Wird verarbeitet…
OSM

CO₂ Fixed System (Engine Room + Cargo)

critical IMO Required 5 / 887 Modelle (Inspector)
Fixed CO₂ total-flooding fire extinguishing system per SOLAS II-2.
8760h
Service Interval

Typical Manufacturers

Kidde Viking Unitor Marioff
Inspector Mode Show All 5 / 887 with inspector value

2 Hersteller · 5 Modelle

🏭

Kidde

4 ✓ 4 verifiziert
⚙️
Kidde CO₂ Total Flooding System ✓ verifiziert Inspector
Engine room / cargo hold coverage · Fire Suppression / Detection
Common Failures:
  • • Pilot cylinder pressure loss
  • • Distribution valve seat leak
  • • Cable-operated release mechanism seizure
Service: Cylinder weighing every 2 years. Pilot cylinder hydrostatic test every 10 years. Full system function test at annual survey.
Spares: Kidde: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.
⚙️
Kidde CO2 Bulk System ER ✓ verifiziert
equipment_type: fire_suppression
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.7
solas_type: SOLAS
engine room bulk CO2
⚙️
Kidde CO2 Cylinder Bank System ✓ verifiziert
equipment_type: fire_suppression
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.7
solas_type: SOLAS
cylinder bank CO2
⚙️
Kidde CO2 Cargo Hold System ✓ verifiziert
equipment_type: fire_suppression
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.7
solas_type: SOLAS
cargo hold CO2
🏭

Unitor

1 ✓ 1 verifiziert
⚙️
Unitor CO₂ Fixed Fire Extinguishing System ✓ verifiziert Inspector
Modular 45 kg cylinders · Fire Suppression / Detection
Common Failures:
  • • Release cabinet interlock failure
  • • Nozzle blockage by paint/corrosion
  • • Time delay mechanism malfunction
Service: Annual function test of release mechanism. Nozzle inspection at dry-dock. Alarm/ventilation interlock test quarterly.
Spares: Unitor: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.