CO₂ Fixed System (Engine Room + Cargo)
critical
IMO Required
887 Modelle gesamt
Fixed CO₂ total-flooding fire extinguishing system per SOLAS II-2.
8760h
Service Interval
Typical Manufacturers
Kidde
Viking
Unitor
Marioff
290 Hersteller · 887 Modelle
🏭
Kidde
4 ✓ 4 verifiziert⚙️
Kidde CO₂ Total Flooding System
✓ verifiziert
Inspector
Engine room / cargo hold coverage
· Fire Suppression / Detection
Common Failures:
- • Pilot cylinder pressure loss
- • Distribution valve seat leak
- • Cable-operated release mechanism seizure
Service: Cylinder weighing every 2 years. Pilot cylinder hydrostatic test every 10 years. Full system function test at annual survey.
Spares: Kidde: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.
⚙️
Kidde CO2 Bulk System ER
✓ verifiziert
equipment_type: fire_suppression
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.7
solas_type: SOLAS
engine room bulk CO2
⚙️
Kidde CO2 Cylinder Bank System
✓ verifiziert
equipment_type: fire_suppression
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.7
solas_type: SOLAS
cylinder bank CO2
⚙️
Kidde CO2 Cargo Hold System
✓ verifiziert
equipment_type: fire_suppression
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.7
solas_type: SOLAS
cargo hold CO2
🏭
Unitor
1 ✓ 1 verifiziert⚙️
Unitor CO₂ Fixed Fire Extinguishing System
✓ verifiziert
Inspector
Modular 45 kg cylinders
· Fire Suppression / Detection
Common Failures:
- • Release cabinet interlock failure
- • Nozzle blockage by paint/corrosion
- • Time delay mechanism malfunction
Service: Annual function test of release mechanism. Nozzle inspection at dry-dock. Alarm/ventilation interlock test quarterly.
Spares: Unitor: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.
🏭
Siemens Industry
37⚙️
Desigo Fire Safety and Cerberus PRO
source: uscg-cgmix
model_number: 161.002/60/0
⚙️
PAD-4 fire detection system expander with the following accessories are approved for use in Category 1 & 3 spaces when installed with P4AP mount and FH2071-UM enclosure. Includes optional PAD-4-CLSA NAC Extender Card.
source: uscg-cgmix
model_number: 161.002/62/0
⚙️
XMS-M approved as a manual signaling box for fire detection systems, for use in Category 1, 2, & 3 spaces.
source: uscg-cgmix
model_number: 161.002/63/0
⚙️
ABHW-4B approved as an audible signal notification device for fire detection systems for use in Category 1, 2, & 3 spaces.
source: uscg-cgmix
model_number: 161.002/64/0
⚙️
XTRI-D, XTRI-R, XTRI-S, & XTRI-M interface and isolator modules for fire detection systems. Approved for use in Category 1, 2, & 3 spaces.
source: uscg-cgmix
model_number: 161.002/65/0
⚙️
ILED-XC, ILED-XW remote lamp, device loop indicator modules for fire detection systems. Approved for use in Category 1, 2, & 3 spaces.
source: uscg-cgmix
model_number: 161.002/66/0
⚙️
TSM-1X test switch module for fire detection systems approved for use in Category 1, 2, & 3 spaces.
source: uscg-cgmix
model_number: 161.002/67/0
⚙️
FC20xx (Desigo) and FC92x (Cerberus) series fire detection system control panel and control panel accessories are approved for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/72/0
⚙️
PAD-5 series of fire detection system control panel and control panel accessories are approved for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/73/0
⚙️
FT2014-xx, and FT2015-xx series of remote annunciators and control panels for fire detection system are approved for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/74/0
⚙️
DB-11, DB2 series detector bases, seals, and relays are approved as a fire detection system accessory, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/75/0
⚙️
FDCIO422, TB-EOL, and FDCIO-EOL series of interface modules and end of the line devices, are approved as a fire detection system accessory, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/76/0
⚙️
HZM remote conventional zone module is approved as a fire detection system accessory, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/77/0
⚙️
HTRI-S, HTRI-D, HTRI-R addressable switch interface modules are approved as a fire detection system accessory, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/78/0
⚙️
HTRI-M addressable interface module is approved as a fire detection system accessory, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/79/0
⚙️
SMBOX-XMP, WPSBBS, WPBBS series surface mount boxes, and 4DGBOX, ALPT-XMP adapter plates are approved as a fire detection system accessories, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/80/0
⚙️
HMS-M approved as a manual signaling box, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/81/0
⚙️
MSM-K, MSM-KD, MSM-EXP, MSM-INST series products approved as a manual signaling boxes, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/82/0
⚙️
FD0421 and OP921 approved as a smoke detector, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/83/0
⚙️
OP121 approved as a smoke detector, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/84/0
⚙️
FDT421 and HI921 approved as a heat detector, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/85/0
⚙️
HI121 approved as a heat detector, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/86/0
⚙️
DT-135 WP and DT-200WP approved as a heat detector, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/87/0
⚙️
DT-140EP and DT-190EP approved as a heat detector, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/88/0
⚙️
FDOOT441 and OOH941 approved as all of the following; heat detector, smoke detector, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/89/0
⚙️
FDOOTC441 and OOHC941 approved as all of the following; heat detector, smoke detector, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/90/0
⚙️
FDOT421 and OH921 approved as all of the following; heat detector, smoke detector, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/91/0
⚙️
OH121 approved as all of the following; heat detector, smoke detector, for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/92/0
⚙️
MDBC-x series of motor bells approved as an audible signal notification device for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/93/0
⚙️
SLHCR and SLHWR series of horns approved as an audible signal notification device for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/94/0
⚙️
ST-75-x-WP, and ST-HMC-x-WP series of strobes approved as a visual alarm notification device for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/95/0
⚙️
SLSW and SLSC series of strobes approved as a visual alarm notification device for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/96/0
⚙️
ZH-MC-x, ZH-HMC-x series of horn/strobes approved as an audible alarm signal notification device and visual notification device for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/97/0
⚙️
SLHSC series of horn/strobes approved as an audible alarm signal notification device and visual notification device for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/98/0
⚙️
AS-75-x-WP series of weatherproof horn/strobes approved as an audible alarm signal notification device and visual notification device for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/99/0
⚙️
ZH-x series of horns approved as an audible signal notification device for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/100/0
⚙️
ZR-MC-x and ZR-HMC-x series of strobes approved as a visual alarm notification device for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/101/0
🏭
Podszuck
29⚙️
Class A-60 double leaf hinged fire door type "LMD-HD-ROH"
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006SE
⚙️
Class A-60 single leaf hinged fire door type "LMD-HS-NR-60"
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000056X
⚙️
Class A-60 double leaf hinged fire door type "LMD-HD-NR"
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006SF
⚙️
Class A-30 single leaf hinged fire door type "LMD-HS-NR-30"
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000056Y
⚙️
Class A-60 single leaf sliding fire door type "LMD-SL-R-G"
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000601
⚙️
Class A-60 single leaf hinged fire door type "LMD-HS-R-G"
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00000YH
⚙️
Class A-60 double leaf hinged fire door type "LMD-HD-RO-G"
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00000YF
⚙️
Class A-30 single leaf hinged fire door type "LMD-Poki-L (40)"
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000056Z
⚙️
Class A-60 double leaf sliding fire door type "LMD-SL-D"
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000600
⚙️
Class A-60 single leaf hinged fire door type "LMD-HSL 1"
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004HH
⚙️
Class A-30 single leaf hinged fire door type "LMD-HSL 1-30"
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004HG
⚙️
LMD-H1 Class A-60 Single Leaf Hinged Fire Door LMD-H1-G Class A-60 Single Leaf Hinged Fire Door with Glass
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00002A9
⚙️
LMD-SL-LORIS 1 Class A-60 Single Leaf Sliding Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00000YK
⚙️
Double leaf hinged fire door type "LMD - HD - NR"
source: dnv-approval-finder
model_number: TAF00001BH
⚙️
LMD-H1 Class A-60 Single Leaf Hinged Fire Door, LMD-H1-G Class A-60 Single Leaf Hinged Fire Door with Glass
source: dnv-approval-finder
model_number: TAF00001BJ
⚙️
"LMD-HD-NR" double-leaf hinged fire door with hose port tested and approved as Class A-60 in accordance with Annex 1, Part 3 of the IMO 2010 FTP Code.
source: uscg-cgmix
model_number: 164.136/63/1
⚙️
"LMD-HS-NR-60" single-leaf hinged fire door with hose port tested and approved as Class A-60 in accordance with Annex 1, Part 3 of the IMO 2010 FTP Code.
source: uscg-cgmix
model_number: 164.136/64/1
⚙️
"LMD-VSF-2" is a double-leaf vertical sliding fire door tested and approved as Class A-60 in accordance with Annex 1, Part 3 of the IMO 2010 FTP Code.
source: uscg-cgmix
model_number: 164.136/71/0
⚙️
"LMD-H1-W" is a Class A-60 singled leaf hinged fire door with window tested and approved in accordance with IMO FTP Code, Annex 1, Part 3.
source: uscg-cgmix
model_number: 164.136/80/0
⚙️
"LMD-HD-RO" is a Class A-60 double leaf hinged door tested and approved in accordance with IMO FTP Code Annex 1, Part 3.
source: uscg-cgmix
model_number: 164.136/99/0
⚙️
"LMD-H1" single leaf hinged fire door tested and approved as Class A-60 in accordance with Annex 1, Part 3 of the IMO FTP Code.
source: uscg-cgmix
model_number: 164.136/107/0
⚙️
"LMD-HS-R/G" single leaf hinged fire door tested and approved as Class A-60 in accordance with Annex 1, Part 3 of the IMO FTP Code.
source: uscg-cgmix
model_number: 164.136/108/0
⚙️
"LMD-SL-D" double-leaf sliding fire door with optional hose port tested and approved as Class A-60 in accordance with Annex 1, Part 3 of the IMO 2010 FTP Code.
source: uscg-cgmix
model_number: 164.136/110/0
⚙️
"LMD-SL-R-G" single-leaf sliding fire door with optional window and hose port tested and approved as Class A-60 in accordance with Annex 1, Part 3 of the IMO 2010 FTP Code.
source: uscg-cgmix
model_number: 164.136/111/0
⚙️
"LMD-HD-RO-G" double-leaf hinged fire door with optional window tested and approved as Class A-60 in accordance with Annex 1, Part 3 of the IMO 2010 FTP Code.
source: uscg-cgmix
model_number: 164.136/112/0
⚙️
"LMD-H1-HBW" single-leaf hinged fire door with optional window tested and approved as Class A-60 in accordance with Annex 1, Part 3 of the IMO 2010 FTP Code.
source: uscg-cgmix
model_number: 164.136/115/0
⚙️
"LMD-HD-ROH" double-leaf hinged fire door with optional hose port approved as Class A-60 in accordance with Annex 1, Part 3 of the IMO 2010 FTP Code.
source: uscg-cgmix
model_number: 164.136/127/0
⚙️
"LMD-HS-NR-30" single-leaf hinged fire door with optional window and hose port approved as Class A-30 in accordance with Annex 1, Part 3 of the IMO 2010 FTP Code.
source: uscg-cgmix
model_number: 164.136/128/0
⚙️
"LMD-HSL-1" single-leaf hinged fire door approved as Class A-60 in accordance with Annex 1, Part 3 of the IMO 2010 FTP Code.
source: uscg-cgmix
model_number: 164.136/129/0
🏭
Wuxi MNET Equipment Tech
22⚙️
Class A-60 Fire Door, Type 262WHL005X-00
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008K6
⚙️
Class A-0 Fire Door, Type 262WHL016X-00
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008K5
⚙️
Certificate MEDD000029S
imo_approved: True
source: dnv-approval-finder
model_number: MEDD000029S
⚙️
A60 Class Electric Sliding Fire door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000805
⚙️
Control system of A60 Class electric sliding fire door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000806
⚙️
Class A-0 Fire Rectangular Window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007SS
⚙️
Class A-60 Fire Fixed Rectangular Window ( 2 Vertical Girder) (261WDL007-00)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007SV
⚙️
A60 single-leaf fire door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007S4
⚙️
A-0 Class Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007SC
⚙️
262WDL090-00 Type Class A-60 Pneumatic Fire Sliding Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007SK
⚙️
Class A-60 Pneumatic Fire Sliding Door Control Device
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007SM
⚙️
Class A-60 Fixed Fire Rectangular Window 261WDL001-00
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007SY
⚙️
A-60 Single-Leaf Fire Door, Type 262WHL653C-00
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007S7
⚙️
Class B-15 Panel Installed Fire Door (262WHL006S-00)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007SA
⚙️
Class A-0 Fire Fixed Rectangular Window (One Vertical Girder) (261WDL003-00)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007T1
⚙️
Class A-0 Fire Fixed Rectangular Window (261WDL004-00)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007SZ
⚙️
262WDL022-00 Type Class A-60 Double-leaf Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007SG
⚙️
Class A-60 Fire Fixed Round Window (261WDL008-00)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007T5
⚙️
A-60 DOUBLE OPENED FIRE DOOR
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007S3
⚙️
A-60 FIRE DOOR
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007S2
⚙️
A-60 Double-Leaf Fire Door, Type 262WHL651C-00
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007S8
⚙️
A60 Fireproof Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007S9
🏭
Huanan Building Materials (Shenzhen)
21⚙️
Fire Resisting Ceiling Panel - Type "T25DXY" (T25DXY')
source: uk-mca
model_number: LR23100952UKMB
⚙️
Fire Resisting Single Leaf Hinged Door - Type: 'Marine MB15FD(II)" ('Marine MB15FD(II)")
source: uk-mca
model_number: LR23101513UKMB
⚙️
Fire Resisting 'B; Class Bulkhead Panel System-Type "B30A" (B30A)
source: uk-mca
model_number: LR23101626UKMB
⚙️
Fire Resisting Double Leaf Hinged Door - Type "SZMA60CX" (SZMA60CX)
source: uk-mca
model_number: LR23101696UKMB
⚙️
Fire Resisting Single Leaf Hinged Door - Type: 'Marine ZMA15CX" ('Marine ZMA15CX")
source: uk-mca
model_number: LR23101761UKMB
⚙️
Fire Resisting Single Leaf Hinged Door - Type: 'Marine ZMB15CXT(I)" ('Marine ZMB15CXT(I)")
source: uk-mca
model_number: LR23101900UKMB
⚙️
Fire Resisting Single Leaf Hinged Door - Type: 'MKB15CXT" ('MKB15CXT")
source: uk-mca
model_number: LR23101950UKMB
⚙️
Fire Resisting Single Leaf Hinged Door - Type: 'BJMB15(V)" ('BJMB15(V)")
source: uk-mca
model_number: LR23101983UKMB
⚙️
Fire Resisting Ceiling Panel - Type "T30A" (T30A')
source: uk-mca
model_number: LR23109150UKMB
⚙️
Fire Resisting 'B' Class Bulkhead Panel System-Type "B50A" (B50A)
source: uk-mca
model_number: LR23110869UKMB
⚙️
Fire Resisting Double Leaf Hinged Door - Type "SMKB15CXT" (SMKB15CXT)
source: uk-mca
model_number: LR23111098UKMB
⚙️
Fire Resisting Single Leaf Hinged Door - Type: 'Marine ZMA60CX" ('Marine ZMA60CX")
source: uk-mca
model_number: LR23111996UKMB
⚙️
Fire Resisting Lining-Type "B25A" (B25A')
source: uk-mca
model_number: LR23112097UKMB
⚙️
Fire Resisting Ceiling Panel - Type "TJMB15" (TJMB15')
source: uk-mca
model_number: LR2397032UKMB
⚙️
A' & 'B' Class Divisions Fire Integrity: 'B' Class Divisions,B-0 Ceiling Panel, Fire Resisting Ceiling Panel – Type: “T25A” (‘T25A’)
source: uk-mca
model_number: LR2399594UKMB
⚙️
Fire Resisting Ceiling Panel System - Type "T30A(II)XY" (T30A(II)XY)
source: uk-mca
model_number: LR2412577UKMB
⚙️
Fire Resisting Class Bulkhead Panel System-Type "B50AGa" ("B50AGa")
source: uk-mca
model_number: LR24125872UKMB
⚙️
Fire Resisting 'B' Class Service Door - Type "BJMB15(II)" (BJMB15(II))
source: uk-mca
model_number: LR24125874UKMB
⚙️
Fire Resisting Single Leaf Hinged Door - Type: 'MB15TFD(I)" ('MB15TFD(I)")
source: uk-mca
model_number: LR24125876UKMB
⚙️
FIRE DOORS (“T30A(II)XY” B-0 Ceiling)
source: uk-mca
model_number: LR24125877UKMB
⚙️
Fire Resisting Class Bulkhead Panel System-Type "B25AXY" (B25AXY)
source: uk-mca
model_number: LR24125878UKMB
🏭
Wuxi Dongzhou Marine Equipment
18⚙️
class A-60 Fire Side Scuttle
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006Y2
⚙️
Class A-60 Fire Rectangular Window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006VX
⚙️
WDF-C29 Type Class A-60 Soundproof Electrical Heated Fire Window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006XX
⚙️
WDF-C27 Type Class A-60 Soundproof Fire Side Scuttle
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006XY
⚙️
WDF-C31 Fire glass A-60 rectangular window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004KZ
⚙️
WDF-C9 Type class A-0 fire rectangular window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008AB
⚙️
WDF-M22 Type Class A-60 Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004G9
⚙️
WDF-M21 Type Class A-60 Double-leaved Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004GA
⚙️
WDF-M19 Type Class A-60 Gastight and Watertight Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00003MX
⚙️
WDF-M16 Type Class A-60 Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00002GH
⚙️
WDF-M15 Type Class A-0 Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00002GG
⚙️
WDF-M17 Type Class A-60 Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00002MT
⚙️
WDF-C38 Class A-0 Fire Rectangular Window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007ZX
⚙️
Certificate MEDD00000KA
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00000KA
⚙️
WDF-C35 Type Class A-60 Fire Rectangular Window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007ZU
⚙️
WDF-C39 Type Class A-0 Fire Round Window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007ZY
⚙️
WDF-C37 Type Class A-60 Fire Rectangular Window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007ZW
⚙️
WDF-C36 Type class A-0 Fire Rectangular Window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007ZV
🏭
NORAC
16⚙️
B-15 Class Single Leaf Hinged Fire Door, type "N-MC door"
source: uk-mca
model_number: 74123/A0 UK
⚙️
A-60 Class Light Weight Bulkhead, type "CIS-100"
source: uk-mca
model_number: 74125/A0 UK
⚙️
B-15 Class Single Leaf Hinged Fire Door, type "N-ML Door"
source: uk-mca
model_number: 74126/A0 UK
⚙️
A-30 Class Single Leaf Hinged Fire Door, type "N-HD A30 Door"
source: uk-mca
model_number: 74127/A0 UK
⚙️
A-60 Class Double Leaf Hinged Fire Door, type "N-HD A60 Double Door"
source: uk-mca
model_number: 74128/A0 UK
⚙️
A-60 Class Single Leaf Hinged Fire Door, type "N-HD A60 Door"
source: uk-mca
model_number: 74129/A0 UK
⚙️
B-15 Class Double Leaf Hinged Fire door, type "N-ML Double Door"
source: uk-mca
model_number: 74130/A0 UK
⚙️
B-15 Class Self-Suspended Ceiling / A-30 Class Deck, type "B-600/40"
source: uk-mca
model_number: 80179/A0 UK
⚙️
B-15 Class Bulkhead, type "K-600 panel system"
source: uk-mca
model_number: 80180/A0 UK
⚙️
B-15 Class NORAC WET UNIT
source: uk-mca
model_number: 80181/A0 UK
⚙️
B-15 Class Bulkhead, type "K-600/25 / B-15 Class Bulkhead, type "A-585/25
source: uk-mca
model_number: 80182/A0 UK
⚙️
B-15 Class Single Leaf Sliding Fire Door, type "N-SD"
source: uk-mca
model_number: 80183/A0 UK
⚙️
B-15 Class Single Leaf Hinged Steel Door, type "N-MB"
source: uk-mca
model_number: 80184/A0 UK
⚙️
A-60 Class Light Weight Bulkhead, type "CIS-100" or "CIS-100A"
source: uk-mca
model_number: 80185/A0 UK
⚙️
B-15 Class Single Leaf Hinged Steel Fire Door, type "N-CD-II" with optional accessories
source: uk-mca
model_number: 80186/A0 UK
⚙️
B-15 Class Bulkhead, type "Q-600/50 wall panel system" / B-15 Class Bulkhead, type "Q-600/70 wall panel system"
source: uk-mca
model_number: 80187/A0 UK
🏭
Apollo Fire Detectors
14⚙️
45681-394
source: uk-mca
model_number: 8504-UKCA-MCA-UKCMA10009
⚙️
55000-440 Class A2S Heat Detector
source: uk-mca
model_number: 8504-UKCA-MCA-UKCMC10032
⚙️
58000-600MAR Optical Smoke Detector
source: uk-mca
model_number: 8504-UKCA-MCA-UKCMC10033
⚙️
58100-970MAR Red Manual Call Point
source: uk-mca
model_number: 8504-UKCA-MCA-UKCMC10034
⚙️
Orbis Conventional Range of Heat Detectors
source: uk-mca
model_number: 8504-UKCA-MCA-UKCMC10035
⚙️
Orbis Conventional Range of Smoke Detectors
source: uk-mca
model_number: 8504-UKCA-MCA-UKCMC10036
⚙️
55000-026-MAR UV Flame Detector
source: uk-mca
model_number: 8504-UKCA-MCA-UKCMC10037
⚙️
Orbis IS Conventional Range Heat Detectors
source: uk-mca
model_number: 8504-UKCA-MCA-UKCMC10038
⚙️
Orbis IS Conventional Range Smoke Detectors
source: uk-mca
model_number: 8504-UKCA-MCA-UKCMC10039
⚙️
55000-772MAR DIN Rail switch monitor plus
source: uk-mca
model_number: 8504-UKCA-MCA-UKCMC10040
⚙️
55000-640 XP95 I.S. Optical Smoke Detector
source: uk-mca
model_number: 8504-UKCA-MCA-UKCMC10042
⚙️
58200-975, 58200-976
source: uk-mca
model_number: 8504-UKCA-MCA-UKCMC10043
⚙️
55000-773 Zone Monitor with Isolator
source: uk-mca
model_number: 8504-UKCA-MCA-UKCMC10044
⚙️
45681-286MAR 20D Negative isolating base
source: uk-mca
model_number: 8504-UKCA-MCA-UKCMC10045
🏭
International Paint
14⚙️
Interprime 234 / Interlac 665
source: uk-mca
model_number: WCL1121/MER0026QARev.1
⚙️
Interplate 997/ Intertuf 262 / Interlac 537V
source: uk-mca
model_number: WCL1121/MER0343QARev.1
⚙️
Interplate 997/Intershield 300V/Interlac 537V
source: uk-mca
model_number: WCL1121/MER0603QARev.1
⚙️
Interplate 997/Intershield 300V/Interlac 537
source: uk-mca
model_number: WCL1121/MER0604QARev.1
⚙️
Interplate 997/Intergard 7500
source: uk-mca
model_number: WCL1121/MER0605QARev.1
⚙️
Interplate 997/Intershield 300V/Intergard 5377
source: uk-mca
model_number: WCL1121/MER0606QARev.1
⚙️
Intergard 7500/Interlac 537V
source: uk-mca
model_number: WCL1121/MER0607QARev.1
⚙️
Intertuf 262/Interlac 665
source: uk-mca
model_number: WCL1121/MER0608QARev.1
⚙️
Intertuf 262
source: uk-mca
model_number: WCL1121/MER0609QARev.1
⚙️
Interthane 990 Finish System
source: uk-mca
model_number: WCL1121/MER1038QARev.1
⚙️
Interplate 997/Intershield 300V/Intershield 300V
source: uk-mca
model_number: WCL1121/MER1039QARev.1
⚙️
Chartek 8E - Jet fire
source: dnv-approval-finder
model_number: TAF0000022
⚙️
Chartek Fire Protective System for GRE Pipes
source: dnv-approval-finder
model_number: TAK000027C
⚙️
Chartek 7E - Jet fire
source: dnv-approval-finder
model_number: TAF0000083
🏭
UNIFRAX
14⚙️
Insulfrax blanket / Insulfrax S blanket / Insulfrax SF blanket / Insulfrax SF2 blanket / Insulfrax SFR blanket / Insulfrax SFR2 blanket
source: uk-mca
model_number: 74117/A0 UK
⚙️
Insulfrax Board 110LD
source: uk-mca
model_number: 74118/A0 UK
⚙️
FyreWrap WR Blanket / (nominal density 64~160 kg/m³)
source: uk-mca
model_number: 74119/A0 UK
⚙️
FYREWRAP LT WR Blanket / (nominal density 64~128 kg/m³)
source: uk-mca
model_number: 74121/A0 UK
⚙️
FyreWrap LT/LTF/LTF2/LTFR/LTFR2/LTG/LTG2/LTGi blankets / Insulfrax LTX/LTXF/LTXF2/LTXFR/LTXFR2/LTXG/LTXG2/LTXGi blankets
source: uk-mca
model_number: 76705/A0 UK
⚙️
Insulfrax Paper
source: uk-mca
model_number: 77661/A0 UK
⚙️
Fire Resisting ‘A’ Class Aluminium Deck – Type: “A60 Aluminium Deck FyreWrap
LT Blanket 70” 4mm thick aluminium deck insulated underside with Alkaline
Earth Silicate (AES) wool insulation (55mm thick and 70kg/m3
density) (“Fire Resisting A60 Aluminium Deck FyreWrap LT Blanket 70”)
source: uk-mca
model_number: LR2532933UKMB
⚙️
Fire Resisting ‘A’ Class Deck – Type: “FyreWrap LT Blanket insulated Aluminium Deck” for Restricted Applications with Insulation on Fire hazard Side ("Fire Resisting Deck 60 FyreWrap LT Blanket")
source: uk-mca
model_number: LR2533422UKMB
⚙️
Fire Resisting Aluminium Deck Insulated on the underside with Type: “FireResisting Deck 60”system for High-Speed Craft, using “FyreWrap LT” AES wool insulation (Fire-Resisting Deck 60 - FyreWrap LT (Marine) Blanket)
source: uk-mca
model_number: LR2533579UKMB
⚙️
Fire Resisting ‘A’ Class Bulkhead – Type: “FyreWrap LT Blanket insulated Aluminium Bulkhead” for Restricted Applications with Insulation on Fire hazard Side (Fire Resisting Bulkhead 60 - FyreWrap LT Blanket)
source: uk-mca
model_number: LR2533610UKMB
⚙️
Fire Resisting ‘A’ Class Bulkhead – Type: “FyreWrap LT Blanket insulated Aluminium Bulkhead” (Fire Resisting Bulkhead 60 - FyreWrap LT Blanket)
source: uk-mca
model_number: LR2533618UKMB
⚙️
Fire Resisting ‘A’ Class Aluminium Bulkhead – Type: “A60 Aluminium Bulkhead FyreWrap LT Blanket 70” 4mm thick aluminium bulkhead insulated on both side with Alkaline Earth Silicate (AES) wool insulation (55mm thick and 70kg/m3 density) (Fire Resisting Bulkhead 60 - FyreWrap LT Blanket 70)
source: uk-mca
model_number: LR2534658UKMB
⚙️
Fire Resisting Load Bearing Aluminium Bulkhead Insulated on the Stiffened Face (Fire Hazard Side) with Type “Load Bearing Fire-Resisting Bulkhead 60” system for High-Speed Craft, using “FyreWrap LT” AES wool Insulation” (Load Bearing Fire-Resisting Bulkhead 60 - FyreWrap LT (Marine) Blanket)
source: uk-mca
model_number: LR2534686UKMB
⚙️
FyreWrap Blanket FyreWrap SF Blanket FyreWrap SF2 Blanket FyreWrap SFR Blanket FyreWrap SFR2 Blanket
source: uk-mca
model_number: SMS.UK.D/48332/A.0
🏭
CHUGOKU MARINE PAINTS
12⚙️
Modified Epoxy Coating and Alkyd Resin Coating System
source: uk-mca
model_number: 74009/A0 UK
⚙️
Pure Epoxy Coating and Alkyd Resin Coating System
source: uk-mca
model_number: 74156/A0 UK
⚙️
Floor covering "MAXSTOP GS and MAXSTOP GR"
source: uk-mca
model_number: 74404/A0 UK
⚙️
Pure Silicone Coating System
source: uk-mca
model_number: 74405/A0 UK
⚙️
High Build Water Based Coating System
source: uk-mca
model_number: 74406/A0 UK
⚙️
Inorganic Coating
source: uk-mca
model_number: 74407/A0 UK
⚙️
Pure Epoxy Coating System
source: uk-mca
model_number: 74408/A0 UK
⚙️
Alkyd Resin Coating System
source: uk-mca
model_number: 74554/A1 UK
⚙️
Modified Epoxy Coating System
source: uk-mca
model_number: 74555/A1 UK
⚙️
Alkyd Resin Coating and High Build Water Based Coating System
source: uk-mca
model_number: 74556/A0 UK
⚙️
Modified Epoxy Coating and High Build Water Based Coating System
source: uk-mca
model_number: 74558/A0 UK
⚙️
Pure Epoxy Coating and Urethane Coating System
source: uk-mca
model_number: 74559/A0 UK
🏭
Vescom
12⚙️
Upholstery: 80%-91% Wool / 9%-20% PA _ 309g/m²-457g/m² (Lindau, Bowen, Balta, Lani)
source: uk-mca
model_number: UK_2023_0022_B
⚙️
Adhesive Vescom 1000, Vescom 2000, Vescom 2500, Vescom 3000 on metal sheet
source: uk-mca
model_number: UK_2023_0045_B
⚙️
Decorative wallcovering made of a non-woven cellulose/polyester and a 100% silk finish _
200-230g/m² _ 0.4mm (Vescom Silk Wallcovering)
source: uk-mca
model_number: UK_2023_0058_B
⚙️
Decorative wallcovering made of a cotton fabric backing and a vinyl topcoat or made of a nonwoven Cutron backing and a digital printed vinyl film _ 350g/m² _ 0.4mm (Vescom Vinyl Wallcovering)
source: uk-mca
model_number: UK_2023_0059_B
⚙️
Upholstery _ 100% PES-FR _ 360 g/m²-607 g/m² (Ponza, Namal)
source: uk-mca
model_number: UK_2023_0068_B
⚙️
Draperies, curtains _ 100% PES FR/100% PES+floc _ 250 g/m²- 571 g/m² (Bedra, Bedra + print, Nila + print, Bray + print, Dabie + print, Moroni + print, Moroni, Tavira, Iseo, Ponza, Pollux)
source: uk-mca
model_number: UK_2023_0069_D
⚙️
Draperies, curtains _ 100% PES-FR _ 23 g/m²-297 g/m² (Fogo, Coron, Dolin, Farasan, Chira, Arkoi, Flint, Faray, Fara, Etolin, Erwa, Eden, Dinas, Delos, Cedros, Burano, York, Syrna, Sindo, Salina, Romo, Nora, Nelson, Naltar, Morgan, Mioko, Mindoro, Long, Lavan, Flores, Ombo, Tilos, Clare, Syros, Liran, Swan, Tula, Ellis, Rona, Mask, Town, Teon, Toby)
source: uk-mca
model_number: UK_2023_0084_D
⚙️
Upholstery: 75% Wool / 20%-25% PES / 0%-5% PA _ 425g/m²-438g/m² (Wolin, Lamu)
source: uk-mca
model_number: UK_2024_0029_B
⚙️
Upholstery _46%-65% mohair + 35%-54% cotton / 70% mohair + 30% silk _ 546-843 g/m² (Zanzibar, Ariana, Togo, Monte)
source: uk-mca
model_number: UK_2024_0077_B
⚙️
Upholstery _100% PES-FR with at least 50% recycled content _ 420-738 g/m² (Norfolk, Wilson, Heyburn, Harding, Avon, Foster, Auckland, Moore, Zenith, Colour Connect)
source: uk-mca
model_number: UK_2024_0078_B
⚙️
Upholstery _ 100% PES-FR _ 170 g/m²-821 g/m² (Bikar, Lombok, Nauru, Ambu, Cres, Yuma, Hainan, Honshu, Hestan, Keros, Samar, Deans, Eliot, Fuga, Travis, Davis, Burton, Noss, Acton, Rolla, Dikson)
source: uk-mca
model_number: UK_2024_0079_B
⚙️
Draperies, curtains _ 100% PES-FR _ 91 g/m²-133 g/m² (Formoza, Marmara, Carmen, Tay, Tinos, Elara)
source: uk-mca
model_number: UK_2024_0081_B
🏭
WKE-Kohlstedt Torsten Kohlstedt
12⚙️
Class A-60 fire closure
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00002R2
⚙️
Certificate MEDF00000XS
imo_approved: True
source: dnv-approval-finder
model_number: MEDF00000XS
⚙️
Certificate MEDF00000UE
imo_approved: True
source: dnv-approval-finder
model_number: MEDF00000UE
⚙️
Certificate MEDF000010G
imo_approved: True
source: dnv-approval-finder
model_number: MEDF000010G
⚙️
Certificate MEDF00000Y5
imo_approved: True
source: dnv-approval-finder
model_number: MEDF00000Y5
⚙️
Certificate MEDF000010J
imo_approved: True
source: dnv-approval-finder
model_number: MEDF000010J
⚙️
Certificate MEDF00000Y6
imo_approved: True
source: dnv-approval-finder
model_number: MEDF00000Y6
⚙️
Certificate MEDF000043W
imo_approved: True
source: dnv-approval-finder
model_number: MEDF000043W
⚙️
Certificate MEDF000043X
imo_approved: True
source: dnv-approval-finder
model_number: MEDF000043X
⚙️
Certificate MEDF000043Y
imo_approved: True
source: dnv-approval-finder
model_number: MEDF000043Y
⚙️
Certificate MEDF0000416
imo_approved: True
source: dnv-approval-finder
model_number: MEDF0000416
⚙️
Certificate MEDF000010H
imo_approved: True
source: dnv-approval-finder
model_number: MEDF000010H
🏭
F Ball &
10⚙️
Styccobond F49 Hybrid PS
source: uk-mca
model_number: 164.112\1121\WCL MER0496QA
⚙️
Stopgap 1200
source: uk-mca
model_number: WCL1121/MER0390QARev.1
⚙️
Styccobond F3
source: uk-mca
model_number: WCL1121/MER0392QARev.1
⚙️
Styccobond F40
source: uk-mca
model_number: WCL1121/MER0393QARev.1
⚙️
Styccobond F58 Plus
source: uk-mca
model_number: WCL1121/MER0394QARev.1
⚙️
Styccobond F44
source: uk-mca
model_number: WCL1121/MER0400QARev.1
⚙️
Styccobond F46
source: uk-mca
model_number: WCL1121/MER0401QARev.1
⚙️
Styccobond F81
source: uk-mca
model_number: WCL1121/MER0402QARev.1
⚙️
Stopgap1500
source: uk-mca
model_number: WCL1121/MER1034QARev.1
⚙️
Styccobond F73 Plus
source: uk-mca
model_number: WCL1121/MER1050QARev.1
🏭
NORAC Suzhou
10⚙️
WU Type Class B-15 Wet Unit
source: uk-mca
model_number: MERB00006BB-0
⚙️
B-15 Class fire door, type MCZ
source: uk-mca
model_number: MERB00006M8-0
⚙️
B-15 Class fire door, type MC
source: uk-mca
model_number: MERB00006M9-0
⚙️
B-15 Class fire door, type ML
source: uk-mca
model_number: MERB00006MA-0
⚙️
B-15 Class fire door, type MLDD
source: uk-mca
model_number: MERB00006MB-0
⚙️
A-30 Class fire door, type A30
source: uk-mca
model_number: MERB00006MC-0
⚙️
A-60 Class fire door, type A60
source: uk-mca
model_number: MERB00006MD-0
⚙️
Lining W25C15, B15 Class
source: uk-mca
model_number: MERB00006Z8-0
⚙️
Bulkhead W50C15, B15 class
source: uk-mca
model_number: MERB00006Z9-0
⚙️
W50C15H Type Class B-15 Bulkhead
source: uk-mca
model_number: MERB00006ZA-0
🏭
Jiangyin Dongrui Decoration Materials
9⚙️
B-15 Class Bulkhead ("CLP-P7" B-15 Bulkhead)
source: uk-mca
model_number: LR23373776UKMB
⚙️
B-15 Door ("CFM-7A" B-15 Door Single Leaf Hinged)
source: uk-mca
model_number: LR23373784UKMB
⚙️
B-15 Door ("CFM-3A" B-15 Door Single Leaf Hinged)
source: uk-mca
model_number: LR23373793UKMB
⚙️
B-15 Door ("CFM-AD1" B-15 Door Single Leaf Hinged)
source: uk-mca
model_number: LR23373802UKMB
⚙️
A-60 Door ("CFM-1Z" A-60 Door Single Leaf Hinged)
source: uk-mca
model_number: LR23373813UKMB
⚙️
B-15 Ceiling ("CLP-C2" B-15 Ceiling)
source: uk-mca
model_number: LR23373818UKMB
⚙️
B-15 Class Bulkhead Lining (“CLP-L3” B-15 Lining)
source: uk-mca
model_number: LR23373831UKMB
⚙️
B-15 Class Bulkhead (“CLP-P1” B-15 Bulkhead)
source: uk-mca
model_number: LR23373835UKMB
⚙️
B-0 Ceiling (“CLP-C6A” B-0 Ceiling)
source: uk-mca
model_number: LR23373838UKMB
🏭
Polyflor
9⚙️
VOYAGER MARITIME
source: uk-mca
model_number: 73896/A0 UK
⚙️
Polysafe Stud Tile (thickness 3.0 mm)
source: uk-mca
model_number: 73897/A0 UK
⚙️
Timestep
source: uk-mca
model_number: 74021/A0 UK
⚙️
POLYFLOR 2000 PUR / PRIMUS 2000 PUR
source: uk-mca
model_number: 74105/A0 UK
⚙️
POLYFLOR XLPU / POLYFLOR ULTRA XLPUR
source: uk-mca
model_number: 74106/A0 UK
⚙️
VOYAGER XL
source: uk-mca
model_number: 74107/A0 UK
⚙️
VOYAGER PUR
source: uk-mca
model_number: 74108/A0 UK
⚙️
POLYFLOR STANDARD XL / ROBUST XL
source: uk-mca
model_number: 74109/A0 UK
⚙️
VOYAGER PU
source: uk-mca
model_number: 74110/A0 UK
🏭
Rockwool Danmark
9⚙️
Steel Deck A60, floating floor
source: uk-mca
model_number: MERB000016G-0
⚙️
Steel Deck A60 with SeaRox SL 620 - type 2
source: uk-mca
model_number: MERB00002EB-0
⚙️
A-30 Deck, Steel with SeaRox SL 620
source: uk-mca
model_number: MERB00002HA-0
⚙️
A-30 Bulkhead, Steel with SeaRox SL 620
source: uk-mca
model_number: MERB00002HC-0
⚙️
Aluminium Bulkhead A60 with SeaRox FM 6040 ALU
source: uk-mca
model_number: MERB00002RZ-0
⚙️
Aluminium Bulkhead A60 Restricted with SeaRox FM 6040 ALU
source: uk-mca
model_number: MERB00002S3-0
⚙️
Aluminium Deck A60 with SeaRox FM 6040 ALU
source: uk-mca
model_number: MERB00003AH-0
⚙️
Class A-60 Aluminium Bulkhead with 'SeaRox FB 6050' or 'SeaRox FM 6050'
source: uk-mca
model_number: MERB00007Z4-0
⚙️
Class A-60 Aluminium Deck with 'SeaRox FB 6050' or 'SeaRox FM 6050'
source: uk-mca
model_number: MERB00007Z7-0
🏭
China Marine Windows Shipyard
8⚙️
Certificate MEDD000001K
imo_approved: True
source: dnv-approval-finder
model_number: MEDD000001K
⚙️
CMWS-WTFD-9017-A60 Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000008C
⚙️
CMWS-FWTD-A0 Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000915
⚙️
CMWS-AWTD-A60 Fire Door (ALuminium Alloy)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008HA
⚙️
CMWS-A0 Fire Window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008H8
⚙️
CMWS-A60 Fire Window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008H9
⚙️
CMWS-A-60 Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004AC
⚙️
CMWS-A-0 Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004EB
🏭
Jiangyin Haisheng Marine Outfitting & Decoration
8⚙️
HS-M12 Type Class A-60 Double-leaf Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000065A
⚙️
HS-M11 Type Class A-60 Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000659
⚙️
Type Class A-60 Door Double-leaf Fire Door/HS-M8
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00005X2
⚙️
Type Class A-0 Fire Door/HS-M4
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00005X5
⚙️
HS-FM2 Type Class A-60 Double-Leaf Fire Door (with observation window)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000093F
⚙️
HS-FM1 Type Class A-60 Fire Door (with observation window)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000093E
⚙️
HS-M10 Type Class B-15 Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000657
⚙️
Type Class B-0 Fire Door/HS-M5
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00005X3
🏭
NAVALIBER
8⚙️
B-15 Class Bulkheads - Type "ISOLIBER 3B-15 ACUSTIC"
source: uk-mca
model_number: 75822/A0 UK
⚙️
B-15 Class Ceiling / A-30 Class Deck - Type "Self-Supporting Ceiling Navaliber B15 Class"
source: uk-mca
model_number: 75823/A0 UK
⚙️
A-15 Class Single Leaf Hinged Fire Door, type "Navaliber NA-15 Door"
source: uk-mca
model_number: 75825/A0 UK
⚙️
A-60 Class Single Leaf Hinged Fire Doors - Type "NA-60"
source: uk-mca
model_number: 75826/A0 UK
⚙️
A-30 Class Single Leaf Hinged Fire Door - type "NA-30"
source: uk-mca
model_number: 75827/A0 UK
⚙️
A-60 Class Double Leaf Hinged Fire Doors - Type "NA-60D"
source: uk-mca
model_number: 75828/A0 UK
⚙️
B-15 Class Double Leaf Hinged Fire Door - Type "NB-15D"
source: uk-mca
model_number: 75829/A0 UK
⚙️
B-15 Class Lining Panels - Type "25B-15.2"
source: uk-mca
model_number: 75830/A0 UK
🏭
Thermal Ceramics UK
8⚙️
A-60 Steel Bulkhead (Fire Insulated Side) - FireMaster Marine Plus Blanket 50 mm x 48 kg/m3
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000045B
⚙️
A-60 Steel Bulkhead (Fire Either Side) - FireMaster Marine Plus Blanket 80 mm x 48 kg/m3
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00003YB
⚙️
A-60 Corrugated Fire Wall
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00003YD
⚙️
A-15 Steel Bulkhead (Fire Either Side) - FireMaster Marine Plus Blanket 25 mm x 64 kg/m3
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000045C
⚙️
Fire Restricting Composite Bulkheads and Decks
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000045D
⚙️
H-60/H-120 Corrugated Steel Fire Wall - fire towards either side
source: dnv-approval-finder
model_number: TAF00000VG
⚙️
H-60 Steel Bulkhead Fire Either Side – 130 mm FireMaster Marine Plus Blanket
source: dnv-approval-finder
model_number: TAF00000VE
⚙️
A-60 Aluminium Deck - 50 mm FireMaster Marine Plus Blanket
source: uk-mca
model_number: MERB00001W2-0
🏭
Tyco Fire & Security
8⚙️
P80AIB-M
source: uk-mca
model_number: 0832-UKCA-MED-F1000
⚙️
P80SW-M
source: uk-mca
model_number: 0832-UKCA-MED-F1001
⚙️
P85AIR-M
source: uk-mca
model_number: 0832-UKCA-MED-F1002
⚙️
711PH
source: uk-mca
model_number: 0832-UKCA-MED-F1003
⚙️
711P
source: uk-mca
model_number: 0832-UKCA-MED-F1004
⚙️
711H, 712H, 713H
source: uk-mca
model_number: 0832-UKCA-MED-F1005
⚙️
80DSB-M
source: uk-mca
model_number: 0832-UKCA-MED-F1006
⚙️
P80AIB-M, P80SW-M, P85AIR-M, 711PH, 711P, 711H, 712H, 713H, 80DSB-M, P80SB-M
source: uk-mca
model_number: 0832-UKCA-MED-F1007
🏭
Antti-Teollisuus
7⚙️
AM B-15 Fire Door dB(DL)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000144
⚙️
B-15 Fire Door dB(LE+) Single Leaf
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000071A
⚙️
AM B-15 Fire Door (LU) Double leaf
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000B1A
⚙️
AM B-15 Fire Door (LU) Single Leaf
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00009DD
⚙️
AM B-15 Fire Door dB (LRU) Single Leaf
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00009DE
⚙️
Certificate MEDD00002H8
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00002H8
⚙️
B-15 Fire Door dB(L+) Single leaf
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000216
🏭
Autronica Fire and Security
7⚙️
Interactive fire panels
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00003UH
⚙️
Interactive fire detectors
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006DJ
⚙️
Interactive fire detectors BG-21, BG-201, BG-301, BG-301-EXIA, BG-301-EXIC
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006DK
⚙️
Interactive Fire Detectors
source: dnv-approval-finder
model_number: MERB0001N6D
⚙️
Autroprime BS-200M Interactive Fire Alarm System.
source: uscg-cgmix
model_number: 161.002/51/0
⚙️
AutroSafe4 Interactive Fire Alarm System.
source: uscg-cgmix
model_number: 161.002/57/0
⚙️
AutroGuard V-430 and V-530 series and AutroGuard Retro, combined smoke and heat detectors with base, approved as combination heat detector and smoke detector for use in Category 1, 2, and 3 spaces.
source: uscg-cgmix
model_number: 161.002/70/0
🏭
Kidde-Fenwal
7⚙️
Novec 1230 /Fluoro-K ECS 360 psi
source: uk-mca
model_number: MERB00002NN-1
⚙️
High Pressure Marine Carbon Dioxide Fire Extinguishing Systems.
source: uscg-cgmix
model_number: 162.038/1/0
⚙️
HFC-227 ECS Total Flooding Clean Agent System.
source: uscg-cgmix
model_number: 162.161/1/0
⚙️
HFC-227 ADS Total Flooding Clean Agent System.
source: uscg-cgmix
model_number: 162.161/7/0
⚙️
NOVEC 1230 and Fluoro-K (FK-5-1-12) Total Flooding Clean Agent System.
source: uscg-cgmix
model_number: 162.161/9/0
⚙️
NOVEC 1230 and Fluoro-K (FK-5-1-12) ADS Total Flooding Clean Agent System.
source: uscg-cgmix
model_number: 162.161/14/0
⚙️
ECS-500 PSI NOVEC 1230 and Fluoro-K (FK-5-1-12) Total Flooding Fire Suppression System.
source: uscg-cgmix
model_number: 162.161/15/0
🏭
Muraspec Decorative Solutions
7⚙️
Wallcovering "CELESTE"
source: uk-mca
model_number: 74157/A0 UK
⚙️
Wallcovering MURABASE 'NW'
source: uk-mca
model_number: 74158/A0 UK
⚙️
Wallcovering "FABRIC BACKED VINYL (FBV) 350-455 gsm (NON WOVEN)"
source: uk-mca
model_number: 74159/A0 UK
⚙️
Wallcovering "FBV Type II (Non Woven)"
source: uk-mca
model_number: 74160/A0 UK
⚙️
Wallcovering "FBV Type II (Woven)"
source: uk-mca
model_number: 74161/A0 UK
⚙️
Wallcovering "FABRIC BACKED VINYL (FBV) 360 gsm (WOVEN)"
source: uk-mca
model_number: 74162/A0 UK
⚙️
Heavy Duty Wallcovering Platinum
source: uk-mca
model_number: SMS.UK.D/3035/B.0
🏭
Pesbo
7⚙️
BSC-30 MCI, equipped with water spray fire-protection system
(Construction No.: 2619)
imo_approved: True
source: dnv-approval-finder
model_number: 1559900 Lux
⚙️
BSC-30 MCI, equipped with water spray fire-protection system
(Construction No.: 2620)
imo_approved: True
source: dnv-approval-finder
model_number: 1560000 Lux
⚙️
BSC-30 MCI, equipped with water spray fire-protection system
(Construction No.: 2622)
imo_approved: True
source: dnv-approval-finder
model_number: 1560200 Lux
⚙️
BSC-30 MCI, equipped with water spray fire-protection system (Construction No.: 2616)
imo_approved: True
source: dnv-approval-finder
model_number: 1547300 Lux
⚙️
BSC-30 MCI, equipped with water spray fire-protection system (Construction No.: 2615)
imo_approved: True
source: dnv-approval-finder
model_number: 1547200 Lux
⚙️
BSC-30 MCI, equipped with water spray fire-protection system
(Construction No.: 2621)
imo_approved: True
source: dnv-approval-finder
model_number: 1560100 Lux
⚙️
BSC-30 MCI, equipped with water spray fire-protection system (Construction No.: 2614)
imo_approved: True
source: dnv-approval-finder
model_number: 1547100 Lux
🏭
SIOEN
7⚙️
Fireman jacket 830 Twin/AS in combination with fireman trousers 830 Twin/AS
source: uk-mca
model_number: UK_2022_0003_B
⚙️
Intervention garment 529 T Microrip/AS
source: uk-mca
model_number: UK_2022_0014_B
⚙️
Intervention garment 531/AS
source: uk-mca
model_number: UK_2022_0015_B
⚙️
Fire Fighter Gloves 2MZOA2VL1
source: uk-mca
model_number: UK_2022_0018_B
⚙️
Intervention garment 830 Square EV /AS (Intervention garment 830 Square EV /AS)
source: uk-mca
model_number: UK_2024_0102_B
⚙️
2MZOA2VL1 - batch 4500668160: 03/204
source: uk-mca
model_number: UK_2024_0103_F
⚙️
2MZOA2VL1 - batch 4500636502: 04/2024
source: uk-mca
model_number: UK_2024_0104_F
🏭
AdvanTec Manufacturing Canada
6⚙️
Certificate MEDD00002G7
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00002G7
⚙️
1223-A30 Fire Doors
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008T7
⚙️
1223-A15 Fire Doors
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008T9
⚙️
1223-A0 Fire Doors
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008T6
⚙️
1623-A15 Fire Doors
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008TA
⚙️
1223-A60 Fire Doors
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008T8
🏭
Draeger Safety UK
6⚙️
Saver CF
source: uk-mca
model_number: BSI/UK/3.41/756869
⚙️
Saver PP
source: uk-mca
model_number: BSI/UK/3.41/756870
⚙️
PAS Lite, PSS 3000 & PSS 4000
source: uk-mca
model_number: BSI/UK/3.7/756863
⚙️
PSS 5000
source: uk-mca
model_number: BSI/UK/3.7/756865
⚙️
PSS 7000
source: uk-mca
model_number: BSI/UK/3.7/756868
⚙️
PSS Airboss
source: uk-mca
model_number: BSI/UK/3.7/785328
🏭
Marioff
6⚙️
Hi-Fog open type spray heads. Models 4S 1MC 8MB 1000, 5S 1MC 8MB 1000, and 5S 1MC 8MC 1000.
source: uscg-cgmix
model_number: 162.135/7/0
⚙️
Marioff Hi-Fog 2000 water mist system.
source: uscg-cgmix
model_number: 162.135/9/0
⚙️
Hi-Fog MT 4 System for total flooding and local application protection.
source: uscg-cgmix
model_number: 162.135/11/0
⚙️
Marioff Hi-Fog 3000 water mist system.
source: uscg-cgmix
model_number: 162.135/18/0
⚙️
Marioff Hi-Fog water mist systems for ro-ro spaces and special category spaces.
source: uscg-cgmix
model_number: 162.135/20/0
⚙️
Marioff Hi-Fog 3000 water mist systems for ro-ro spaces and special category spaces.
source: uscg-cgmix
model_number: 162.135/21/0
🏭
NAFFCO
6⚙️
NP6 – 6kg ABC Dry Powder, Stored Pressure Fire Extinguisher. Fire ratings 34A & 183B.
NPS6 – 6kg BC Dry Powder, Stored Pressure Fire Extinguisher. Fire rating 183B.
NP9 – 9kg ABC Dry Powder, Stored Pressure Fire Extinguisher. Fire ratings 43A & 233B.
NPS9 – 9kg BC Dry Powder, Stored Pressure Fire Extinguisher. Fire rating 233B.
NP12 – 12kg ABC Dry Powder, Stored Pressure Fire Extinguisher. Fire ratings 55A & 233B.
NPS12 – 12kg BC Dry Powder, Stored Pressure Fire Extinguisher. Fire rati
source: uk-mca
model_number: BSI/UK/3.2/78427
⚙️
NP3 - 3Kg PRO FORTY 40% Dry Powder, Stored Pressure Fire Extinguisher, Fire rating, 21A & 89B
source: uk-mca
model_number: BSI/UK/3.38/736076
⚙️
NP1 – 1kg ABC Dry Powder, Stored Pressure Fire Extinguisher. Fire ratings 8A & 34B.
NP2 - 2Kg ABC Dry Powder, Stored Pressure Fire Extinguisher. Fire ratings 13A & 70B.
NP3 – 3kg ABC Dry Powder, Stored Pressure Fire Extinguisher. Fire ratings 21A & 89B.
NP4 - 4Kg ABC Dry Powder, Stored Pressure Fire Extinguisher. Fire rating 21A & 113B.
NPS4 - 4Kg BC Dry Powder, Stored Pressure Fire Extinguisher. Fire rating 113B.
NF6 – 6 Litre AFFF, Stored Pressure Fire Extinguisher. Fire ratings 21A
source: uk-mca
model_number: BSI/UK/3.38/78426
⚙️
NTP25 - 25kg 85% ABC Dry Chemical Powder Stored, Pressure Fire Extinguisher. Fire Ratings A & IIB, 25kg 40% ABC Dry Chemical PRO FORTY Powder, Stored Pressure Fire Extinguisher. Fire Ratings A & IIIB;
NTP50 - 50kg 85% ABC Dry Chemical Powder Stored, Pressure Fire Extinguisher. Fire Ratings A & IVB;
NTP100 - 100kg 85% ABC Dry Chemical Powder Stored, Pressure Fire Extinguisher. Fire Ratings A & IVB;
NTPS25 - 25kg 90% BC Dry Chemical Powder Stored. Pressure Fire Extinguisher. Fire Rati
source: uk-mca
model_number: BSI/UK/3.52/736118
⚙️
NTFC50X - 50 Litre AFFF 6% Foam Fire Extinguisher with external Co2 Cartridge, Fire Rating A & IVB;
NTFC100X - 100 Litre AFFF 6% Foam Fire Extinguisher with external Co2 Cartridge, Fire Rating A & IVB;
NTFC135X - 135 Litre AFFF 6% Foam Fire Extinguisher with external Co2 Cartridge, Fire Rating A & IVB.
source: uk-mca
model_number: BSI/UK/3.52/736119
⚙️
NTC10X - 10kg Co2 Mobile Fire Extinguisher, Fire rating 70B, NTC30X - 30kg Mobile Fire Extinguisher, Fire rating 113B
source: uk-mca
model_number: BSI/UK/3.52/736120
🏭
PAB Akrapovic d.o.o
6⚙️
Certificate MEDD00001ZX
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00001ZX
⚙️
PAB Fire Compact - ProBuddy
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000655
⚙️
PAB FIRE 05
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007XW
⚙️
Certificate MERD0001N10
source: dnv-approval-finder
model_number: MERD0001N10
⚙️
PAB Fire Compact-Probuddy
source: dnv-approval-finder
model_number: MERB0001N1E
⚙️
PAB Fire 05
source: dnv-approval-finder
model_number: MERB0001N33
🏭
Taixing City Ocean Machinery Manufacture
6⚙️
Round Fire Damper Type: CDH-Q/B/M-DN-00 (Ø1600), CDH-D/B/M-DN-00 (Ø500), CDH-S/B/S-DN-00 (Ø320)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007KG
⚙️
Round Fire Damper Type: TCDH-Q/D/M-DN-00 (Ø1600), CDH-S/D/S-DN-00 (Ø320)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007KK
⚙️
Rectangular Fire Damper Type: CDH-D/D/S-axb-00 (350 x 800)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007KJ
⚙️
Rectangular Fire Damper Type: CDH-D/B/S-axb (350 x 700), CDH-S/B/M-axb (700 x 700), CDH-Q/B/M-axb (1500 x 1500)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007KE
⚙️
Rectangular Fire Damper Type: CDH-S/B/S/S-axb (350 x 700), CDH-D/B/M/S-axb (700 x 700), CDH-Q/B/M/S-axb (1500x1500)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007KF
⚙️
Round Fire Damper Type: CDH-Q/B/M/S-DN-00 (Ø1600), CDH-D/B/M/S-DN-00 (Ø500), CDH-S/B/S/S-DN-00 (Ø320)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007KH
🏭
ALWO
5⚙️
Fire Damper type "FDA"
imo_approved: True
source: dnv-approval-finder
model_number: 5971713 HH
⚙️
Automatic fail-safe rectangular fire damper type "FDA"
imo_approved: True
source: dnv-approval-finder
model_number: 6111513 HH
⚙️
fire damper
imo_approved: True
source: dnv-approval-finder
model_number: 9474710 HH
⚙️
Automatic fail-safe rectangular fire damper, type "FDA"
imo_approved: True
source: dnv-approval-finder
model_number: 1127714 HH
⚙️
Fire damper.
imo_approved: True
source: dnv-approval-finder
model_number: 9411010 HH
🏭
Britannia Fire
5⚙️
Mobile Fire extinguishers NWC10 – NWC20 – NWC30
source: uk-mca
model_number: 23/GB-UK/1016-0-Rev.0
⚙️
Description: Portable Fire Extinguishers
P50-F2;P50–P2;P50-W2;P50-F;P50-P;P50-W;P50-F9;P50-P9;P50-F-Class;P50-UFF6
source: uk-mca
model_number: 23/GB-UK/1016-1-Rev.0
⚙️
Portable Powder, Water Based & CO2 Fire Extinguishers
source: uk-mca
model_number: 23/GB-UK/1018-0-Rev.0
⚙️
Mobile Fire extinguishers: NRA50 – NRAF45 – NRAF135 – NWM50
source: uk-mca
model_number: 23/GB-UK/1019-0-Rev.0
⚙️
Portable Fire Extinguishers
P50-F2;P50–P2;P50-W2;P50-F;P50-P;P50-W;P50-F9;P50-P9;P50-F-Class;P50-UFF6;P50-UFF9 (Britannia Fire Ltd.)
source: uk-mca
model_number: 23/GB-UK/5106-1-Rev.0
🏭
H.K. van Wingerden & Zn
5⚙️
Fire Resisting rectangular Window - Type: "Wigo Hinged A-0" (wigo Hinged A-0)
source: uk-mca
model_number: LR2435280UKMB
⚙️
Fire Resisting rectangular Window - Type: "Wigo A-0" (Wigo A-0)
source: uk-mca
model_number: LR2435281UKMB
⚙️
Fire Resisting rectangular Window - Type: "Wigo Window A-0/A-30" (Wigo Window A-0/A-30)
source: uk-mca
model_number: LR2435285UKMB
⚙️
Fire Resisting rectangular Window - Type: "Wigo Fixed Window A60" (Wigo Fixed Window A60)
source: uk-mca
model_number: LR2435286UKMB
⚙️
Fire Resisting Rectangular Window – Type: “WIGO Fixed A0 Class Window and Scuttle” (WIGO Fixed A0 Class Window and Scuttle)
source: uk-mca
model_number: LR25146804UKMD
🏭
Halton Wales (MEI)
5⚙️
Class A Fire Damper CFD-02
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004F1
⚙️
Certificate MEDD00001NK
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00001NK
⚙️
Class A Fire Damper CFD-01
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006YH
⚙️
Class H Fire Damper CFD-01
source: dnv-approval-finder
model_number: TAF00000NE
⚙️
Class H Fire Dampers CFD-01 (banked assemblies)
source: dnv-approval-finder
model_number: TAF0000065
🏭
KAEFER Schiffsausbau
5⚙️
Fire Sliding Door A-60 / FSD A-60 A3000 XV double
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008EK
⚙️
Class A-60 fire sliding door, type A 3000 Single
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004DV
⚙️
Class A-60 fire sliding door, type A 3000 Double
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004G4
⚙️
Fire Stacking Barrier A-60 for closure of Class A-60 bulkhead (unrestricted use)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00002EW
⚙️
Roller shutter for closure of Class A-0 bulkhead - Fire Roller Shutter A-0 SlimLine
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000014M
🏭
Mattison Contract Beds
5⚙️
Cosmopolitan T1147
source: uk-mca
model_number: 164.142\1121\WCL MER0457QA
⚙️
Cruiseship T1119
source: uk-mca
model_number: 164.142\1121\WCL MER0458QA
⚙️
Foam IMO In T820
source: uk-mca
model_number: 164.142\1121\WCL MER0460QA
⚙️
IMO Milan In T820
source: uk-mca
model_number: 164.142\1121\WCL MER0461QA
⚙️
Wheelmark Foam 1119 1936, T1119 / Wheelmark Foam Nautilus T820
source: uk-mca
model_number: WCL1121/ MER0357QARev.1
🏭
MML Marine
5⚙️
Fire Resisting 'A; Class Rectangular Window ("MML A60 Window")
source: uk-mca
model_number: LR22485059UKMB
⚙️
Fire Resisting Fire Door Type: "A60 Door Single Leaf Hinged" (A60 Door Single Leaf Hinged)
source: uk-mca
model_number: LR23381518UKMB
⚙️
Fire Resisting Single Leaf Hinged Door - Type "MML Marine Single Leaf Hinged Door" (MML Fire Resisting Single Leaf Hinged Door)
source: uk-mca
model_number: LR2485231UKMB
⚙️
Fire Resisting Single Leaf Hinged Door – Type: “MML Marine A15 Hinged Door" (MML Marine A15 Hinged Door)
source: uk-mca
model_number: LR2522160UKMB
⚙️
Fire Resisting Single Leaf Hinged Door – Type: “MML Marine B15 Hinged Door” (MML Marine B15 Hinged Door)
source: uk-mca
model_number: LR2522184UKMB
🏭
Mobiak S.A.-PC
5⚙️
MBK13-050CA-BSI & MBK13-050-CA1-BSI – 5kg Co2 Fire Extinguisher.
source: uk-mca
model_number: BSI/UK/3.2/609219
⚙️
MBK13-060AF-BSI – 6 Litre AFFF 3% Foam Fire Extinguisher.
source: uk-mca
model_number: BSI/UK/3.2/609220
⚙️
MBK13-060PA-BSI - 6kg ABC 40% Dry Powder, Stored Pressure, Fire Extinguisher;
MBK13-060CARTRIDGE-BSI - 6kg ABC 40% Dry Powder, Internal Cartridge, Fire Extinguisher;
MBK13-090PA-BSI - 9kg ABC 40% Dry Powder, Stored Pressure, Fire Extinguisher:
MBK13-120PA-BSI - 12kg ABC 40% Dry Powder, Stored Pressure, Fire Extinguisher.
source: uk-mca
model_number: BSI/UK/3.2/609222
⚙️
MBK13-020CA-BSI & MBK13-020-CA1-BSI – 2kg CO2 Fire Extinguisher.
source: uk-mca
model_number: BSI/UK/3.38/609217
⚙️
MBK13-020PA-BSI – 2kg ABC 40% Dry Powder Fire Extinguisher.
source: uk-mca
model_number: BSI/UK/3.38/609218
🏭
Presto
5⚙️
Certificate MEDD00001RN
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00001RN
⚙️
Presto Fire Extinguishers for lifeboats and rescue boats: CO2, 2 kg
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008XB
⚙️
Presto fire extinguishers: Powder, 6 – 12 kg
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008X2
⚙️
Presto fire extinguishers: CO2, 5 kg
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008X0
⚙️
Presto Fire Extinguishers for lifeboats and rescue boats
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004TU
🏭
SAINT-GOBAIN ISOVER G+H
5⚙️
Fire Resisting ‘A’ Class Aluminium Bulkhead – Restricted Application – Type “U SeaProtect 66” (“U Seaprotect 66 – A-30 4MM Aluminium Bulkhead”)
source: uk-mca
model_number: LR23161989UKMB
⚙️
Fire-Resisting Material – Type “SeaProtect Tape G120” Self-adhesive Glass Fibre Tape (SeaProtect Tape G120)
source: uk-mca
model_number: LR23372935UKMB
⚙️
Fire-Resisting Material – Type: “ ISOVER Aluminium Fibre-Glass Composite Alu1 or ALu2" (ISOVER Aluminium Fibre-Glass Composite Alu1 or Alu2)
source: uk-mca
model_number: LR23390491UKMB
⚙️
Fire Resisting "A" Class Aluminium Bulkhead Restricted — "U Sea Protect 66, 60mm + 40mm cavity + 2xU Sea Protect 66, 30mm" (A-60 Aluminium Bulkhead Restricted — "U Sea Protect")
source: uk-mca
model_number: LR24146742UKMB
⚙️
Fire Resisting "A" Class Aluminium Deck — "U Sea Protect 66, 60mm + 40mm cavity + 2 x U Sea Protect 66, 30mm" (A-60 Aluminium Deck — "U Sea Protect)
source: uk-mca
model_number: LR24147682UKMB
🏭
SURVITEC Fire Solution Poland
5⚙️
XFlow type NHP-2 and NHP-4 nozzles.
source: uscg-cgmix
model_number: 162.135/10/0
⚙️
XFlow water mist full protection system for machinery spaces of category A and cargo pump rooms for a volume up to 806 c.m
source: uk-mca
model_number: 73857/A0 UK
⚙️
SURVITEC FIRE SOLUTIONS XFLOW water mist total flooding system, for machinery spaces of category A and cargo pump rooms for a volume up to 2526 c.m.
source: uk-mca
model_number: 73858/A0 UK
⚙️
Fixed Fire Extinguishing System - Type: "NF XFlow Nozzles" for Accommodation Spaces, Service Spaces and Control Stations
source: uk-mca
model_number: 73936/A0 UK
⚙️
Water-based fixed local fire extinguishing system for category A machinery spaces - Type XFlow
source: uk-mca
model_number: SMS.UK.D/108739/A.0
🏭
Tarkett
5⚙️
Woven broadloom carpet _ Group Axminster: 80% wool – 20% polyamide, PP based weft & PES based warp, EVA latex compound with ATH, total weight: 1500 g/m² - 2290 g/m², total thickness: 9.0mm – 10.5mm (Decor A 070 070, Decor A 080 070, Decor A 090 070, Decor A 100 070, Decor B 070 070, Decor B 070 075, Decor B 070 080, Decor B 070 085, Decor B 080 070, Decor B 080 075, Decor B 080 080, Decor B 080 085, Decor B 090 070, Decor B 090 075, Decor B 090 080, Decor B 090 085, Decor B 100 070, De
source: uk-mca
model_number: UK_2023_0028_B
⚙️
Woven broadloom carpet _ Wilton: 80% wool – 20% polyamide, PP based weft & PES based warp, EVA latex compound FR treated with ATH, total weight:1540 g/m², total thickness:5.0mm (Wilton woven carpet)
source: uk-mca
model_number: UK_2023_0031_B
⚙️
Torso Marine EcoBaseTM - Tufted polyamide carpet tile floor covering for restricted applications _ 100% polyamide _ Polyolefin backing with SBR latex and polyester fleece FR treated with ATH + graphite, total weight: 4200 g/m², total thickness: 7.0mm (Torso Marine EcoBaseTM)
source: uk-mca
model_number: UK_2023_0032_B
⚙️
Tufted broadloom marine carpets - Tufted polyamide floor covering for restricted applications _ 100% polyamide _ PP woven&fleece _ latex compound FR treated with ATH, total weight: 2050 g/m² - 2400 g/m², total thickness: 6.0 mm - 7.5 mm (Torso (Marine), AirMaster® for Home (Marine), Palatino (Marine), Tide (Marine))
source: uk-mca
model_number: UK_2023_0033_B
⚙️
Woven broadloom carpet on underlay_ Group Axminster: 80% wool – 20% polyamide, PP based weft & PES based warp, EVA latex compound with ATH, total weight: 1500 g/m² - 1965 g/m², total thickness: 9.0mm – 10.5mm on underlay: Oceanbase, Fenixbase, Flamecheck (Decor A 070 070, Decor A 090 070, Decor B 090 070)
source: uk-mca
model_number: UK_2023_0034_B
🏭
Wozair
5⚙️
Bulkhead LFD type fire damper
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00005D4
⚙️
Deck MFD type fire damper
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00009C7
⚙️
Deck LFD type fire damper
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00009C5
⚙️
Bulkhead fire damper of MFD and LFD type
source: dnv-approval-finder
model_number: MERB0001N7H
⚙️
Deck fire damper of MFD and LFD type
source: dnv-approval-finder
model_number: MERB0001N40
🏭
Wuxi Xinfan Marine Equipment
5⚙️
261YF-05-05 Type Class A-60 Fire Service Window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006N6
⚙️
Class A-0 Fire Door, type: XF031-B-00
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006N3
⚙️
Class A-60 Steel Fire Door Type: XF028-A-00
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006N0
⚙️
Class A-0 Fire Rectangular Window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000223
⚙️
252Xf005M-00 Type Class A-60 Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000083E
🏭
Zhejiang Winner
5⚙️
MFZL6-4 - 6kg ABC 40% Dry Powder Fire Extinguishers with internal CO2 Gas Cartridge, Fire Rating 34A, 183B;
MFZL9-2 - 9kg ABC 40% Dry Powder Fire Extinguishers with internal CO2 Gas Cartridge, Fire Rating 43A, 183B;
MFZL12-2 - 12kg ABC 40% Dry Powder Fire Extinguishers with internal CO2 Gas Cartridge, Fire Rating 55A, 233B;
source: uk-mca
model_number: BSI/UK/3.2/654044
⚙️
MJPZ6-3 - 6 Litre AFFF 3% Foam Fire Extinguishers with internal CO2 Gas Cartridge, Fire Rating 13A, 113B;
MJPZ9-3 - 9 Litre AFFF 3% Foam Fire Extinguishers with internal CO2 Gas Cartridge, Fire Rating 21A, 183B.
source: uk-mca
model_number: BSI/UK/3.2/654046
⚙️
WN/MFTZ25 - 25kg ABC 40% Dry Powder, Stored Pressure, Mobile Fire Extinguisher, Fire Rating A, IB;
WN/MFTZ50 - 50kg ABC 40% Dry Powder, Stored Pressure, Mobile Fire Extinguisher, Fire Rating A, IIB.
source: uk-mca
model_number: BSI/UK/3.52/657109
⚙️
WN/MPTZ25 - 25 Litre AFFF 3% Foam, Stored Pressure, Mobile Fire Extinguishers, Fire Rating A, IB;
WN/MPTZ50 - 50 Litre AFFF 3% Foam, Stored Pressure, Mobile Fire Extinguishers, Fire Rating A, IIB.
source: uk-mca
model_number: BSI/UK/3.52/657111
⚙️
WN/MTT10 - 10kg CO2, Mobile Fire Extinguishers, Fire Rating 113B;
WN/MTT30 - 30kg CO2, Mobile Fire Extinguishers, Fire Rating 144B.
source: uk-mca
model_number: BSI/UK/3.52/657113
🏭
Changshu Haixin Ship Machinery Manufacture
4⚙️
Rectangular Fire Dampers, Type HXFD Class A60
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000527
⚙️
Round Fire Dampers, Type HXFD Class A60
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000528
⚙️
Bulkhead Fire Dampers Type HXFD Class A-0
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000828
⚙️
Deck Fire Dampers,Type HXFD Class A-0
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000829
🏭
Fehrmann
4⚙️
A-0 Fixed Fire Rated Window (Pyran S 10 mm)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008FB
⚙️
Certificate MEDD00002DW
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00002DW
⚙️
A-60 Fire Rated Fixed Window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008D7
⚙️
A-0 Fire Rated Window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008D9
🏭
Insulcon Technical
4⚙️
Jet Fire Pro PFP Jacket
source: dnv-approval-finder
model_number: TAF000021A
⚙️
AIS "Jet Fire Pro 120" Jacketing System
source: dnv-approval-finder
model_number: TAF00001C1
⚙️
Jet Fire Pro Enclosure
source: dnv-approval-finder
model_number: TAF00000SY
⚙️
Jet Fire Pro Flexible Fire Protection Jacket
source: dnv-approval-finder
model_number: TAF000001A
🏭
InterDam Holding
4⚙️
A-60 fire rated wall system type G21 Fire Panel
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000471
⚙️
A 60 Fire Door GADAM 2
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000016C
⚙️
IDM-SLS-H120 Fire Door
source: dnv-approval-finder
model_number: TAF00000TE
⚙️
IDM-SLH-H120 Fire Door
source: dnv-approval-finder
model_number: TAF00000TD
🏭
ISOPARTNER Nederland
4⚙️
Surface Finish Material – Type: ‘Airisol Aluminium 20 micron grp reinforced’ aluminium foil reinforced with GRP bonded to non-combustible substrate (18kg/m³ or higher density). Substrate may be produced in profiled shape type ‘Airisol/CalRoc Profile insulation’. (Airisol Aluminium 20 micron grp reinforced)
source: uk-mca
model_number: LR2593969UKMB
⚙️
Surface Finish Material – Type: ‘Airisol Marine Cloth’ fibre fabric material bonded to non-combustible substrate (18 kg/m³ or higher density). Substrate may be produced in profiled shape type ‘Airisol/CalRoc Profile insulation’ (Airisol Marine Cloth)
source: uk-mca
model_number: LR2593972UKMB
⚙️
Surface Finish Material – Type: ‘Airisol Aluminium 50 microns’ aluminium foil
reinforced with GRP bonded to non-combustible substrate (18kg/m³ or higher density). Substrate may be produced in profiled shape type ‘Airisol/CalRoc Profile insulation’. (Airisol aluminium 50 microns)
source: uk-mca
model_number: LR2593973UKMB
⚙️
Fire Resisting Material – Type: “Airisol Flex” and “Airisol Board” (24-78 kg/m³) (Airisol Flex” and “Airisol Board”)
source: uk-mca
model_number: LR2656470UKMD
🏭
Jewel Fire
4⚙️
5CX, 5kg Carbon Dioxide Fire Extinguisher, Fire Rating 55B.
source: uk-mca
model_number: BSI/UK/3.2/658603
⚙️
6WMX, 6 Litre Water Mist Fire Extinguisher, Fire Rating 13A, 75F.
source: uk-mca
model_number: BSI/UK/3.2/665640
⚙️
2CX, 2kg Carbon Dioxide Fire Extinguisher, Fire Rating 34B.
source: uk-mca
model_number: BSI/UK/3.38/658602
⚙️
3WMX, 3 Litre Water Mist Fire Extinguisher, Fire Rating 8A, 25F.
source: uk-mca
model_number: BSI/UK/3.38/670818
🏭
Jiangsu Josun Air Conditioner
4⚙️
Bulkhead Fire Dampers CSFH, CDFH, CQFH, CDFHD and CQFHD
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008GF
⚙️
Certificate MEDD00002ES
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00002ES
⚙️
Bulkhead Fire Dampers CDFH, CSFH and CQFHD
source: dnv-approval-finder
model_number: TAF00001T8
⚙️
Deck Fire Dampers CDFH and CQFHD
source: dnv-approval-finder
model_number: TAF00001TB
🏭
Jiangsu Sanxian Shipping Equipment
4⚙️
CFH-S (Ø400-B and Ø100-B)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007DZ
⚙️
CFHCD-S (510x510-B), CFH-D (500x700-B), CFH-S (120x120-B), CFHD-S (300x400-B), CFHCD-S (300x400-B), CFHCD-Q (1650x1650-B)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007DX
⚙️
CFHD-Q (1600x2000-B)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007E0
⚙️
CFHD-S (Ø350-D), CFHCD-Q (Ø1600-D), CFHCD-S (Ø350-D), CFH-D (Ø400-D) and CFH-S (Ø100-D)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007DY
🏭
KZWM Ogniochron
4⚙️
GP-6x ABC/MP - 6kg ABC Dry Powder, Stored Pressure Fire Extinguisher; GP-9x ABC/MP - 9kg ABC Dry Powder, Stored Pressure Fire Extinguisher.
source: uk-mca
model_number: BSI/UK/3.2/755099
⚙️
GPN-3x ABF/W – 3 Litre Foam, Stored Pressure Fire Extinguisher; GPN-3x AB/FF - 3 Litre Foam, Stored Pressure Fire Extinguisher;
source: uk-mca
model_number: BSI/UK/3.2/755104
⚙️
GW-6x A/MP - 6 Litre Water, Stored Pressure Fire Extinguisher. GW-9x A/MP - 9 Litre Water, Stored Pressure Fire Extinguisher. GWM-6x AF/MP - 6 Litre Water-mist, Stored Pressure Fire Extinguisher. GW-6x AF/FLF - 6 Litre Water + Additive, Stored Pressure Fire Extinguisher. GW-9x A/FLF - 9 Litre Water + Additive, Stored Pressure Fire Extinguisher.
source: uk-mca
model_number: BSI/UK/3.2/755106
⚙️
GP-1z BC/M - 1kg BC Powder, Cartridge Operated Fire Extinguisher.
GP-1x ABC/M - 1kg ABC Powder, Stored Pressure Fire Extinguisher.
GP-2x ABC - 2kg ABC Powder, Stored Pressure Fire Extinguisher.
GP-3x ABC/MP - 3kg ABC Powder, Stored Pressure Fire Extinguisher.
GPN-2x ABF/M - 2 Litre Foam, Stored Pressure Fire Extinguisher.
GWM-3x AF/M - 3 Litre Water-mist, Stored Pressure Fire Extinguisher.
GW-3x A/FLF - 3 Litre Water + Additive, Stored Pressure Fire Extinguisher.
source: uk-mca
model_number: BSI/UK/3.38/755103
🏭
Langfang The Great Wall Ship Glass Belt
4⚙️
Ceramic Wool Fire Deck
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00009C9
⚙️
Certificate MEDD00001RJ
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00001RJ
⚙️
LYG Type Class A-60 Fire Bulkhead
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004TJ
⚙️
LYG Type Class A-60 Fire Deck
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004TK
🏭
MINERALKA d.o.o
4⚙️
FIPRO (800 kg/m³), FIPRO MS (650 kg/m³), FIPRO Light 500 (500 kg/m³) and FIPRO Light 400 (400 kg/m³)
source: uk-mca
model_number: 76379/A0 UK
⚙️
B-15 Class Bulkhead FIPRO MS
source: uk-mca
model_number: 76380/A0 UK
⚙️
B-0 Class Bulkhead "FIPRO MS"
source: uk-mca
model_number: 76382/A0 UK
⚙️
A-60 Class Light Weight Bulkhead FIPRO or FIPRO MS
source: uk-mca
model_number: SMS.UK.D/17/A.0
🏭
Moyne Roberts
4⚙️
MP-MF-MW-XF-XW-MWF series
source: uk-mca
model_number: 2023/IL-UK/1031 1 rev.0
⚙️
Mobile Fire extinguishers : MVP-MVF series
source: uk-mca
model_number: 23/GB-UK/1023-0-Rev.0
⚙️
Portable Fire extinguishers: MP-MF-MW-XF-XW-MWF series
source: uk-mca
model_number: 23/GB-UK/1031-0-Rev.0
⚙️
Mobile Fire extinguishers : MP-MF-MW-XF-XW-MWF series
source: uk-mca
model_number: 23/GB-UK/1032-0-Rev.0
🏭
NewAge Fire Protection Industries
4⚙️
FYRFYTER, PREMIER, SUPREME, FIRE MASTER SUPER, COMMANDER SUPER, FIRE CHIEF or FIRE OUT RRL
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00003X4
⚙️
FYRFYTER SUPER, PREMIER EXTRA, SUPREME EXTRA, FIRE MASTER SUPER RED, COMMANDER SUPER RED, NOVA DURA or PYROLINE
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00003X5
⚙️
FYRFYTER SUPER, PREMIER EXTRA, SUPREME EXTRA, FIRE MASTER SUPER RED, COMMANDER SUPER RED, NOVA DURA, PYROLINE
source: dnv-approval-finder
model_number: TAF00001EU
⚙️
FYRFYTER, PREMIER, SUPREME, FIRE MASTER SUPER, COMMANDER SUPER, FIRE CHIEF, FIRE OUT RRL
source: dnv-approval-finder
model_number: TAF00001EV
🏭
NK
4⚙️
Fixed Type High Pressure CO2 Fire Extinguishing System
source: dnv-approval-finder
model_number: TAF00000U9
⚙️
N2 Fire Extinguishing System
source: dnv-approval-finder
model_number: TAF00000VA
⚙️
Fixed water-based local application fire extinguishing system
source: dnv-approval-finder
model_number: TAF00000A8
⚙️
NK High Pressure Marine Carbon Dioxide Fire Extinguishing Systems.
source: uscg-cgmix
model_number: 162.038/13/0
🏭
Omexco
4⚙️
Decorative FR wall covering made of printed viscose yarns surface and a 90 g/m² backing layer (44% wood pulp, 16% polyester, 40% binders and mineral fillers) _ 270g/m² - 320g/m² (Decorative screen printed warps on non-woven)
source: uk-mca
model_number: UK_2023_0053_B
⚙️
Decorative FR wall covering made of a printed 160 g/m² non-woven backing layer (42% cellulose, 18% polyester, 40% binders and mineral fillers) _ 150g/m² - 250g/m² (Decorative screen printed non-woven)
source: uk-mca
model_number: UK_2023_0054_B
⚙️
Decorative FR wall covering made of a printed 240 g/m2 non-woven backing layer (44-52% Cellulose, 17-21% Polyester, 15-23% binder, 10-18% mineral pigments) (Decorative screen printed non-woven)
source: uk-mca
model_number: UK_2023_0055_B
⚙️
Decorative FR wall covering made of mica on a 90 g/m2 non-woven backing layer (Mica on nonwoven backing)
source: uk-mca
model_number: UK_2023_0064_B
🏭
PJ Fire
4⚙️
5CDKT - 5kg CO2 Extinguisher, Aluminium Cylinder with Steel & Plastic T Bracket.
source: uk-mca
model_number: BSI/UK/3.2/557846
⚙️
5CD - 5kg CO2 Extinguisher, Aluminium Cylinder with Steel & Plastic T Bracket.
source: uk-mca
model_number: BSI/UK/3.2/579000
⚙️
2CDKL - 2kg CO2 Extinguisher, Aluminium Cylinder with Steel Lug Bracket; 2CDKT - 2kg CO2 Extinguisher, Aluminium Cylinder with Steel & Plastic T Bracket.
source: uk-mca
model_number: BSI/UK/3.38/557847
⚙️
2CDKL – 2kg CO2 Extinguisher, Aluminum Cylinder with Steel Lug Bracket.
source: uk-mca
model_number: BSI/UK/3.38/577809
🏭
Taixing Hualong Shipping Machinery
4⚙️
Bulkhead Fire Damper HLCF
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004AF
⚙️
Round deck fire damper HLCF-S(D&Q)/DM
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004AH
⚙️
Rectangular Bulkhead Fire Damper HLCF
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004AE
⚙️
Bulkhead fire damper HLCF
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004AG
🏭
Taizhou Hujiang Special Equipment
4⚙️
Circular bulkhead fire damper type: CFHIID 2000-Q
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00005DW
⚙️
Circular bulkhead fire damper Type: CFHIICD 2000-Q
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00005E0
⚙️
Circular deck fire damper Type: CFHIIJD 2000-Q
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00005E1
⚙️
Rectangular bulkhead fire damper Type CFHIID 1600x1200-Q
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00005DX
🏭
3M
3⚙️
"3M Safety-Walk Slip-Resistant General Purpose Tapes and Treads - 610" is approved as meeting Parts 2 and 5 of Annex 1 of the 2010 FTP Code.
source: uscg-cgmix
model_number: 164.117/50/0
⚙️
Di-Noc Architectural Finishes, as identified by product number in Enclosure (1) of USCG letter dated December 18, 2025, are approved as meeting Parts 2 and 5 of Annex 1 of the IMO FTP Code.
source: uscg-cgmix
model_number: 164.112/151/0
⚙️
3M Fasara Glass Film finishes, as identified by product number in Enclosure (1) of USCG letter dated April 2, 2015, are approved as meeting Parts 2 and 5 of Annex 1 of the 2010 IMO FTP Code.
source: uscg-cgmix
model_number: 164.112/157/0
🏭
Abet High Tech Solutions
3⚙️
Surface materials and floor coverings with low flame-spread characteristis:- decorative veneers (ESACORE AL ST BC MONOFACCIA)
source: uk-mca
model_number: LR23283747UKMB
⚙️
Aluminium Honeycomb Panel with Low Flame Spread Adhesive Type: " ESACORE AL ST BC MONOFACCIA" for use in C Class divisions. (ESACORE AL ST BC MONOFACCIA)
source: uk-mca
model_number: LR23285534UKMB
⚙️
Fire-Resisting Material - Sandwich Panel Composed of Decorative Laminate, Aluminium Sheets & Aluminium Honeycomb Type "ESACORE AL ST" (ESACORE AL ST)
source: uk-mca
model_number: LR24148095UKMF
🏭
BOSTIK
3⚙️
Flexible adhesive material, type "MSR-BC" / (maximum application rate: 124 g/m²)
source: uk-mca
model_number: 79048/A0 UK
⚙️
Flexible sealing/adhesive material, type "MSR-CA / MSR-CA sskf" / (maximum application rate: 170 g/m²)
source: uk-mca
model_number: 79050/A0 UK
⚙️
Flexible adhesive material, type "MSR-FT" / (maximum application rate: 179 g/m²)
source: uk-mca
model_number: 79051/A0 UK
🏭
Bru Textiles
3⚙️
FR – One Draperies: 100% Polyester inherent FR
100% recycled Polyester inherent FR
50% recycled Polyester inherent FR, 50% Polyester inherent FR
71.3% recycled Polyester inherent FR, 28.7% Polyester
95% recycled Polyester inherent FR, 5% Inherent FR Polyester
96% recycled Polyester inherent FR, 6% Inherent FR Polyester
54% recycled Polyester inherent FR, 46% IFR Polyester
56% recycled Polyester inherent FR, 44% Polyester inherent FR (Ataton
Architectural sheers
Calais
Marvell
Ma
source: uk-mca
model_number: UK_2023_0048_B
⚙️
FR – One Upholstery:
100% Polyester inherent FR
100% recycled Polyester inherent FR
50% recycled Polyester inherent FR, 50% Polyester inherent FR
70% recycled Polyester inherent FR, 30% Polyester
90% recycled Polyester inherent FR, 10% Inherent FR Polyester
95% recycled Polyester inherent FR, 5% Inherent FR Polyester
FR – One Artificial Leather: 78% PVC, 13% Polyester, 7% Cotton, 2% PU (Moon
Mythic
Miles
Genova
Golf
Jadeite
Jadore
Jovial
Jubilea
Prodigy
Cherish Velours
Chieftain
source: uk-mca
model_number: UK_2023_0049_B
⚙️
FR – One Bedding: 100% Polyester inherent FR
100% recycled Polyester inherent FR
50% recycled Polyester inherent FR, 50% Polyester inherent FR
71.3% recycled Polyester inherent FR, 28.7% Polyester
95% recycled Polyester inherent FR, 5% Inherent FR Polyester
96% recycled Polyester inherent FR, 6% Inherent FR Polyester
54% recycled Polyester inherent FR, 46% IFR Polyester
56% recycled Polyester inherent FR, 44% Polyester inherent FR (Liberate
Lexicon
Genova
Cherish Velours
Ludo
N
source: uk-mca
model_number: UK_2023_0050_B
🏭
Ceasefire Industries U.K
3⚙️
Portable fire extinguisher (** - 000698)
source: uk-mca
model_number: 0832-UKCA-MED-S3003
⚙️
Portable fire extinguisher (** - 000696)
source: uk-mca
model_number: 0832-UKCA-MED-S3004
⚙️
Mobile fire extinguisher (** - 000741)
source: uk-mca
model_number: 0832-UKCA-MED-S3005
🏭
China Shipbuilding Jiujiang Haike Interior Decoration
3⚙️
A-15 Fire Door MA15TX-II
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008J6
⚙️
A-60 Fire Door MA60T
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008J5
⚙️
DTA60 Type Class A60 Elevator Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000879
🏭
Danfoss Power Solutions II
3⚙️
Hoses 2807, GH194, GH585, FC350 with Fire Sleeve 624
source: dnv-approval-finder
model_number: TAP000023T
⚙️
GH100 + Fire Sleeve 624
source: dnv-approval-finder
model_number: TAP000031V
⚙️
FC350 with FIRE SLEEVE 624
source: dnv-approval-finder
model_number: TAP00000BC
🏭
DECKMA-Decksmaschinen und Automation Vertriebsgesellschaft mit beschränkter Haftung
3⚙️
Conventional Fire Detection and Alarm System FMS3000
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000BWZ
⚙️
Addressable Fire Detection and Alarm System AFMS3000
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000BG8
⚙️
Certificate MEDE000001M
imo_approved: True
source: dnv-approval-finder
model_number: MEDE000001M
🏭
Detector Electronics
3⚙️
Eagle Quantum Premier Fire and Gas Detection / Releasing System (EQP System)
source: dnv-approval-finder
model_number: TAA0000121
⚙️
Eagle Quantum Premier System (EQP System) including control panel, detectors, and accessories.
source: uscg-cgmix
model_number: 161.002/49/0
⚙️
Det-Tronics SmokeWatch Model U5015 Explosion Proof Smoke Detector approved as a smoke detector, for use in Category 1, 2, & 3 spaces.
source: uscg-cgmix
model_number: 161.002/61/0
🏭
Durastic (Flooring)
3⚙️
MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF
PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION - Fire-Resisting Material - Primary Deck Covering Material (“Durastic Decorflake Epoxy Flooring”)
source: uk-mca
model_number: LR23143840UKMB
⚙️
MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF
PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION - Fire-Resisting Material - Primary Deck Covering Material (“S405 FR Epoxy”)
source: uk-mca
model_number: LR23144961UKMB
⚙️
Fire-Resisting Material – Type: “Durastic S229 Underlay” Deck Covering (Durastic S229 Underlay)
source: uk-mca
model_number: LR2512957UKMB
🏭
EUROPAIR
3⚙️
Certificate MEDD00002AF
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00002AF
⚙️
EUSD, EUSDX, EUSDB, EUSDBX (fire dampers for bulkhead and deck)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007XD
⚙️
EUSD, EUSDX, EUSBD, EUSDBX (fire dampers for bulkhead and deck)
source: dnv-approval-finder
model_number: TAF00001NZ
🏭
Fr. Fassmer
3⚙️
Model CL(R)-T Series, 5.9 through 9.8 m x 2.89 m, totally enclosed, fire-protected SOLAS lifeboat(CL)/rescue boat (CLR) of FRP construction with occupant capacity as listed below.
source: uscg-cgmix
model_number: 160.135/63/0
⚙️
Model CLX-T (tanker) series: 8.5, 10.0, 11.7 & 12.8; 8.5 to 12.8 m x 3.35 m x 1.30 m, totally enclosed fire-protected SOLAS lifeboat of fiberglass reinforced plastic construction.
source: uscg-cgmix
model_number: 160.135/113/0
⚙️
Model CLR-T 5.9 through 8.5 m x 2.89 m, totally enclosed, fire-protected lifeboat/rescue boat of FRP construction with occupant capacity as listed below.
source: uscg-cgmix
model_number: 160.156/63/0
🏭
Halton Marine
3⚙️
FDO MARINE FIRE DAMPER
source: dnv-approval-finder
model_number: TAF00000CF
⚙️
Single and Multiblade Fire Damper Types FDB2-EL, FDB2-PNL, FDB2-PNR and FDB2-SP
source: dnv-approval-finder
model_number: TAF00000CH
⚙️
FDA Fire Damper
source: dnv-approval-finder
model_number: TAF00000CJ
🏭
IDEMARINE HUSNA GEMI SAN. VE TIC. LTD. STI
3⚙️
A-0 Class Rectangular Non-Opening Window, type "A0 Ship windows"
source: uk-mca
model_number: 75977/A0 UK
⚙️
A-60 Class Rectangular Non-Opening Window, type "A60 Fire Ship windows"
source: uk-mca
model_number: 75980/A0 UK
⚙️
A-0 Class Circular Non-Opening Sidescuttle, type A0 Circular Fire Class Side Scuttle
source: uk-mca
model_number: SMS.UK.D/55029/A.0
🏭
Izo Tech Osadnik
3⚙️
iT-C930HT - JB2024122503 (100m), JB2025061702 (1150m), JB2025061703 (1000m)
source: uk-mca
model_number: MERF000022G
⚙️
iT-C430S1 - JB2025032901 (479m), JB2025040301 (3008m), JB2025050903 (3960m), JB2025051902 (3061m)
source: uk-mca
model_number: MERF000022H
⚙️
iT-C430P1 - JB2025050708 (10500m)
source: uk-mca
model_number: MERF000022J
🏭
JIANGSU FENGSHUN NEW MATERIAL TECHNOLOGY
3⚙️
FS-MA0-1 Type A-0 Class Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000B0S
⚙️
FS-MA60-1 Type A-60 Class Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000B0T
⚙️
FS-SMA60-1 Type A-60 Class Double-Leaf Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000B0U
🏭
Jiangsu Hongyu Marine Equipment
3⚙️
Bulkhead Fire Dampers
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008JB
⚙️
Certificate MEDD00000X8
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00000X8
⚙️
Automatic Fail-Safe Marine Fire Damper (Deck): HYSF, HYDF and HYQF
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000021C
🏭
Kidde Fire Protection
3⚙️
MARINE CO2 FIXED FIRE SUPPRESSION SYSTEM
source: dnv-approval-finder
model_number: TAF0000027
⚙️
Type "ARGONITE"
source: uk-mca
model_number: 74170/A0 UK
⚙️
Novec 1230 / Fluoro-K ECS 360 psi
source: uk-mca
model_number: SMS.UK.D/65403/B.1
🏭
LMG Finland
3⚙️
Fire door, Model E
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00001F3
⚙️
Fire Door, Model F
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000098X
⚙️
Certificate MEDE000001U
imo_approved: True
source: dnv-approval-finder
model_number: MEDE000001U
🏭
Macron Safety Systems
3⚙️
Fixed Gas Fire Extinguishing System – Type: “HYGOOD SAPPHIRE (NOVEC 1230 or
equivalent FK-5-1-12 extinguishant) Total Flood Fire Suppression 25 bar,
42 bar and 70 bar Systems” using 180° Nozzles (25mm to 50mm) and 360° Nozzles
(25mm only), for Machinery Spaces of Category A and Cargo Pump Rooms,
equivalent to fire-extinguishing systems required by SOLAS 1974 as amended,
Chapter II-2/10.5 and 10.9. (HYGOOD SAPPHIRE (NOVEC 1230; FK-5-1-12) Total Flood Fire Suppression
25 bar, 42 bar and
source: uk-mca
model_number: LR22453082UKMB-02
⚙️
Fixed Gas Fire Extinguishing System – Type: “GEM SAPPHIRE (NOVEC 1230 or
equivalent FK-5-1-12 extinguishant) Total Flood Fire Suppression 25 bar, 42 bar
and 70 bar Systems” using 180° Nozzles (25mm to 50mm) and 360° Nozzles
(25mm only), for Machinery Spaces of Category A and Cargo Pump Rooms,
equivalent to fire- extinguishing systems required by SOLAS 1974 as amended,
Chapter II-2/10.5 and 10.9. (GEM SAPPHIRE Total Flood Fire Suppression 25 bar, 42 bar and 70 bar Systems.)
source: uk-mca
model_number: LR23159713UKMB-01
⚙️
Equivalent fixed gas fire extinguishing systems components (extinguishing medium, head valves and nozzles) for machinery spaces and cargo pump rooms
source: uk-mca
model_number: LR25214179UKMD
🏭
NEWMOR
3⚙️
Premier Fabric Backed Wallcovering / ("Premier cotton fabric backed wall covering (400 g/m²)" and "Premier nonwoven fabric backed wallcovering (400 g/m²)")
source: uk-mca
model_number: 74277/A0 UK
⚙️
Premier 460 gsm Nonwoven-backed Vinyl Wallcovering (460 g/m²)
source: uk-mca
model_number: 77325/A0 UK
⚙️
Premier 460 gsm Type II Fabric-backed Vinyl Wallcovering (460 g/m²)
source: uk-mca
model_number: 80719/A0 UK
🏭
Nu-Swift
3⚙️
Description: Portable Fire Extinguishers (CO2)
DA-1550 QE; SW 1550 QE
source: uk-mca
model_number: 23/GB-UK/1024-0-rev.0
⚙️
Description: Portable Fire Extinguishers (Stored Pressure)
6044;6066;6099;6088
source: uk-mca
model_number: 23/GB-UK/1025-0-rev.0
⚙️
Description: Portable Fire Extinguishers (Stored Pressure)
6201;6202;6203;6204;2SP12P
source: uk-mca
model_number: 23/GB-UK/5108-0-rev.0
🏭
NVL B.V. &
3⚙️
Certificate MEDD00002H2
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00002H2
⚙️
NV1 A0 Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008VY
⚙️
NV1 A60 Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008VX
🏭
PANELSHIP
3⚙️
A' & 'B' Class Divisions Fire Integrity: 'B' Class Divisions (TGS B-15 Panel 50mm)
source: uk-mca
model_number: LR23374974UKMB
⚙️
Fire Resisting ‘B’ Class Bulkhead Panel System – Type ”TGS B-15 Panel 25mm” (TGS B-15 Panel 25mm)
source: uk-mca
model_number: LR23375011UKMB
⚙️
A' & 'B' Class Divisions Fire Integrity: 'B' Class Divisions
source: uk-mca
model_number: LR2670815UKMD-02
🏭
Promat Research and Technology Centre
3⚙️
B-15 Class Bulkhead, type "2.5m PLURATECT MARINE LIGHT B15"
source: uk-mca
model_number: 77585/A0 UK
⚙️
B-15 Class Bulkhead, type "3 m PLURATECT MARINE PLUS B15"
source: uk-mca
model_number: 77600/A0 UK
⚙️
B CLASS DIVISIONS, BULKHEAD PANELS, FIRE INTEGRITY - PROMARINE (R)
source: uk-mca
model_number: SMS.UK.D/146920/A.0
🏭
QINHUANGDAO XINGYANG MARINE FITTING
3⚙️
A-0 Class Fixed Fire Rectangular Window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00005MM
⚙️
P-1084x1654x75-NOW-2020-A60-Rw Type Class A-60 Fire Window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00001A0
⚙️
A0SM0.1~0.5 Type Class A-0 Hinged Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000015H
🏭
SM Tech
3⚙️
SMT Fire Stop System-07
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00001A6
⚙️
Fire stop sheet
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00000VK
⚙️
SMT FIRE DELAY SHEET - Flexible Fabric
source: dnv-approval-finder
model_number: TAF00000C8
🏭
Taizhou Qiankun Shipping Machinery
3⚙️
Rectangular Fire Damper CF-D-J
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00005GG
⚙️
Rectangular Fire Damper CF-Q-D-J, CF-D-J
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00005GE
⚙️
Round Fire Damper CF-Q-D-Y, CF-S-Y
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00005GF
🏭
TERMIKA
3⚙️
Termika Glass Cloth Tape ST1 / Termika Glass Cloth Tape ST55 / Termika Glass Cloth Tape SA125
source: uk-mca
model_number: 77660/A0 UK
⚙️
TERMIKA ALUFOIL 35000
source: uk-mca
model_number: 77662/A0 UK
⚙️
Termika Glass Cloth ST 1 (430±21 g/m²), Termika Glass Cloth ST 55 (215±10 g/m²)
source: uk-mca
model_number: 77663/A0 UK
🏭
Tianjin Haimen Building Material
3⚙️
HMLB Fire retarding Composite Aluminium foil glass fiber cloth
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008JX
⚙️
HMTB-96 Type Class A-60 Fire Bulkhead
source: dnv-approval-finder
model_number: TAF0000149
⚙️
HMTD-96 Type Class A-60 Fire Deck
source: dnv-approval-finder
model_number: TAF000014H
🏭
Tyco Fire Products, LP
3⚙️
ANSUL R-102 Fire Suppression System
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000088R
⚙️
Ansul R-102 Fire Suppression system
source: dnv-approval-finder
model_number: TAF00000ZT
⚙️
ANSUL MARINE INERGEN FIRE SUPPRESSION SYSTEM
source: dnv-approval-finder
model_number: TAF0000050
🏭
Tyco Fire Protection Products
3⚙️
Model EF12681 Foam Stations approved for use as excess equipment for protection of helicopter landing pads on mobile offshore drilling units without refueling facilities.
source: uscg-cgmix
model_number: 162.033/42/2
⚙️
Model EF12681 AFFF Foam Stations approved for use as required fire main system equipment.
source: uscg-cgmix
model_number: 162.033/43/2
⚙️
Model EF12680 Foam Stations approved for use as required fire main system equipment.
source: uscg-cgmix
model_number: 162.033/44/2
🏭
Vid Fire-Kill ApS
3⚙️
“VID Fire-Kill K6 Pacific Fine Water Spray” (ceiling), “VID Fire-Kill K6 North Sea Fine Water Spray” (ceiling), “VID Fire-Kill K6 Mediterranean Fine Water Spray” (ceiling), “VID Fire-Kill K1 Biscay Water Mist” (bilge), “VID Fire-Kill F1 Tampa Fine Water Spray” (bilge), “VID Fire-Kill B1 Hudson” (bilge) and “VID Fire-Kill B1 Bengal (bilge)”
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00002S1
⚙️
VID Fire-Kill K6 Pacific Fine Water Spray (ceiling), VID Fire-Kill K6 North Sea Fine Water Spray (ceiling), VID Fire-Kill K6 Mediterranean Fine Water Spray (ceiling), VID Fire-Kill K1 Biscay Water Mist (bilge), VID Fire-Kill F1 Tampa Water Mist (bilge), VID Fire-Kill B1 Hudson (bilge), VID Fire-Kill B1 Bengal (bilge)
source: dnv-approval-finder
model_number: TAF00000D7
⚙️
“VID Fire-Kill K6 Pacific Fine Water Spray” (ceiling), “VID Fire-Kill K6 North Sea Fine Water Spray” (ceiling),...
source: dnv-approval-finder
model_number: MERB00002S1
🏭
WKE-Kohlstedt
3⚙️
Horizontal A-60 class fire closure for use in an A-class linen chute
imo_approved: True
source: dnv-approval-finder
model_number: 9538714 HH
⚙️
Horizontal A-60 class fire closure in an A-class linen chute
imo_approved: True
source: dnv-approval-finder
model_number: 1492715 HH
⚙️
Class A-60 fire closure
imo_approved: True
source: dnv-approval-finder
model_number: 3774612 HH
🏭
ZHEJIANG MINHUI LUMINOUS TECHNOLOGY
3⚙️
Certificate MEDD0000507
imo_approved: True
source: dnv-approval-finder
model_number: MEDD0000507
⚙️
After-glow luminescent Secure Indication System Fire Safety Signs of types:MHF-G100P, MHF-G150P, MHF-G300P, MHF-G500P
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000B41
⚙️
After-Glow Luminescent Secure Indication System Fire Safety Signs type MHF-G100P
source: dnv-approval-finder
model_number: TAE00003WG
🏭
Advanced Innergy
2⚙️
ContraFlame C20 Flexible Jet Fire Barrier
source: dnv-approval-finder
model_number: TAF00001AA
⚙️
ContraFlame - Fire barrier
source: dnv-approval-finder
model_number: TAF000010K
🏭
Amerex
2⚙️
Certificate MEDD00000SW
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00000SW
⚙️
Amerex KP Fire Suppression System KP250 and KP375
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00000DE
🏭
Ansell Protective Solutions
2⚙️
AlphaTec EVO type CV-ET and type VP1-ET
source: dnv-approval-finder
model_number: TAF00001HH
⚙️
AlphaTec EVO Type T-ET
source: dnv-approval-finder
model_number: TAF00001HJ
🏭
Ardex UK
2⚙️
Ardex FA 20 (Ardex X 77 S)
source: uk-mca
model_number: 164.106\1121\WCL MER0321QA
⚙️
Ardex P 82
source: uk-mca
model_number: 164.112\1121\WCL MER0323QA
🏭
AXALTA COATING SYSTEMS FRANCE S
2⚙️
Alesta® AP / Teodur® AP
source: uk-mca
model_number: 74100/A1 UK
⚙️
ALESTA EP® / TEODUR EP® (max. application rate 120 g/m²)
source: uk-mca
model_number: 74259/A1 UK
🏭
Baggerød
2⚙️
A-60 Window - Hero-fire
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000008M
⚙️
A-60 Double Leaf Hinged Door, Type HB5000 DD
source: uk-mca
model_number: MERB000061T-0
🏭
BALL & YOUNG
2⚙️
Floor Coverings / Carpet underlays: / Type Cast Iron FR / Contract 6 mm FR / Cruise Liner FR, / Type Cast Iron 8mm FR / Contract 8 FR / Cruise Liner 8 FR and / Type Cloud 9 Flame Retardant 6 / Cloud 9 Flame Retardant 8 / Cloud 9 Flame Retardant 4
source: uk-mca
model_number: 74168/A0 UK
⚙️
Floor Coverings / Carpet underlays:
source: uk-mca
model_number: SMS.UK.D/2267/A.0
🏭
BOHAMET
2⚙️
Class A-60 Fire door - BOH.0340.II
source: dnv-approval-finder
model_number: MERB00008SE
⚙️
A30 Class Fixed Multipart Window (glued from outside) (A30 CLASS FIXED MULTIPART BONDED WINDOW)
source: uk-mca
model_number: LR2664486UKMB
🏭
Braunschweiger Flammenfilter
2⚙️
PROTEGO® DE/S-MK VI-10-80
imo_approved: True
source: dnv-approval-finder
model_number: 3799512 HH
⚙️
PROTEGO SV/E-S-80-IIB3
imo_approved: True
source: dnv-approval-finder
model_number: 1261410 HH
🏭
BY Controls
2⚙️
WTHS A-60 Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00005FR
⚙️
Fire door "A-type"
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004DH
🏭
DONGNAN ELEVATOR
2⚙️
Certificate MEDD00002H1
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00002H1
⚙️
FDS2C-A-0.1 Type Class A-0 Marine Elevator Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008VN
🏭
DSG
2⚙️
fire door
imo_approved: True
source: dnv-approval-finder
model_number: 4330602 Lux
⚙️
E3000-L-400
imo_approved: True
source: dnv-approval-finder
model_number: 2054104 Lux
🏭
DuPont Speciality Products USA
2⚙️
Surface materials and floor coverings with Low flame-spread characteristics:- flooring coverings (“CORIAN® SOLID SURFACE” (FR-Grade, U-Series, Solid Colors, 12 mm))
source: uk-mca
model_number: LR24114522UKMB
⚙️
Surface materials and floor coverings with Low flame-spread characteristics:- decorative veneers (“CORIAN® SOLID SURFACE” (FR-Grade, U-Series, Solid Colors, 12 mm))
source: uk-mca
model_number: LR24114536UKMB
🏭
Eindec Singapore
2⚙️
Marine Bulkhead Fire Dampers FGD-H-E and FGD-H-P
source: dnv-approval-finder
model_number: TAF000005B
⚙️
Marine Deck Fire Damper FGD-H-E / FGD-H-P
source: dnv-approval-finder
model_number: TAF000005E
🏭
FAMOS Marine Interior Systems
2⚙️
Fire Resisting Single Leaf Hinged Door – Type"Segment drzwiowy klasy B 15 B19001" (Segment drzwiowy klasy B 15 B19001)
source: uk-mca
model_number: LR23271598UKMB-02
⚙️
Fire Resisting B Class Panel System – Type: “S/B-13-060 zm.b” (S/B-13-060 zm.b” B-15 Bulkhead)
source: uk-mca
model_number: LR2538282UKMB-01
🏭
Fire Security
2⚙️
Fire Sec FS 5
source: dnv-approval-finder
model_number: TAE00001JB
⚙️
Fire Sec FS 1
source: dnv-approval-finder
model_number: TAE00001JA
🏭
Firsquare Energy (Shanghai)
2⚙️
Certificate MEDD000058D
imo_approved: True
source: dnv-approval-finder
model_number: MEDD000058D
⚙️
A-60 Fire Damper Type: SFGD
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000C27
🏭
FORMICA EUROPE
2⚙️
Formica Laminate HGS / HGP (0.7 - 0.9 mm)
source: uk-mca
model_number: 74217/A0 UK
⚙️
Formica Laminate HGF / VFP (0.7-1.2 mm)
source: uk-mca
model_number: 74267/A0 UK
🏭
Giordani Giancarlo
2⚙️
Five Finger Gloves for Fire Fighters Type 301.23
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006R4
⚙️
Certificate MEDD00001HZ
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00001HZ
🏭
Grama Blend
2⚙️
Surface materials and floor coverings with low flame-spread characteristics: - decorative veneers (Blendstone)
source: uk-mca
model_number: LR24128651UKMD
⚙️
Fire-Resisting Material - MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION (Blendstone)
source: uk-mca
model_number: LR2453673UKMB
🏭
Haein Industrial
2⚙️
Certificate MEDD000027U
imo_approved: True
source: dnv-approval-finder
model_number: MEDD000027U
⚙️
AMEREX COBRA Fixed fire extinguishing system for deep fat cooking equipment
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007AF
🏭
Hilti
2⚙️
Multi Pipe Transits - Fire Stop: CFS-T SS, CFS-T SSF, CFS-T SSR, CFS-T SSR/R30, CFS-T RR
source: dnv-approval-finder
model_number: TAF00001GY
⚙️
Multi Cable Transits - Fire Stop: CFS-T SS, CFS-T SSF, CFS-T SSR, CFS-T SSR/R30, CFS-T RR, CFS-T RRS
source: dnv-approval-finder
model_number: TAF000012B
🏭
IBMO
2⚙️
Flex Fire Seal
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000BTG
⚙️
IBMO Flex Fire Seal
source: dnv-approval-finder
model_number: TAF00001W4
🏭
Jiangsu Huayan Marine Equipment
2⚙️
HWAYAN/RHZK 6/30-W and HWAYAN/RHZK 6.8/30-W positive pressure fire-fighting air respirator with full face mask
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00003AK
⚙️
RHZK 6/30 and RHZK 6.8/30 positive pressure fire-fighting air respirator with full face mask
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000169
🏭
JiangSu Sooloong Hose MFG
2⚙️
Certificate MEDD00002FM
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00002FM
⚙️
45-EPDM; 52-EPDM; 40-PVC; 45-PVC; 52-PVC fire hoses
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008E4
🏭
Jiangxi Chao Yang Machinery
2⚙️
Fire Resisting 'A' Class Singele Leaf Sliding - Type "YMA60 Class A60 Sliding Door" (YMA60 Class A60 Sliding Door)
source: uk-mca
model_number: LR23408743UKMB
⚙️
FIRE DOORS (YMA60 Class A60 Sliding Door)
source: uk-mca
model_number: LR23418743UKMB
🏭
JMB
2⚙️
MATERIAL HAVING QUALITIES OF RESISTANCE TO THE IGNITION & PROPAGATION OF FLAME - Fire-Resisting Bedding Material - Mattresses (M–MK VIOLA)
source: uk-mca
model_number: LR23215023UKMB
⚙️
MATERIAL HAVING QUALITIES OF RESISTANCE TO THE IGNITION & PROPAGATION OF FLAME - Fire-Resisting Bedding Material - Mattresses (M–MS 2)
source: uk-mca
model_number: LR23215243UKMB
🏭
Macron Safety Systems (UK)
2⚙️
SAPPHIRE Fire Protection System, 25 bar, 42 bar and 70 bar systems
source: dnv-approval-finder
model_number: TAF00000UK
⚙️
Hygood, FM-200 Fixed fire suppresion system
source: dnv-approval-finder
model_number: TAF00000FG
🏭
Majilite
2⚙️
Novasuede IMO653
source: uk-mca
model_number: WCL1121/MER0374QARev.1
⚙️
WGA Wall Covering
source: uk-mca
model_number: WCL1121/MER0375QARev.1
🏭
Mascoat
2⚙️
Marine-DTM Anti-Condensation Coating approved as meeting Parts 2 and 5 of Annex 1 of the IMO FTP Code in a maximum dry thickness of 3 mm.
source: uscg-cgmix
model_number: 164.112/110/0
⚙️
Sound Control dB Coating approved as meeting Parts 2 and 5 of Annex 1 of the IMO FTP Code in a maximum dry thickness of 4 mm.
source: uscg-cgmix
model_number: 164.112/111/0
🏭
Microdata Due
2⚙️
Fire Detection MD Series
source: dnv-approval-finder
model_number: TAA0000042
⚙️
MD9902 – pn 26718
source: uk-mca
model_number: 8504-UKCA-MCA-UKCMA10012
🏭
Minimax
2⚙️
IG-541 Inert gas Fire-Extinguishing System Oxeo CF Marine
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000B3X
⚙️
IG-100 Inert gas Fire-Extinguishing System Oxeo CF Marine
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000B3Y
🏭
Nantong Cosy Marine Equipment Technology
2⚙️
KS-SMA60 Class A-60 Double Leaf Hinged Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000017B
⚙️
KS-DMA60 Class A-60 Single Leaf Hinged Fire Door
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000017A
🏭
NEK Kabel
2⚙️
QFCI-FV, QFCI-MICA, QFAI UNI, QFAI 2-UNI, QFNI, QFNB, QFXI, AFCI Fire
source: dnv-approval-finder
model_number: TAE00003MF
⚙️
LanMarin Fire CAT6A & CAT7 S/FTP
source: dnv-approval-finder
model_number: TAE00003VU
🏭
NewAge Fire Fighting
2⚙️
PREMIER, SUPREME, FIRE MASTER SUPER, COMMANDER SUPER, FIRE CHIEF, FIRE OUT RRL, FIRESTORM, AQUASTRIKE, FLAMEBLITZ
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000026U
⚙️
PREMIER EXTRA, SUPREME EXTRA, PYROLINE, NOVA DURA, FIRE MASTER SUPER RED, COMMANDER SUPER RED, FIRESTORM JET, AQUASTRIKE SUPER, FLAMEBLITZ RED
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000026V
🏭
NingBo Zhengxin Fire-Fighting Equipment
2⚙️
Mobile Fire extinguishers (powder-; water- and CO2 based) (NingBo Zhengxin Fire-Fighting Equipment Co. Ltd)
source: uk-mca
model_number: 25/CN-UK/5477-0-Rev.0
⚙️
Portable Fire Extinguishers (water-; powder- and CO2 based) (NingBo Zhengxin Fire-Fighting Equipment Co. Ltd)
source: uk-mca
model_number: 25-CN-UK-5475-0-Rev.0
🏭
Nohmi Bosai
2⚙️
FAC513/553 - Fire Alarm Panel FIR523/563 - Remote Annunciator
source: dnv-approval-finder
model_number: TAA00000D6
⚙️
Fire Alarm Panel VAPW501-R/U, Fire Indicator VICW501-R/U, Timer FYC512, All other units
source: dnv-approval-finder
model_number: TAA00000D7
🏭
Norma Czech, s.r.o
2⚙️
GRIP / GRIP E and Fire protected types FP, RFP
source: dnv-approval-finder
model_number: TAP000033X
⚙️
NORMACONNECT FLEX / FLEX E / FlexGrip / FlexGrip E and Fire protected types FP, RFP
source: dnv-approval-finder
model_number: TAP000032S
🏭
Ockwells
2⚙️
Ockwells Hard Surface Protection Film - Flame Retardant Certified Marine Grade
source: uk-mca
model_number: 1121\WCL MER0329QA
⚙️
Ockwells Carpet Protection Film - Flame Retardant Certified Marine Grade
source: uk-mca
model_number: 1121\WCL MER0330QA
🏭
Oy Saajos International
2⚙️
Single-leaf hinged fire door A-60 with window
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00003G4
⚙️
Double-leaf hinged marine fire door A-60
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00002ZK
🏭
Parmarine
2⚙️
A-60 Tandem sliding fire door
imo_approved: True
source: dnv-approval-finder
model_number: 3727512 HH
⚙️
single leaf hinged fire door
[max. clear opening: 1200 mm x 2400 mm (width x height)]
imo_approved: True
source: dnv-approval-finder
model_number: 3727312 HH
🏭
Pocadel
2⚙️
A' & 'B' Class Divisions Fire Integrity: 'B' Class Divisions (B-15 class partition)
source: uk-mca
model_number: LR2479972UKMB
⚙️
FIRE DOORS (B-15 Glazed Single Leaf DELI Sliding Door)
source: uk-mca
model_number: LR2479973UKMB
🏭
PROQUINAL S
2⚙️
MATERIALS HAVING QUALITIES OF RESISTANCE TO THE IGNITION AND PROPOGATION OF FLAME (“Spradling Collection”)
source: uk-mca
model_number: LR23412175UKMD
⚙️
MATERIALS HAVING QUALITIES OF RESISTANCE TO THE IGNITION AND PROPOGATION OF FLAME - Fire-Resisting Upholstery Material (“Spradling Collection”)
source: uk-mca
model_number: LR2492911UKMD
🏭
Roxtec International
2⚙️
SBTB Transit Frame System models 4X1 up to 8X4 meeting restricted H-120 criteria for steel bulkheads. Tested to the 2010 IMO FTP Code, Annex 1, Part 3, utilizing the hydrocarbon curve from ASTM E1529.
source: uscg-cgmix
model_number: 164.140/9/0
⚙️
"S" and "R" Series frames installed with Roxtec RM System including multidiameter technology and meeting restricted H-0 and H-60 criteria for steel bulkheads and decks.
source: uscg-cgmix
model_number: 164.140/10/0
🏭
Seongjee Engineering
2⚙️
A-0 Roll-up Fire Shutter (SJ-STD-RFS-01)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000072
⚙️
A-0 Wall Fire Shutter SJ-STD-WFS-01
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00002G0
🏭
Shenzhen Foresight
2⚙️
Certificate MEDD00000RH
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00000RH
⚙️
FS-60 Bulkhead, Deck Pipeline Fire-resistant Penetration Device
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000025T
🏭
Sherwin-Williams UK
2⚙️
Firetex M90/02 - Jet fire
source: dnv-approval-finder
model_number: TAF00000GY
⚙️
FIRETEX M90/02 - Bulkhead
source: dnv-approval-finder
model_number: TAF000006E
🏭
SUMITOMO RUBBER INDUSTRIES, LTD. Hybrid Rubber Products HQS
2⚙️
SEMTEX SX547 BM
source: uk-mca
model_number: 74180/A0 UK
⚙️
SEMTEX SEMLITE-C
source: uk-mca
model_number: 74181/A0 UK
🏭
Swegon Air Management Ltd (Actionair)
2⚙️
Fire Dampers (Standard Fire Tests) (A-60 Marine Fire Damper)
source: uk-mca
model_number: LR23326065UKMB
⚙️
Fire Dampers
source: uk-mca
model_number: LR25205334UKMD
🏭
Tata Steel Maubeuge
2⚙️
Advantica® GM Marine/ Advantica® GL Marine / Advantica® GH Marine /
Advantica® SDP35DC Marine
source: uk-mca
model_number: WCL1121/ MER0435QARev.1
⚙️
Advantica® L Decor Marine
source: uk-mca
model_number: WCL1121/MER0536QARev.1
🏭
Thermaflex Izolacji
2⚙️
Polyolefin foam covered with aluminium foil (ThermaSmart Marine 4.0)
source: uk-mca
model_number: LR24124420UKMD-01
⚙️
Surface Materials And Floor Coverings With Low Flame-Spread Characteristics: Pipe Insulation Covers (ThermaMount Marine, ThermaMount Marine flex)
source: uk-mca
model_number: LR2472593UKMB
🏭
Ucalsa Industrial Vigo
2⚙️
U-FR-01 (Fire Door A-15)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004EA
⚙️
U-FR-10 (Fire Door A-15)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004KR
🏭
Viking Life-Saving Equipment
2⚙️
Fire fighter garment CA AB – Model PS65xx / Layer code 03.00.11.10
source: uk-mca
model_number: UK_2022_0016_B
⚙️
Fire fighter garment CA AF – Model PS84xx / Layer code 03.22.10.10
source: uk-mca
model_number: UK_2022_0017_B
🏭
Vipo
2⚙️
Vipo HTP - Jet Fire
source: dnv-approval-finder
model_number: TAF00000MU
⚙️
ELASTOPIPE Fire Resistant (FR) and ELASTOPIPE Fire and Oil Resistant (FOR) plastic piping systems. Fire Endurance Standard: Level 3 (L3) and Level 3 Wet/Dry (L3 W/D).
source: uscg-cgmix
model_number: 164.141/38/0
🏭
Weihai Bosheng Advanced Materials
2⚙️
BSCF-A60-96B Type Class A-60 Fire-resistant Bulkhead
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000B5X
⚙️
BSCF-A60-96D Type Class A-60 Fire-resistant Deck
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000B5Y
🏭
Westex Carpets
2⚙️
100% Wool Loop Pile Broadloom Carpet; Boucle, Cable, Barrington
source: uk-mca
model_number: 53108
⚙️
80/20 Wool/Nylon Cut Pile Broadloom Carpet; Major, Ultima, Graphics, Pinnacle, Crest, Penultima, Supreme, Prestige, Westend, Designer Point, Designer Stripe
source: uk-mca
model_number: 53109
🏭
Zhejiang Hongjing Textile Technology
2⚙️
Certificate MEDD000024X
imo_approved: True
source: dnv-approval-finder
model_number: MEDD000024X
⚙️
HJS1001-6, HJS2001-3, HJS3001-9
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000075F
🏭
Zhejiang Orientx Fire Safety Equipment
2⚙️
Portable Fire Extinguishers: P1; PG1; P2; PG2; PG2A; PG2K; EP2N; PG3K; PG4A; PG4R; PG6A; PG6K; PG9A; PG9K; PG6R; PG9R; PC6; PC9; PC12; PG6H; PG6J; PG9B; PG12; PK6B-L; PK6S-L; PK12S-L; MP9N; F3K; F6K; F9K; FC9; F6R; F9R; F6; F9; F6H; F9H; F6(S); F9(S); MF9N; W3F; W6K; W9K; W6R; W9R; W9; W9J; Orex K2-01; Orex K2-02; Orex K5-01; Orex K5-02; K2; K5; OCE2-LWB117; OCE5-LWB152; K2C; K5C; WF2; WF3; WF6; WF9; W2H;
source: uk-mca
model_number: 23/CN-UK/5073-1-Rev.0
⚙️
Mobile Fire extinguishers : MTZ10; MTZ10A; P25A; P30A; P50A; P50B; P50C; F25; F50; F50A; F50B
source: uk-mca
model_number: 23/CN-UK/5074-0-Rev.0
🏭
2 JCP
1⚙️
A60-HD Acoustic Fire Door
source: dnv-approval-finder
model_number: TAF00001S5
🏭
Acotec
1⚙️
"Humidur Char" - Jet fire
source: dnv-approval-finder
model_number: TAF00001JZ
🏭
Aker Solutions
1⚙️
Aker Solution Fire Box, Powered by Favuseal
source: dnv-approval-finder
model_number: TAF000014T
🏭
Armacell Italia
1⚙️
ArmaComfort Barrier P
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00008TN
🏭
AVD Fire
1⚙️
LithEx AVD2 - 2 litre (AVD premix) water based, stored pressure extinguisher.
source: uk-mca
model_number: BSI/UK/3.38/824806
🏭
AWG Fittings
1⚙️
Nozzles for fire fighting
imo_approved: True
source: dnv-approval-finder
model_number: MEDD00000V2
🏭
Axalta Boya Sistemleri Sanayi ve Ticaret Limited Sirketi
1⚙️
ALESTA EP® / TEODUR EP® (max. application rate 120 g/m²)
source: uk-mca
model_number: SMS.UK.D/139193/A.0
🏭
Axalta Powder Coating Systems UK
1⚙️
ALESTA EP® / TEODUR EP® (max. application rate 120 g/m²)
source: uk-mca
model_number: SMS.UK.D/139194/B.0
🏭
Baas Component
1⚙️
A-0 class Rectangular Fire Damper of type EFGD
source: dnv-approval-finder
model_number: TAF00001SX
🏭
Beck Products Ltd t/a Beck Group
1⚙️
Proguard IMO R.W. Antislip Carpet Film White
source: uk-mca
model_number: WCL1121/MER1041QARev.1
🏭
Beijing Pearl Carpet
1⚙️
Handtufted Carpet
57031000
source: uk-mca
model_number: 53152
🏭
Bijlard International
1⚙️
Fire Resisting Material – Type: “Bijlard Spuitlijm rood/transparent” universal sprayable contact glue (Bijlard Spuitlijm rood/transparent)
source: uk-mca
model_number: LR23215487UKMB
🏭
BOSTIK Usine d'Avelin
1⚙️
Flexible adhesive material, type MSR-BC (maximum application rate: 124 g/m²)
source: uk-mca
model_number: SMS.UK.D/30018/A.0
🏭
Bristol Uniforms
1⚙️
Bristol Fleet Firefighting Suits: FS17 & FS18; (L)BT/xx & (L)TBT/xx; (L)EAn/xx & (L)TEAn/xx
source: uk-mca
model_number: 53036
🏭
Brødrene AA
1⚙️
Brødrene Aa fire restricting material
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006AZ
🏭
Carboline Global
1⚙️
Pyroclad X1 - Jet fire
source: dnv-approval-finder
model_number: TAF00000G7
🏭
Carpenter
1⚙️
EXTRASTEP
source: uk-mca
model_number: 1121WCL/MER0255QARev.2
🏭
Cavalier Carpets
1⚙️
Carpet floor covering; Tufted
source: uk-mca
model_number: 53011/1
🏭
CheckFire
1⚙️
FX-CO-005-ACF - 5kg Carbon Dioxide Fire Extinguisher
source: uk-mca
model_number: BSI/UK/3.2/815542
🏭
Cosentino Industrial SAU
1⚙️
DEKTON
source: uk-mca
model_number: 75036/A1 UK
🏭
Daemmstoff Industrie Korea
1⚙️
Fire Stop System A-119N
source: dnv-approval-finder
model_number: TAE00003GY
🏭
Dalian Luminglight
1⚙️
After-Glow Luminescent Secure Indication System, Fire Safety Signs
source: dnv-approval-finder
model_number: TAE000035X
🏭
DSEI
1⚙️
Class A0-1 fire door
source: dnv-approval-finder
model_number: TAF00001GV
🏭
DUX INTERIORES
1⚙️
Dux Dynamic 19 / Dux Inspiration 6006/8008
source: uk-mca
model_number: 164.142\1121\WCL MER0601QA
🏭
Edmund Bell &
1⚙️
Curtain 6998/MS2/237
source: uk-mca
model_number: 53139
🏭
Egger Kunststoffe
1⚙️
Fire Resisting Material Type: “EGGER Schichtstoff (EGGER laminate); EGGER Schichtstoff mit farbigem Kern (EGGER laminate coloured core); EGGER Schichtstoff lackierfaehig (EGGER painting grade)”; decorative veneers (EGGER Schichtstoff (EGGER laminate); EGGER Schichtstoff mit farbigem Kern (EGGER laminate coloured core) and EGGER Schichtstoff lackierfaehig (EGGER painting gade).)
source: uk-mca
model_number: LR23383184UKMD
🏭
ELAFLEX HIBY
1⚙️
ELAFLEX Expansion Joint ERV-GS and ERV-GS HNBR, ERV with fire sleeve type FSH
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000B2Z
🏭
ENGIE Axima Germany
1⚙️
Fire Smoke Damper FRKL-E
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00001EK
🏭
Entel UK
1⚙️
DT844FF
DT944FF
DT842
DT844
DT942
DT944 (Entel)
source: uk-mca
model_number: P133 MER
🏭
Etex Building Performance
1⚙️
B-15 Class Bulkhead with "PROMARINE(R)-450T" (19 mm) / B-0 Class Bulkhead with "PROMARINE(R)-640T" (12,7 mm) / B-15 Class Bulkhead with "PROMARINE(R)-640T" (2x12,7 mm) / B-15 Class Bulkhead with "PROMARINE(R)-640T" (19 mm) / / For junction means, see §1
source: uk-mca
model_number: 77496/A0 UK
🏭
European Safety Systems
1⚙️
AL100X, AL105NX, AL112NX, AL121X series of products approved as an audible signal notification device for use in Category 1, 2, and 3 spaces. Products include a supplemental strobe.
source: uscg-cgmix
model_number: 161.002/69/0
🏭
Fire Eater
1⚙️
INERGEN Fire Extinguishing System
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00001WD
🏭
Fireboy-Xintex UK Operations
1⚙️
Fixed Gas Fire Extinguishing System (Fireboy FES (NOVEC 1230 or equivalent FK-5-1-12 extinguishant) Total Flood Fire Suprresion 25 bar System)
source: uk-mca
model_number: LR23390754UKMB
🏭
FirePro Systems
1⚙️
Aerosol Fire Extinguishing Units with dry condensed extinguishing agent, Fire Class A & B Models - FP20S, FP20SE, FP40S, FP80S, FP100S, FP-100EX, FP200S, FP-200EX, FP500S, FP-500EX, FP1200, FP1200S, FP-1200EX, FP2000, FP2000S, FP-2000EX, FP3000, FP3000S, FP-3000EX, FP4200T/TS, FP-4200EX, FP5700, FP5700S & FP-5700EX.
source: uk-mca
model_number: BSI/UK/3.46/560436
🏭
Fitech Engineering
1⚙️
HIGH PRESSURE CO2 FIRE EXTINGUISHING SYSTEM
source: dnv-approval-finder
model_number: TAF000006B
🏭
FlamePro Global
1⚙️
Jacket 770, Trousers 775, Jacket 670, Trousers 675
source: uk-mca
model_number: 53046/2
🏭
Florprotec
1⚙️
Tacbac FR
source: uk-mca
model_number: 1121\WCL MER0506QARev.1
🏭
Forbo Flooring Coral
1⚙️
CORAL MARINE FR: Tufted broadloom carpet – 60% wool/40% Polyamide – FR latex backing
200-230g/m² _ 0.4mm (CORAL MARINE FR)
source: uk-mca
model_number: UK_2023_0062_B
🏭
Formica IKI
1⚙️
Formica High Pressure Laminates: / HGP, VGP, LTP (thickness 0.6~0.8 mm) / HGF (thickness 0.8~1.2 mm)
source: uk-mca
model_number: 74060/A0 UK
🏭
Fritz Egger GmbH & Co. OG
1⚙️
Fire-Resisting Material – Type: "Egger Laminate XL" (Egger Laminate XL)
source: uk-mca
model_number: LR23405274UKMB
🏭
G. Theodor Freese
1⚙️
TEFROTEX® VISCOELASTIC Thix
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004SF
🏭
Gabriel
1⚙️
100% Trevira CS fabrics – “Step” / “Step Melange
source: uk-mca
model_number: 164.144\1121\WCL MER0431TE
🏭
GENTAŞ DEKORATİF YÜZEYLER SANAYİ ve TİCARET A.Ş
1⚙️
High Presssure Decorative Laminates - HGS/VGS
source: uk-mca
model_number: 164.117\1121\WCL MER0600QA
🏭
GERFLOR SAS
1⚙️
Perm' Adhesive
source: uk-mca
model_number: WCL1121/MER0530QARev.1
🏭
Ghibson Italia
1⚙️
BVHD Wafer type (fire safe with RTFE/inconel seats), BLHD Lug type (fire safe with RTFE/inconel seats)
source: dnv-approval-finder
model_number: TAP00000KG
🏭
GW SPRINKLER
1⚙️
Water-based fixed local fire extinguishing system for category A machinery spaces - Type "GW Water Mist System Model M5".
source: uk-mca
model_number: 77024/A0 UK
🏭
H.B. Fuller Adhesives France SAS
1⚙️
Köratac FL 104 (maximum application rate 31.4 g/m²)
source: uk-mca
model_number: SMS.UK.D/132506/A.0
🏭
Haes Technologies
1⚙️
ESEN-2MAR
ESEN-4MAR
ESEN-8MAR
ESEN-12MAR
ESEN-R-12MAR
source: uk-mca
model_number: 0832-UKCA-MED-F1015
🏭
Hangzhou Deqi Carpet
1⚙️
Handtufted Carpet / 57031000
source: uk-mca
model_number: 53156
🏭
Hankuk Miboo
1⚙️
A-0 FIRE DAMPER
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00001GM
🏭
Harvik Rubber Industries
1⚙️
Art 9687L - Firefighter Boot
source: uk-mca
model_number: 0843-MED-0208
🏭
HKS GmbH industrieller Hersteller von Kompensatoren und Schläuchen
1⚙️
Flame resistant PTFE hose assembly with fire proof sleeves
imo_approved: True
source: dnv-approval-finder
model_number: 6195414 HH
🏭
Honeywell International
1⚙️
Fire alarm control panels XLS120(E)(C) and XLS140-2(E)
source: uscg-cgmix
model_number: 161.002/B50/0
🏭
HS KB Valve
1⚙️
Fire Safe Butterfly Valves PN6, PN10, PN16, PN25, Class 150
source: dnv-approval-finder
model_number: TAP00001C3
🏭
Hubei Meisheng Yaheng New Material Technology
1⚙️
A60-II Floating Fire floor
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000BN6
🏭
Huizhou WeiKang New Building Materials
1⚙️
Luvanto FR Marine LVT Flooring
source: uk-mca
model_number: WCL1121/MER0380QARev.1
🏭
Insulcon
1⚙️
Wearflex® Q-Fire Sealing System
source: dnv-approval-finder
model_number: TAF00000M0
🏭
Interdam Holding
1⚙️
Fire Resisting Single Leaf Hinged Door – Type: “NADAM 4” Restricted Application: Door to be fully locked at all times (NADAM 4)
source: uk-mca
model_number: LR2532688UKMB
🏭
Interfloor
1⚙️
TALVMULTIFIT
source: uk-mca
model_number: 164.117\1121\WCL MER0602QA
🏭
Jansen Tore
1⚙️
Jansen A-0 Rolling Fire Shutter (JA-0 RFS)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004VW
🏭
Jiangyin Huangshan Marine Fitting
1⚙️
Class A-60 fire hatch cover,
source: dnv-approval-finder
model_number: TAF0000093
🏭
Jingjiang Jinzhou Marine Equipment
1⚙️
Class A-60 Fire Side Scuttle
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00005XK
🏭
Johnson Controls International Korea
1⚙️
Fixed high-pressure CO2 fire extinguishing system
source: dnv-approval-finder
model_number: TAF00000ZX
🏭
KwangLim Marine Tech
1⚙️
"A0-KL-01" A-0 Class Fire Resistance Steel Door
source: dnv-approval-finder
model_number: TAF00001BU
🏭
Lano Carpets
1⚙️
Walk Of Fame
source: uk-mca
model_number: 164.117\1121\WCL MER0333QA
🏭
Lexidor
1⚙️
Decorative veneer material - Type "Lexidor Sign System - Lexidor Decor" multi-layer heterogeneous covering (Lexidor Sign System - Lexidor Decor)
source: uk-mca
model_number: LR25280877UKMB
🏭
Luyang Energy-saving Materials
1⚙️
Class A60 Deck - LYBST - Basalt Rock Wool Board
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004GR
🏭
LX HAUSYS (ULSAN FACTORY)
1⚙️
LX Hausys Interior Film - REATEC_LXH (also named as STRATAFLEX_LXH)
source: uk-mca
model_number: 82500/A0 UK
🏭
MANDALS A/S, A Michelin Group
1⚙️
Mandals Mertex
source: uk-mca
model_number: 79119/A0 UK
🏭
Marine Systems Technology
1⚙️
A-60 DOOR SINGLE LEAF HINGED - Fire Doors on High Speed Craft – Type: “MST 60 Minute Door for HSC Code” or “A-60 Door for SOLAS, Chapter II-2” (A60 Door Single Leaf Hinged)
source: uk-mca
model_number: LR23293450UKMB
🏭
Matre Maskin
1⚙️
Deck Integrated Fire Fighting — Pop-up Nozzle
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00003WA
🏭
MCT Brattberg
1⚙️
RGS series penetration seals approved for installation in H-class bulkheads.
source: uscg-cgmix
model_number: 164.140/7/0
🏭
Moflash Signalling
1⚙️
YODALARM - YO3 Series (YA30 AC/DC), YO4 Series (YA40/YL40 AC/DC, YO5 Series (YA50/YL50 AC/DC), YO8 Series (YA80/YL80/YA8S/YL8S AC/DC)
source: uk-mca
model_number: BSI/UK/3.53/738807
🏭
Motorola Solutions Systems Polska Sp. z.o.o
1⚙️
DP4401 Ex, PBE502BEEx
DP4801 Ex, PBE502HEGEx
XiR P8668 Ex
XiR P8608 Ex
DGP 8550EX
DGP 8050EX
source: uk-mca
model_number: BABT-UKMA000027
🏭
Nanjing Hengxinda
1⚙️
automatic round fire damper type HCF
imo_approved: True
source: dnv-approval-finder
model_number: 4244902 Lux
🏭
Nanjing Lishui YiSheng Ship Fittings Factory
1⚙️
A-0 Fire Door (Type: 124YS01-20-00)
source: dnv-approval-finder
model_number: TAF00000WA
🏭
Navutec
1⚙️
Deck Integrated Fire Fighting (DIFF) – Nozzle /POP-UP 20
source: dnv-approval-finder
model_number: TAF00001NJ
🏭
Niikura Kogyo
1⚙️
N-NHV-SCS-65, N-NHV-SCS-80
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006JH
🏭
Ningbo Tecson Sealing Technology
1⚙️
Fire Safe Gasket "HPG-FS"
source: dnv-approval-finder
model_number: TAP00002TW
🏭
NK Co., Ltd. (No.1 Factory)
1⚙️
IG-541 (inert gas) Fire-Extinguishing System
source: dnv-approval-finder
model_number: TAF000012M
🏭
North Sea Ventilation & Air Conditioning
1⚙️
H-120 FIRE DAMPER TYPE FGS-01
source: dnv-approval-finder
model_number: TAF00000SD
🏭
PANELFA
1⚙️
Fire door Class A-60 - DA60001
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00001GS
🏭
Paroc
1⚙️
Non-combustible insulating materials made of stone wool formed as slabs, mats & pipes sections.
source: uk-mca
model_number: SMS.UK.D/94701/A.1
🏭
Pfannenberg
1⚙️
Fire alarm devices - sounders
source: dnv-approval-finder
model_number: MERB00002BH
🏭
Puma Fire Products
1⚙️
DUPLEX ST PRD (Pressure Relief Fire Damper)
source: dnv-approval-finder
model_number: TAF000013J
🏭
Remitite
1⚙️
Flexible Fire Seal: Remitite EDT-629
source: dnv-approval-finder
model_number: TAF00000NJ
🏭
Respirex International
1⚙️
WORKMASTER ISOTEC BOOT / B01200 to B01210 & B01215 to B01216
source: uk-mca
model_number: 53168
🏭
Saint Gobain Isover Benelux B.V
1⚙️
Technipanel 20 and TECHSLAB 2.0
source: uk-mca
model_number: WCL1121/MER0109QARev.1
🏭
SAINT-GOBAIN BYGGEVARER
1⚙️
Weberfloor 4686N Marine Extra Light
source: dnv-approval-finder
model_number: TAF000022T
🏭
SAMHWA PAINTS INDUSTRIAL
1⚙️
CHARREX PFP-1000 - Jet fire
source: dnv-approval-finder
model_number: TAF000007A
🏭
Sanglier
1⚙️
Tuskbond Gold G500
source: uk-mca
model_number: 164.112\1121\WCL MER0485QA
🏭
Schauenburg Industrietechnik
1⚙️
Fire Sleeve F88SC with Hoses Type 2TE; 3TE; 2SN
source: dnv-approval-finder
model_number: TAP0000225
🏭
Schindler
1⚙️
Double-leaf hinged fire door A30 for lift applications
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000087J
🏭
Sealy United Kingdom
1⚙️
Sprung and foam core mattresses, and mattress toppers
SEA/IMO/001; SEA/IMO/002; SEA/IMO/003; SEA/IMO/004; SEA/IMO/007
source: uk-mca
model_number: 53016/1
🏭
SEC SYSTEMS
1⚙️
A' & 'B' Class Divisions Fire Integrity: 'B' Class Divisions
source: uk-mca
model_number: LR2516464UKMD
🏭
SEC Systems
1⚙️
Fire Resisting B Class Panel System – Type: “S/B-13-060 zm.b” ("S/B-13-060 zm.b” B-15 Bulkhead)
source: uk-mca
model_number: LR2538282UKMB
🏭
SENTURA GROUP
1⚙️
Mobile Fire extinguishers
source: uk-mca
model_number: 23/GB-UK/1021-0-Rev.0
🏭
SEVO Systems
1⚙️
SEVO 1230 Clean Agent Fire Suppression System / FFT Clean Agent Fire Suppression System
source: dnv-approval-finder
model_number: TAF000005Y
🏭
Shanghai Huoke New Material
1⚙️
Fire Resisting Material - Silicone Based Adhesive applied on metallic sheet (HK-3000' type Marine Fireproof Sealing Adhesive)
source: uk-mca
model_number: LR2400741UKMB
🏭
SHANGHAI SHENTE MACHINERY MANUFACTURING
1⚙️
Class A-0 Marine Fire Door type SST385
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000024J
🏭
Shengyuan Carpet Group
1⚙️
Axminster Carpet S266P0707/28-S388P1307/67
source: uk-mca
model_number: 53150
🏭
Specified Technologies
1⚙️
STI Marine fire stop device
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004AT
🏭
Stengel
1⚙️
Class B-15 Fire Door type: StNzT21
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007G0
🏭
Straub Werke
1⚙️
STRAUB-GRIP, STRAUB-GRIP FF (FIRE FENCE)
source: dnv-approval-finder
model_number: TAP00001JE
🏭
Sun Chemical
1⚙️
Sunjet Crystal UV Curing Ink (Yellow, Magenta, Light Magenta, Cyan, Light Cyan, Black, White)
source: uk-mca
model_number: BSI/UK/3.18b/807834
🏭
Survitec Survival Craft
1⚙️
Model SC985FA, 9.85 m x 3.06 m x 3.30 m, 81-person, totally enclosed, fire-protected lifeboat of fiberglass reinforced plastic construction.
source: uscg-cgmix
model_number: 160.135/107/0
🏭
Suzhou Yibo Industry & Trading
1⚙️
YB-3 Type class A-60 fire Deck
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000125
🏭
Swegon Air Management
1⚙️
A-60 Marine Fire Damper
source: dnv-approval-finder
model_number: TAF00000H9
🏭
Taicang Fushi Machinery & Equipment
1⚙️
Rectangular fire damper type SRFD
imo_approved: True
source: dnv-approval-finder
model_number: 4778403 Lux
🏭
Taicang Haichang
1⚙️
Marine fire damper type TFA-JU
imo_approved: True
source: dnv-approval-finder
model_number: 1584200 Lux
🏭
Taicang Yongming Paien Machine
1⚙️
A-60 fire damper for use in ventilation ducts penetrating decks when insulated in an approved manner
imo_approved: True
source: dnv-approval-finder
model_number: 4003601 Lux
🏭
Taixing Traffic Machinery Facilities Factory
1⚙️
263TJS008 - Class A60 fire hatch cover
source: dnv-approval-finder
model_number: TAF00001VF
🏭
Taizhou Sanjiang Fire Control Equipment
1⚙️
Fire hose 45 mm (1 3/4") x 20 m and Fire hose 52 mm (2") x 20 m
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00005CF
🏭
Tanktech
1⚙️
Total Water Mist Fire Fighting System: X-MIST
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000044D
🏭
TERMOLAN - Isolamentos Termo- Acústicos
1⚙️
Rocterm/Ecoterme/Rocterm+ insulation type:"PI40 - PI180", "PI40AL - PI180AL", "R70 - R125", "MN70 - MN125", "MA70 - MA125", "CQ70 - CQ120" , "CQ70AL - CQ120AL"
source: uk-mca
model_number: MERB0001N1J
🏭
The Amtico
1⚙️
Material Having Low Flame Spread Characteristics and Not Capable of Producing
Excessive Smoke & Toxic Products of Combustion ("Amitco marine safety")
source: uk-mca
model_number: LR2675044UKMB
🏭
The Wilton Carpet Factory
1⚙️
Rugs Textile Floor Covering / Graphics 1000, Graphics 1200, Graphics 1400, Graphics 1600
source: uk-mca
model_number: 53155
🏭
Thrane & Thrane
1⚙️
SAILOR 3965, McMurdo R8F
source: uk-mca
model_number: BABT-UKMA000090
🏭
Tyco Building Services Products B.V
1⚙️
SYSTEM 913 / Local Application Fire Fighting System for category A machinery spaces / Type "Aquamist Model AM 15 water mist nozzle"
source: uk-mca
model_number: 74290/A0 UK
🏭
Tyco Fire & Security Czech Republic s.r.o
1⚙️
P80SB-M
source: uk-mca
model_number: 0832-UKCA-MED-F1014
🏭
VTI Fire Products(Shanghai)
1⚙️
VTI DCP Fire Suppression System
imo_approved: True
source: dnv-approval-finder
model_number: MEDB0000831
🏭
VTI Marine Equipments (Shanghai)
1⚙️
Fixed high-pressure CO2 fire extinguishing system
source: dnv-approval-finder
model_number: TAF00000KV
🏭
Witt & Sohn Aktiengesellschaft
1⚙️
Fire Dampers - Single Bladed Circular Fire Damper (“IGW fire Damper, BK250, BK315 up to BK1800” for use in A-Class Steel Decks)
source: uk-mca
model_number: LR22413183UKMB
🏭
WITTUR
1⚙️
SERIES 3201-PEGASUS TY.01/C and 3201-HYDRA TY.01/C DOORSETS in insulated fire-rated version, classified A-0
imo_approved: True
source: dnv-approval-finder
model_number: 2061011 HH
🏭
Wolman Wood and Fire Protection
1⚙️
SikaSeal-641 Fire Coating
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000095X
🏭
You Shin Dan Yeol Co., Ltd. Factory No.1
1⚙️
PET Film + ALCSM + Mineral wool
source: dnv-approval-finder
model_number: TAF00000TC
🏭
Zhejiang Pusen New Material Technology
1⚙️
PSLB Type Glass Fiber Aluminium Foil Fabric + PSJ Type Flame Retardant White Glue (Fire to the Front Face & Fire to the Back Face)
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006B6
🏭
Øglænd System
1⚙️
Øglænd's passive fire protection system FireSys, Powered by Favuseal®
source: dnv-approval-finder
model_number: TAE00004W9