 'Aalborg OM (8-45 t/h, Mittelkapazität)', 'Mission OS (bis 6 t/h, Vertical Auxiliary)']
datasheet_url: https://datasheets.globalspec.com/ds/alfa-laval/aalborg-ol/0fecddbe-44a9-4c53-98ca-0f7a98222279
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Alfa Laval Aalborg Aalborg TO 5t/7bar
source: verified_aalborg_type_2026-06
needs_verification: False
catalog_added_at: 2026-05-22T23:39:05
family_name: Aalborg TO
is_family_overview: False
boiler_type: Alfa Laval Aalborg Ölgefeuerte Schiffsdampfkessel (Water Tube / D-Type)
steam_capacity_th: 5
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
type_specs: {'Dampfkapazität OL': '12.500–55.000 kg/h (mit BOG-Management)', 'Dampfkapazität D': '25–120 t/h (Tanker-Hauptkessel)', 'Designdrücke': '9 oder 18 bar(g)', 'Konstruktion': 'Zweritrommel (Dampftrommel/Wassertrommel), Membranwände, Generatorröhrenbank', 'Rohrsystem': 'Gerade Pin-Tubes mit Schwenk-Pins, externe Fallrohre (Aalborg D)', 'Brenner-Typ': 'Oelgefeuert (Standard), Dual-Fuel optional, KBSD/Aalborg-Brenner', 'Refraktär': 'Minimal im Feuerraum, Isolations- + Formrefraktär an Rohrplatte'}
product_lines: ['Aalborg OL (12.5-55 t/h, 9/18 bar)', 'Aalborg D (25-120 t/h, 18 bar, Tanker-Design)', 'Aalborg OM (8-45 t/h, Mittelkapazität)', 'Mission OS (bis 6 t/h, Vertical Auxiliary)']
datasheet_url: https://datasheets.globalspec.com/ds/alfa-laval/aalborg-ol/0fecddbe-44a9-4c53-98ca-0f7a98222279
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Alfa Laval Aalborg Aalborg TO 5t/10bar
source: verified_aalborg_type_2026-06
needs_verification: False
catalog_added_at: 2026-05-22T23:39:05
family_name: Aalborg TO
is_family_overview: False
boiler_type: Alfa Laval Aalborg Ölgefeuerte Schiffsdampfkessel (Water Tube / D-Type)
steam_capacity_th: 5
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
type_specs: {'Dampfkapazität OL': '12.500–55.000 kg/h (mit BOG-Management)', 'Dampfkapazität D': '25–120 t/h (Tanker-Hauptkessel)', 'Designdrücke': '9 oder 18 bar(g)', 'Konstruktion': 'Zweritrommel (Dampftrommel/Wassertrommel), Membranwände, Generatorröhrenbank', 'Rohrsystem': 'Gerade Pin-Tubes mit Schwenk-Pins, externe Fallrohre (Aalborg D)', 'Brenner-Typ': 'Oelgefeuert (Standard), Dual-Fuel optional, KBSD/Aalborg-Brenner', 'Refraktär': 'Minimal im Feuerraum, Isolations- + Formrefraktär an Rohrplatte'}
product_lines: ['Aalborg OL (12.5-55 t/h, 9/18 bar)', 'Aalborg D (25-120 t/h, 18 bar, Tanker-Design)', 'Aalborg OM (8-45 t/h, Mittelkapazität)', 'Mission OS (bis 6 t/h, Vertical Auxiliary)']
datasheet_url: https://datasheets.globalspec.com/ds/alfa-laval/aalborg-ol/0fecddbe-44a9-4c53-98ca-0f7a98222279
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Alfa Laval Aalborg Aalborg TO 10t/7bar
source: verified_aalborg_type_2026-06
needs_verification: False
catalog_added_at: 2026-05-22T23:39:05
family_name: Aalborg TO
is_family_overview: False
boiler_type: Alfa Laval Aalborg Ölgefeuerte Schiffsdampfkessel (Water Tube / D-Type)
steam_capacity_th: 10
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
type_specs: {'Dampfkapazität OL': '12.500–55.000 kg/h (mit BOG-Management)', 'Dampfkapazität D': '25–120 t/h (Tanker-Hauptkessel)', 'Designdrücke': '9 oder 18 bar(g)', 'Konstruktion': 'Zweritrommel (Dampftrommel/Wassertrommel), Membranwände, Generatorröhrenbank', 'Rohrsystem': 'Gerade Pin-Tubes mit Schwenk-Pins, externe Fallrohre (Aalborg D)', 'Brenner-Typ': 'Oelgefeuert (Standard), Dual-Fuel optional, KBSD/Aalborg-Brenner', 'Refraktär': 'Minimal im Feuerraum, Isolations- + Formrefraktär an Rohrplatte'}
product_lines: ['Aalborg OL (12.5-55 t/h, 9/18 bar)', 'Aalborg D (25-120 t/h, 18 bar, Tanker-Design)', 'Aalborg OM (8-45 t/h, Mittelkapazität)', 'Mission OS (bis 6 t/h, Vertical Auxiliary)']
datasheet_url: https://datasheets.globalspec.com/ds/alfa-laval/aalborg-ol/0fecddbe-44a9-4c53-98ca-0f7a98222279
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Alfa Laval Aalborg Aalborg TO 10t/10bar
source: verified_aalborg_type_2026-06
needs_verification: False
catalog_added_at: 2026-05-22T23:39:05
family_name: Aalborg TO
is_family_overview: False
boiler_type: Alfa Laval Aalborg Ölgefeuerte Schiffsdampfkessel (Water Tube / D-Type)
steam_capacity_th: 10
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
type_specs: {'Dampfkapazität OL': '12.500–55.000 kg/h (mit BOG-Management)', 'Dampfkapazität D': '25–120 t/h (Tanker-Hauptkessel)', 'Designdrücke': '9 oder 18 bar(g)', 'Konstruktion': 'Zweritrommel (Dampftrommel/Wassertrommel), Membranwände, Generatorröhrenbank', 'Rohrsystem': 'Gerade Pin-Tubes mit Schwenk-Pins, externe Fallrohre (Aalborg D)', 'Brenner-Typ': 'Oelgefeuert (Standard), Dual-Fuel optional, KBSD/Aalborg-Brenner', 'Refraktär': 'Minimal im Feuerraum, Isolations- + Formrefraktär an Rohrplatte'}
product_lines: ['Aalborg OL (12.5-55 t/h, 9/18 bar)', 'Aalborg D (25-120 t/h, 18 bar, Tanker-Design)', 'Aalborg OM (8-45 t/h, Mittelkapazität)', 'Mission OS (bis 6 t/h, Vertical Auxiliary)']
datasheet_url: https://datasheets.globalspec.com/ds/alfa-laval/aalborg-ol/0fecddbe-44a9-4c53-98ca-0f7a98222279
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Alfa Laval Aalborg Aalborg TO 15t/7bar
source: verified_aalborg_type_2026-06
needs_verification: False
catalog_added_at: 2026-05-22T23:39:05
family_name: Aalborg TO
is_family_overview: False
boiler_type: Alfa Laval Aalborg Ölgefeuerte Schiffsdampfkessel (Water Tube / D-Type)
steam_capacity_th: 15
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
type_specs: {'Dampfkapazität OL': '12.500–55.000 kg/h (mit BOG-Management)', 'Dampfkapazität D': '25–120 t/h (Tanker-Hauptkessel)', 'Designdrücke': '9 oder 18 bar(g)', 'Konstruktion': 'Zweritrommel (Dampftrommel/Wassertrommel), Membranwände, Generatorröhrenbank', 'Rohrsystem': 'Gerade Pin-Tubes mit Schwenk-Pins, externe Fallrohre (Aalborg D)', 'Brenner-Typ': 'Oelgefeuert (Standard), Dual-Fuel optional, KBSD/Aalborg-Brenner', 'Refraktär': 'Minimal im Feuerraum, Isolations- + Formrefraktär an Rohrplatte'}
product_lines: ['Aalborg OL (12.5-55 t/h, 9/18 bar)', 'Aalborg D (25-120 t/h, 18 bar, Tanker-Design)', 'Aalborg OM (8-45 t/h, Mittelkapazität)', 'Mission OS (bis 6 t/h, Vertical Auxiliary)']
datasheet_url: https://datasheets.globalspec.com/ds/alfa-laval/aalborg-ol/0fecddbe-44a9-4c53-98ca-0f7a98222279
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Alfa Laval Aalborg Aalborg TO 15t/10bar
source: verified_aalborg_type_2026-06
needs_verification: False
catalog_added_at: 2026-05-22T23:39:05
family_name: Aalborg TO
is_family_overview: False
boiler_type: Alfa Laval Aalborg Ölgefeuerte Schiffsdampfkessel (Water Tube / D-Type)
steam_capacity_th: 15
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
type_specs: {'Dampfkapazität OL': '12.500–55.000 kg/h (mit BOG-Management)', 'Dampfkapazität D': '25–120 t/h (Tanker-Hauptkessel)', 'Designdrücke': '9 oder 18 bar(g)', 'Konstruktion': 'Zweritrommel (Dampftrommel/Wassertrommel), Membranwände, Generatorröhrenbank', 'Rohrsystem': 'Gerade Pin-Tubes mit Schwenk-Pins, externe Fallrohre (Aalborg D)', 'Brenner-Typ': 'Oelgefeuert (Standard), Dual-Fuel optional, KBSD/Aalborg-Brenner', 'Refraktär': 'Minimal im Feuerraum, Isolations- + Formrefraktär an Rohrplatte'}
product_lines: ['Aalborg OL (12.5-55 t/h, 9/18 bar)', 'Aalborg D (25-120 t/h, 18 bar, Tanker-Design)', 'Aalborg OM (8-45 t/h, Mittelkapazität)', 'Mission OS (bis 6 t/h, Vertical Auxiliary)']
datasheet_url: https://datasheets.globalspec.com/ds/alfa-laval/aalborg-ol/0fecddbe-44a9-4c53-98ca-0f7a98222279
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Alfa Laval Aalborg TF-300 Series
source: verified_aalborg_type_2026-06
needs_verification: False
catalog_added_at: 2026-05-22T23:39:05
family_name: TF-300
is_family_overview: True
boiler_type: Alfa Laval Aalborg Ölgefeuerte Schiffsdampfkessel (Water Tube / D-Type)
confidence: 0.9
type_specs: {'Dampfkapazität OL': '12.500–55.000 kg/h (mit BOG-Management)', 'Dampfkapazität D': '25–120 t/h (Tanker-Hauptkessel)', 'Designdrücke': '9 oder 18 bar(g)', 'Konstruktion': 'Zweritrommel (Dampftrommel/Wassertrommel), Membranwände, Generatorröhrenbank', 'Rohrsystem': 'Gerade Pin-Tubes mit Schwenk-Pins, externe Fallrohre (Aalborg D)', 'Brenner-Typ': 'Oelgefeuert (Standard), Dual-Fuel optional, KBSD/Aalborg-Brenner', 'Refraktär': 'Minimal im Feuerraum, Isolations- + Formrefraktär an Rohrplatte'}
product_lines: ['Aalborg OL (12.5-55 t/h, 9/18 bar)', 'Aalborg D (25-120 t/h, 18 bar, Tanker-Design)', 'Aalborg OM (8-45 t/h, Mittelkapazität)', 'Mission OS (bis 6 t/h, Vertical Auxiliary)']
datasheet_url: https://datasheets.globalspec.com/ds/alfa-laval/aalborg-ol/0fecddbe-44a9-4c53-98ca-0f7a98222279
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Alfa Laval Aalborg TF-300 0.5t/7bar
source: verified_aalborg_type_2026-06
needs_verification: False
catalog_added_at: 2026-05-22T23:39:05
family_name: TF-300
is_family_overview: False
boiler_type: Alfa Laval Aalborg Ölgefeuerte Schiffsdampfkessel (Water Tube / D-Type)
steam_capacity_th: 0.5
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
type_specs: {'Dampfkapazität OL': '12.500–55.000 kg/h (mit BOG-Management)', 'Dampfkapazität D': '25–120 t/h (Tanker-Hauptkessel)', 'Designdrücke': '9 oder 18 bar(g)', 'Konstruktion': 'Zweritrommel (Dampftrommel/Wassertrommel), Membranwände, Generatorröhrenbank', 'Rohrsystem': 'Gerade Pin-Tubes mit Schwenk-Pins, externe Fallrohre (Aalborg D)', 'Brenner-Typ': 'Oelgefeuert (Standard), Dual-Fuel optional, KBSD/Aalborg-Brenner', 'Refraktär': 'Minimal im Feuerraum, Isolations- + Formrefraktär an Rohrplatte'}
product_lines: ['Aalborg OL (12.5-55 t/h, 9/18 bar)', 'Aalborg D (25-120 t/h, 18 bar, Tanker-Design)', 'Aalborg OM (8-45 t/h, Mittelkapazität)', 'Mission OS (bis 6 t/h, Vertical Auxiliary)']
datasheet_url: https://datasheets.globalspec.com/ds/alfa-laval/aalborg-ol/0fecddbe-44a9-4c53-98ca-0f7a98222279
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Alfa Laval Aalborg TF-300 1t/7bar
source: verified_aalborg_type_2026-06
needs_verification: False
catalog_added_at: 2026-05-22T23:39:05
family_name: TF-300
is_family_overview: False
boiler_type: Alfa Laval Aalborg Ölgefeuerte Schiffsdampfkessel (Water Tube / D-Type)
steam_capacity_th: 1
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
type_specs: {'Dampfkapazität OL': '12.500–55.000 kg/h (mit BOG-Management)', 'Dampfkapazität D': '25–120 t/h (Tanker-Hauptkessel)', 'Designdrücke': '9 oder 18 bar(g)', 'Konstruktion': 'Zweritrommel (Dampftrommel/Wassertrommel), Membranwände, Generatorröhrenbank', 'Rohrsystem': 'Gerade Pin-Tubes mit Schwenk-Pins, externe Fallrohre (Aalborg D)', 'Brenner-Typ': 'Oelgefeuert (Standard), Dual-Fuel optional, KBSD/Aalborg-Brenner', 'Refraktär': 'Minimal im Feuerraum, Isolations- + Formrefraktär an Rohrplatte'}
product_lines: ['Aalborg OL (12.5-55 t/h, 9/18 bar)', 'Aalborg D (25-120 t/h, 18 bar, Tanker-Design)', 'Aalborg OM (8-45 t/h, Mittelkapazität)', 'Mission OS (bis 6 t/h, Vertical Auxiliary)']
datasheet_url: https://datasheets.globalspec.com/ds/alfa-laval/aalborg-ol/0fecddbe-44a9-4c53-98ca-0f7a98222279
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Alfa Laval Aalborg TF-300 2t/7bar
source: verified_aalborg_type_2026-06
needs_verification: False
catalog_added_at: 2026-05-22T23:39:05
family_name: TF-300
is_family_overview: False
boiler_type: Alfa Laval Aalborg Ölgefeuerte Schiffsdampfkessel (Water Tube / D-Type)
steam_capacity_th: 2
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
type_specs: {'Dampfkapazität OL': '12.500–55.000 kg/h (mit BOG-Management)', 'Dampfkapazität D': '25–120 t/h (Tanker-Hauptkessel)', 'Designdrücke': '9 oder 18 bar(g)', 'Konstruktion': 'Zweritrommel (Dampftrommel/Wassertrommel), Membranwände, Generatorröhrenbank', 'Rohrsystem': 'Gerade Pin-Tubes mit Schwenk-Pins, externe Fallrohre (Aalborg D)', 'Brenner-Typ': 'Oelgefeuert (Standard), Dual-Fuel optional, KBSD/Aalborg-Brenner', 'Refraktär': 'Minimal im Feuerraum, Isolations- + Formrefraktär an Rohrplatte'}
product_lines: ['Aalborg OL (12.5-55 t/h, 9/18 bar)', 'Aalborg D (25-120 t/h, 18 bar, Tanker-Design)', 'Aalborg OM (8-45 t/h, Mittelkapazität)', 'Mission OS (bis 6 t/h, Vertical Auxiliary)']
datasheet_url: https://datasheets.globalspec.com/ds/alfa-laval/aalborg-ol/0fecddbe-44a9-4c53-98ca-0f7a98222279
Common Failures:
- • _hinweis
- • items
⚙️
Alfa Laval Aalborg Alfa Laval Aalborg TF-300 5t/7bar
source: verified_aalborg_type_2026-06
needs_verification: False
catalog_added_at: 2026-05-22T23:39:05
family_name: TF-300
is_family_overview: False
boiler_type: Alfa Laval Aalborg Ölgefeuerte Schiffsdampfkessel (Water Tube / D-Type)
steam_capacity_th: 5
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
type_specs: {'Dampfkapazität OL': '12.500–55.000 kg/h (mit BOG-Management)', 'Dampfkapazität D': '25–120 t/h (Tanker-Hauptkessel)', 'Designdrücke': '9 oder 18 bar(g)', 'Konstruktion': 'Zweritrommel (Dampftrommel/Wassertrommel), Membranwände, Generatorröhrenbank', 'Rohrsystem': 'Gerade Pin-Tubes mit Schwenk-Pins, externe Fallrohre (Aalborg D)', 'Brenner-Typ': 'Oelgefeuert (Standard), Dual-Fuel optional, KBSD/Aalborg-Brenner', 'Refraktär': 'Minimal im Feuerraum, Isolations- + Formrefraktär an Rohrplatte'}
product_lines: ['Aalborg OL (12.5-55 t/h, 9/18 bar)', 'Aalborg D (25-120 t/h, 18 bar, Tanker-Design)', 'Aalborg OM (8-45 t/h, Mittelkapazität)', 'Mission OS (bis 6 t/h, Vertical Auxiliary)']
datasheet_url: https://datasheets.globalspec.com/ds/alfa-laval/aalborg-ol/0fecddbe-44a9-4c53-98ca-0f7a98222279
Common Failures:
- • _hinweis
- • items
⚙️
Babcock Wanson Babcock Wanson BW-TO Series
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: BW-TO
is_family_overview: True
boiler_type: thermal_oil_heater
confidence: 0.9
⚙️
Babcock Wanson Babcock Wanson BW-TO 1t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: BW-TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 1
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Babcock Wanson Babcock Wanson BW-TO 1t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: BW-TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 1
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Babcock Wanson Babcock Wanson BW-TO 2t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: BW-TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 2
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Babcock Wanson Babcock Wanson BW-TO 2t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: BW-TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 2
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Babcock Wanson Babcock Wanson BW-TO 5t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: BW-TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 5
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Babcock Wanson Babcock Wanson BW-TO 5t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: BW-TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 5
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Babcock Wanson Babcock Wanson BW-TO 10t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: BW-TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 10
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Babcock Wanson Babcock Wanson BW-TO 10t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: BW-TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 10
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Babcock Wanson Babcock Wanson BW-TO 15t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: BW-TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 15
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Babcock Wanson Babcock Wanson BW-TO 15t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: BW-TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 15
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Garioni Naval Garioni Naval GTO Series
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: GTO
is_family_overview: True
boiler_type: thermal_oil_heater
confidence: 0.9
⚙️
Garioni Naval Garioni Naval GTO 1t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: GTO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 1
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Garioni Naval Garioni Naval GTO 1t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: GTO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 1
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Garioni Naval Garioni Naval GTO 2t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: GTO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 2
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Garioni Naval Garioni Naval GTO 2t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: GTO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 2
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Garioni Naval Garioni Naval GTO 5t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: GTO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 5
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Garioni Naval Garioni Naval GTO 5t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: GTO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 5
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Garioni Naval Garioni Naval GTO 10t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: GTO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 10
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Garioni Naval Garioni Naval GTO 10t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: GTO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 10
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Kangrim Kangrim KTO Series
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: KTO
is_family_overview: True
boiler_type: thermal_oil_heater
confidence: 0.9
⚙️
Kangrim Kangrim KTO 1t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: KTO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 1
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Kangrim Kangrim KTO 1t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: KTO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 1
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Kangrim Kangrim KTO 2t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: KTO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 2
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Kangrim Kangrim KTO 2t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: KTO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 2
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Kangrim Kangrim KTO 5t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: KTO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 5
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Kangrim Kangrim KTO 5t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: KTO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 5
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Kangrim Kangrim KTO 10t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: KTO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 10
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Kangrim Kangrim KTO 10t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: KTO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 10
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Saacke Saacke TYP TO Series
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TYP TO
is_family_overview: True
boiler_type: thermal_oil_heater
confidence: 0.9
⚙️
Saacke Saacke TYP TO 1t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TYP TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 1
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Saacke Saacke TYP TO 1t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TYP TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 1
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Saacke Saacke TYP TO 2t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TYP TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 2
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Saacke Saacke TYP TO 2t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TYP TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 2
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Saacke Saacke TYP TO 5t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TYP TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 5
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Saacke Saacke TYP TO 5t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TYP TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 5
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Saacke Saacke TYP TO 10t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TYP TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 10
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Saacke Saacke TYP TO 10t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TYP TO
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 10
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Sunrod Sunrod TOH Series
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TOH
is_family_overview: True
boiler_type: thermal_oil_heater
confidence: 0.9
⚙️
Sunrod Sunrod TOH 1t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TOH
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 1
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Sunrod Sunrod TOH 1t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TOH
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 1
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Sunrod Sunrod TOH 2t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TOH
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 2
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Sunrod Sunrod TOH 2t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TOH
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 2
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Sunrod Sunrod TOH 5t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TOH
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 5
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Sunrod Sunrod TOH 5t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TOH
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 5
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Sunrod Sunrod TOH 10t/7bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TOH
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 10
design_pressure_bar: 7
fuel_type: HFO/MDO
confidence: 0.86
⚙️
Sunrod Sunrod TOH 10t/10bar
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:39:05
family_name: TOH
is_family_overview: False
boiler_type: thermal_oil_heater
steam_capacity_th: 10
design_pressure_bar: 10
fuel_type: HFO/MDO
confidence: 0.86